SRTNet: Scanning, Reading, and Thinking Network for myocardial infarction detection and localization

被引:5
作者
Liu, Kaige [1 ]
Liu, Tong [1 ]
Wen, Dunwei [2 ]
Zang, Mujun [1 ]
Zhou, Shusen [1 ]
Liu, Chanjuan [1 ]
机构
[1] Ludong Univ, Dept Informat & Elect Engn, Yantai, Peoples R China
[2] Athabasca Univ, Sch Comp & Informat Syst, Athabasca, AB, Canada
基金
中国国家自然科学基金;
关键词
Myocardial infarction; Transformer; 12-lead electrocardiogram; Inter-patient; Convolutional neural network; CLASSIFICATION; MACHINE; ENERGY;
D O I
10.1016/j.eswa.2023.122402
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Objective: The incidence of myocardial infarction (MI) is increasing year by year and is characterized by a high mortality rate with rapid outbreaks. Electrocardiogram (ECG)-based detection and localization of myocardial infarction is susceptible to individual patient differences. We propose a new deep learning model to improve the detection and localization performance on different patient data. Methods: To address these issues, we propose SRTNet, a novel model with scanning, reading, and thinking modules, for MI detection and localization. The model learns ECG features from three different perspectives, namely, the scanning module for learning 12-lead ECG features, the reading module for learning the correlation features of different leads, and the thinking module for learning temporal dimension features. The model learned features contain both temporal and spatial ones that can alleviate overfitting individual differences. Results: In the experiments, we used 5-fold cross-validation in the PTB dataset to demonstrate the performance of SRTNet. The results show that SRTNet achieves the state-of-the-art performance. For detection performance, the accuracy is 99.25%, the sensitivity is 99.15%, the specificity is 98.58%, and the F1 score is 99.09%. For localization performance, the accuracy is 68.45%, the sensitivity is 61.82%, the specificity is 67.95% , and the F1 score is 60.50%. Conclusion: The experimental results show that SRTNet's multi-level feature learning method can detect and locate MI more accurately. Significance: Furthermore, the design of SRTNet provided a new perspective on clinical MI detection and localization systems.
引用
收藏
页数:11
相关论文
共 50 条
[31]   Application of artificial intelligence techniques for automated detection of myocardial infarction: a review [J].
Joloudari, Javad Hassannataj ;
Mojrian, Sanaz ;
Nodehi, Issa ;
Mashmool, Amir ;
Zadegan, Zeynab Kiani ;
Shirkharkolaie, Sahar Khanjani ;
Alizadehsani, Roohallah ;
Tamadon, Tahereh ;
Khosravi, Samiyeh ;
Kohnehshari, Mitra Akbari ;
Hassannatajjeloudari, Edris ;
Sharifrazi, Danial ;
Mosavi, Amir ;
Loh, Hui Wen ;
Tan, Ru-San ;
Acharya, U. Rajendra .
PHYSIOLOGICAL MEASUREMENT, 2022, 43 (08)
[32]   Myocardial infarction detection based on deep neural network on imbalanced data [J].
Mohamed Hammad ;
Monagi H. Alkinani ;
B. B. Gupta ;
Ahmed A. Abd El-Latif .
Multimedia Systems, 2022, 28 :1373-1385
[33]   Automated detection and localization of myocardial infarction using electrocardiogram: a comparative study of different leads [J].
Acharya, U. Rajendra ;
Fujita, Hamido ;
Sudarshan, Vidya K. ;
Oh, Shu Lih ;
Adam, Muhammad ;
Koh, Joel E. W. ;
Tan, Jen Hong ;
Ghista, Dhanjoo N. ;
Martis, Roshan Joy ;
Chua, Chua K. ;
Poo, Chua Kok ;
Tan, Ru San .
KNOWLEDGE-BASED SYSTEMS, 2016, 99 :146-156
[34]   Automatic detection and localisation of myocardial infarction using multi-channel dense attention neural network [J].
Qiang, Yupeng ;
Dong, Xunde ;
Yang, Yang .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 89
[35]   Automated interpretable detection of myocardial infarction fusing energy entropy and morphological features [J].
Han, Chuang ;
Shi, Li .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2019, 175 :9-23
[36]   Detection of myocardial infarction in 12 lead ECG using support vector machine [J].
Dohare, Ashok Kumar ;
Kumar, Vinod ;
Kumar, Ritesh .
APPLIED SOFT COMPUTING, 2018, 64 :138-147
[37]   Accurate detection of myocardial infarction using non linear features with ECG signals [J].
Sridhar, Chaitra ;
Lih, Oh Shu ;
Jahmunah, V. ;
Koh, Joel E. W. ;
Ciaccio, Edward J. ;
San, Tan Ru ;
Arunkumar, N. ;
Kadry, Seifedine ;
Rajendra Acharya, U. .
JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2021, 12 (03) :3227-3244
[38]   Multi-branch myocardial infarction detection and localization framework based on multi-instance learning and domain knowledge [J].
Li, Xinyue ;
Huang, Yangcheng ;
Ning, Yixin ;
Wang, Mingjie ;
Cai, Wenjie .
PHYSIOLOGICAL MEASUREMENT, 2024, 45 (04)
[39]   Automatic myocardial infarction detection in contrast echocardiography based on polar residual network [J].
Guo, Yanhui ;
Du, Guo-Qing ;
Shen, Wen-Qian ;
Du, Chunlai ;
He, Pei-Na ;
Siuly, Siuly .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 198
[40]   Localization of prior myocardial infarction by repolarization variables [J].
Vesterinen, Paula ;
Vaananen, Heikki ;
Stenroos, Matti ;
Hanninen, Helena ;
Korhonen, Petri ;
Tierala, Ilkka ;
Husa, Terhi ;
Makijarvi, Markku ;
Tolvonen, Lauri .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 124 (01) :100-106