Development of gold nanospikes-modified quartz crystal microbalance biosensor for prostate specific antigen detection

被引:3
|
作者
Sonklin, Thita [1 ]
Tongpeng, Suparat [1 ]
Munthala, Dhananjaya [1 ]
Suksaweang, Sanong [2 ]
Janphuang, Pattanaphong [3 ]
Bharti, Anu [4 ]
Mathur, Ashish [4 ]
Avasthi, Devesh Kumar [5 ]
Jiansirisomboon, Sukanda [1 ]
Pojprapai, Soodkhet [1 ]
机构
[1] Suranaree Univ Technol, Inst Engn, Sch Ceram Engn, Nakhon Ratchasima 30000, Thailand
[2] Suranaree Univ Technol, Inst Med, Nakhon Ratchasima 30000, Thailand
[3] Suranaree Univ Technol, Synchrotron Light Res Inst, Publ Org, 111 Univ Ave, Nakhon Ratchasima 30000, Thailand
[4] Univ Petr & Energy Studies, Ctr Interdisciplinary Res & Innovat CIDRI, Dehra Dun 248007, India
[5] Univ Petr & Energy Studies, Dept Phys, Dehra Dun 248007, India
关键词
QCM; PSA; Surface modification; Gold nanospike structures; Pulse current electrodeposition; Duty cycle; CANCER BIOMARKERS; QCM SENSOR;
D O I
10.1016/j.surfin.2024.103877
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Prostate-specific antigen (PSA) screening is vital for the early detection and assessment of prostate cancer treatment efficacy. Integrating nanotechnology into biosensor development allows for targeted biomarker detection. In this study, we present the fabrication of gold nanospikes (AuNS) structures on a quartz crystal microbalance (QCM) using the pulse current electrodeposition (PCD) technique. By varying the duty cycles of PCD, we achieved the desired nanostructure. The characteristics of the AuNS-modified QCM electrode were thoroughly investigated using various micro-structural characterization techniques such as x-ray diffraction (XRD), field emission scanning electron microscope (FESEM), atomic force microscope (AFM), X-ray photoelectron spectroscopy (XPS) and cyclic voltammetry (CV). Prior to biomolecule immobilization, each chemical treatment was verified through contact angle and FT -IR analyses. The performance of the developed QCM biosensor was evaluated using PSA at various concentrations. The results revealed that the frequency variation of the QCM biosensor was directly proportional to the PSA concentration. Notably, the AuNS-modified QCM biosensor exhibited the highest frequency shift at a 20 % duty cycle, demonstrating a linear detection range of 0.1-100 ng mL-1 and a limit of detection (LOD) of 24 pg mL-1. The developed QCM biosensor significantly enhances detection efficiency by increasing the number of binding sites for biomolecules through an enlarged surface area. The demonstrated sensitivity of the AuNS-modified QCM biosensor indicates its potential to address the increasing demand for early diagnosis and screening in healthcare systems. This innovative biosensor technology holds promise for improving prostate cancer detection and has broader implications for the development of highly sensitive biosensors for various biomarkers.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Effect of Surface Modified Quartz Crystal Microbalance (QCM) on Detection Sensitivity for Prostate Specific Antigen (PSA)
    Sonklin, Thita
    Munthala, Dhananjaya
    Suksaweang, Sanong
    Janphuang, Pattanaphong
    Pojprapai, Soodkhet
    INTEGRATED FERROELECTRICS, 2022, 222 (01) : 93 - 101
  • [2] Quartz crystal microbalance biosensor for the detection of procalcitonin
    Pohanka, Miroslav
    TALANTA, 2023, 257
  • [3] Quartz Crystal Microbalance Biosensor for Ergotamine Detection
    Pohanka, Miroslav
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (05): : 4179 - 4187
  • [4] Detection of Salmonella Typhimurium with Gold Nanoparticles Using Quartz Crystal Microbalance Biosensor
    Min, Hyun Jung
    Mina, Hansel A.
    Deering, Amanda J.
    Robinson, J. Paul
    Bae, Euiwon
    SENSORS, 2022, 22 (22)
  • [5] Detection of Gliadin in Foods Using a Quartz Crystal Microbalance Biosensor That Incorporates Gold Nanoparticles
    Chu, Pei-Tzu
    Lin, Chih-Sheng
    Chen, Wei-Jung
    Chen, Chih-Feng
    Wen, Hsiao-Wei
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (26) : 6483 - 6492
  • [6] A quartz crystal microbalance biosensor for the detection of total IgE
    Fahrullin, R.
    Fassakhov, R.
    Sukmanskaya, E.
    Konovalova, O.
    ALLERGY, 2007, 62 : 146 - 146
  • [7] Development of Portable Quartz Crystal Microbalance for Biosensor Applications
    Liang, Jinxing
    Zhang, Jing
    Wang, Peng
    Liu, Changchuan
    Qiu, Shi
    Ueda, Toshitsugu
    SENSORS AND MATERIALS, 2016, 28 (03) : 201 - 207
  • [8] Quartz crystal microbalance (QCM) affinity biosensor for genetically modified organisms (GMOs) detection
    Mannelli, I
    Minunni, M
    Tombelli, S
    Mascini, M
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3): : 129 - 140
  • [9] Detection of HIV-1 antigen by quartz crystal microbalance using gold nanoparticles
    Tan Nhiem Ly
    Park, Sangkwon
    Park, Sang Joon
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 237 : 452 - 458
  • [10] Quartz crystal microbalance biosensor for rapid detection of aerosolized microorganisms
    Farka, Zdenek
    Kovar, David
    Skladal, Petr
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XVI, 2015, 9455