Non-enzymatic glucose sensor using nanostructured copper oxide thin films deposited by spray pyrolysis

被引:11
作者
Martinez-Saucedo, G. [1 ]
Ugalde-Reygadas, M. [2 ]
Pena, J. J. Alcantar [1 ]
Lastra-Medina, G. [1 ,2 ]
Marquez-Marin, J. [2 ]
Torres-Delgado, G. [2 ]
Castanedo-Perez, R. [2 ]
Chavez-Urbiola, I. R. [1 ]
机构
[1] Ctr Ingn & Desarrollo Ind, Ave Playa Pie de la Cuesta 702, Santiago De Queretaro 76125, Queretaro, Mexico
[2] IPN, Unidad Queretaro, Ctr Invest & Estudios Avanzados, Queretaro 76230, Qro, Mexico
关键词
Glucose sensor; Biosensor; Thin film; Copper oxides; NANOWIRE ARRAYS; NANOPARTICLES; ELECTRODE;
D O I
10.1016/j.surfin.2023.102702
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Thin-film thickness effect on glucose sensitivity for a non-enzymatic sensor is affected by two main factors, film ' s conductivity, and roughness. The thin-film thickness effect is studied with copper oxide films grown by spray pyrolysis. The film is deposited with thickness in the 83 <= tau film <= 892 nm range on a nickel electrode and employed for glucose sensing in a three-electrode system as a working electrode. As the film thickness increases up to 434 nm, the signal stability and sensibility improve. For a greater thickness, the glucose sensibility starts to decrease smoothly. The sensibility increment from the thinnest film to our best condition is twofold from 0.25 to 0.47 mAmM-1/cm2, and a lineal behavior is observed for a wide glucose concentration range of 0-8 mM. This work shows that a simple solution-based technique such as spray pyrolysis can be employed to obtain functional glucose sensors.
引用
收藏
页数:7
相关论文
共 34 条
  • [1] [Anonymous], 2021, International Diabetes Federation, V10th, DOI DOI 10.1016/J.DIABRES.2013.10.013
  • [2] Non-Enzymatic Glucose Sensors Involving Copper: An Electrochemical Perspective
    Aun, Tan Tiek
    Salleh, Noordini Mohamad
    Ali, Umi Fazara Md
    Manan, Ninie Suhana Abdul
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2023, 53 (03) : 537 - 593
  • [3] Burleson W., 2014, Secur. Priv. Implant. Med.Devices, P1, DOI [10.1007/978-1-4614-1674-6, DOI 10.1007/978-1-4614-1674-6]
  • [4] Highly sensitive nonenzymatic glucose sensor based on electrospun copper oxide-doped nickel oxide composite microfibers
    Cao, Fei
    Guo, Shu
    Ma, Huiyan
    Yang, Guocheng
    Yang, Shengxue
    Gong, Jian
    [J]. TALANTA, 2011, 86 : 214 - 220
  • [5] ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
    CLARK, LC
    LYONS, C
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) : 29 - &
  • [6] Development of Cu2O/Carbon Vulcan XC-72 as non-enzymatic sensor for glucose determination
    El Khatib, K. M.
    Hameed, R. M. Abdel
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (08) : 3542 - 3548
  • [7] A Practical Beginner's Guide to Cyclic Voltammetry
    Elgrishi, Noemie
    Rountree, Kelley J.
    McCarthy, Brian D.
    Rountree, Eric S.
    Eisenhart, Thomas T.
    Dempsey, Jillian L.
    [J]. JOURNAL OF CHEMICAL EDUCATION, 2018, 95 (02) : 197 - 206
  • [8] ELHALEEM SMA, 1981, J ELECTROANAL CHEM, V117, P309
  • [9] An ultrasensitive non-enzymatic amperometric glucose sensor based on a Cu-coated nanoporous gold film involving co-mediating
    Guo, Man-man
    Wang, Peng-shu
    Zhou, Chao-hui
    Xia, Yue
    Huang, Wei
    Li, Zelin
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 203 : 388 - 395
  • [10] A novel CuO/TiO2 hollow nanofiber film for non-enzymatic glucose sensing
    Guo, Qiaohui
    Zhang, Man
    Li, Xia
    Li, Xinrui
    Li, Haoran
    Lu, Yuanjie
    Song, Xiaoxi
    Wang, Li
    [J]. RSC ADVANCES, 2016, 6 (102): : 99969 - 99976