A label-free dual immunosensor for the simultaneous electrochemical determination of CA125 and HE4 biomarkers for the early diagnosis of ovarian cancer

被引:23
作者
Bilgi Kamac, Melike [1 ]
Altun, Muhammed [1 ]
Yilmaz, Merve [1 ]
Sezginturk, Mustafa Kemal [2 ]
机构
[1] Cankiri Karatekin Univ, Fac Sci, Chem Dept, TR-18100 Cankiri, Turkiye
[2] Canakkale Onsekiz Mart Univ, Fac Engn, Bioengn Dept, Canakkale, Turkiye
关键词
CA125; HE4; Simultaneous determination; Dual electrochemical immunosensors; Ovarian cancer; ANTIGEN; 125; BIOSENSOR; DISEASE; PROTEIN; POINT; PREDICTION; MULTIPLE; MARKER; SIGNAL; RISK;
D O I
10.1007/s00216-023-04569-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The blood levels of cancer antigen 125 (CA125) and human epididymal secretory protein 4 (HE4) are measured in the diagnosis and progression monitoring of ovarian cancer (OC), and the Risk of Ovarian Malignancy Algorithm (ROMA) score% values are calculated for cancer risk assessment. For the first time, disposable dual screen-printed carbon electrodes modified with reduced graphene oxide, polythionine, and gold nanoparticles were used to fabricate label-free electrochemical dual CA125-HE4 immunosensors for the sensitive, fast, and practical simultaneous determination of CA125 and HE4. DPV and SWV methods were used to simultaneously determine antigens in two different linear ranges (1-100 pg mL(-1) and 1-50 ng mL(-1)). High sensitivity, low LOD, and LOQ were obtained for two linear ranges with a correlation coefficient above 0.99. The application stability of the dual CA125-HE4 immunosensors was determined as 60 days, and the storage stability was determined as 16 weeks. The dual immunosensors exhibited high selectivity in eight different antigen mixtures. The reusability of the dual immunosensors has been tested up to 9 cycles. ROMA score% values for pre-menopausal and post-menopausal status were calculated using the concentration of CA125 and HE4 in the blood serum and assessing OC risk. The disposable dual immunosensors can be used in point-of-care tests for rapid and practical simultaneous determination of CA125 and HE4 with high selectivity, sensitivity, and repeatability.
引用
收藏
页码:1709 / 1718
页数:10
相关论文
共 49 条
[1]   Dopamine biosensor based on screen-printed electrode modified with reduced graphene oxide, polyneutral red and gold nanoparticle [J].
Altun, Muhammed ;
Kamac, Melike Bilgi ;
Bilgi, Alper ;
Yilmaz, Merve .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2020, 100 (04) :451-467
[2]   Highly selective and sensitive sandwich immunosensor platform modified with MUA-capped GNPs for detection of spike Receptor Binding Domain protein: A precious marker of COVID 19 infection [J].
Aydin, Elif Burcu ;
Aydin, Muhammet ;
Sezginturk, Mustafa Kemal .
SENSORS AND ACTUATORS B-CHEMICAL, 2021, 345
[3]   The development of an ultra-sensitive electrochemical immunosensor using a PPyr-NHS functionalized disposable ITO sheet for the detection of interleukin 6 in real human serums [J].
Aydin, Elif Burcu ;
Aydin, Muhammet ;
Sezginturk, Mustafa Kemal .
NEW JOURNAL OF CHEMISTRY, 2020, 44 (33) :14228-14238
[4]   A sensitive and disposable electrochemical immunosensor for detection of SOX2, a biomarker of cancer [J].
Aydin, Elif Burcu ;
Sezginturk, Mustafa Kemal .
TALANTA, 2017, 172 :162-170
[5]   Label-Free Electrochemical Immunosensor for Ultrasensitive Detection of Carbohydrate Antigen 125 Based on Antibody-Immobilized Biocompatible MOF-808/CNT [J].
Biswas, Sudip ;
Lan, Qingchun ;
Xie, Yao ;
Sun, Xin ;
Wang, Yang .
ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (02) :3295-3302
[6]   Alzheimer's disease: Development of a sensitive label-free electrochemical immunosensor for detection of amyloid beta peptide [J].
Carneiro, Pedro ;
Loureiro, Joana ;
Delerue-Matos, Cristina ;
Morais, Simone ;
Pereira, Maria do Carmo .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 :157-165
[7]   Non-sensitive axis feedback control of test mass in full-maglev vertical superconducting gravity instruments [J].
Chen, Daiyong ;
Liu, Xikai ;
Wang, Lulu ;
Chen, Liang ;
Liu, Xiangdong .
MEASUREMENT, 2022, 189
[8]   A label-free electrochemical immunosensor based on a gold-vertical graphene/TiO2 nanotube electrode for CA125 detection in oxidation/reduction dual channels [J].
Chen, Zehua ;
Li, Bingbing ;
Liu, Jinbiao ;
Li, Hongji ;
Li, Cuiping ;
Xuan, Xiuwei ;
Li, Mingji .
MICROCHIMICA ACTA, 2022, 189 (07)
[9]   An impedimetric biosensor system based on disposable graphite paper electrodes: Detection of ST2 as a potential biomarker for cardiovascular disease in human serum [J].
Demirbakan, Burcak ;
Sezginturk, Mustafa Kemal .
ANALYTICA CHIMICA ACTA, 2021, 1144 :43-52
[10]   A novel ultrasensitive immunosensor based on disposable graphite paper electrodes for troponin T detection in cardiovascular disease [J].
Demirbakan, Burcak ;
Sezginturk, Mustafa Kemal .
TALANTA, 2020, 213