Anatomical Structures to Be Concerned With During Peripherally Inserted Central Catheter Procedures

被引:0
|
作者
Kim, Dasom [1 ]
Park, Jin Woo [1 ]
Cho, Sung Bum [2 ]
Rhyu, Im Joo [1 ,3 ,4 ]
机构
[1] Korea Univ, Coll Med, Dept Anat, Seoul, South Korea
[2] Korea Univ, Coll Med, Dept Diagnost Radiol, Seoul, South Korea
[3] Korea Univ, Coll Med, Pract Anat Res Inst, Seoul, South Korea
[4] Korea Univ, Coll Med, Pract Anat Res Inst, Dept Anat, 73 Goryeodae Ro, Seoul 02841, South Korea
关键词
Central Venous Catheters; Catheterization; Peripherally Inserted Central Line (PICC); Basilic Vein; Ulnar Nerve; Brachial Artery; CENTRAL VENOUS CATHETERS; BURN PATIENTS; TIP POSITION; COMPLICATIONS; PLACEMENT; PICC; PREVENTION; NUTRITION; ACCESS; SAFETY;
D O I
10.3346/jkms.2023.38.e329
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The central line has been frequently used for drug and nutrition supply and regular blood sampling of patients with chronic diseases. However, this procedure is performed in a highly sensitive area and has several potential complications. Therefore, peripherally inserted central catheters (PICC), which have various advantages, are being extensively used. Although the number of PICC procedures is increasing, the anatomy for safe procedures has not yet been properly established. Therefore, we studied basic anatomical information for safe procedures.Methods: We used 20 fixed cadavers (40 arms) donated to the Korea University College of Medicine. The mean age was 76.75 years (range, 48-94 years). After dissection of each arm, the distribution pattern of the basilic vein and close structures was recorded, and some important parameters based on bony landmarks were measured. In addition, the number of vein branches (axillary region) and basilic vein diameter were also checked.Results: The mean length from the insertion site to the right atrium was 38.39 +/- 2.63 cm (left) and 34.66 +/- 3.60 cm (right), and the basilic vein diameter was 4.93 +/- 1.18 mm (left) and 4.08 +/- 1.49 mm (right). The data showed significant differences between the left and right arms (P < 0.05). The mean distance from the basilic vein to brachial artery was 8.29 +/- 2.78 mm in men and 7.81 +/- 2.78 mm in women, while the distance to the ulnar nerve was 5.41 +/- 1.67 mm in men and 5.52 +/- 2.06 mm in women.Conclusion: According to these results, the right arm has a shorter distance from the insertion site to the right atrium, and the left arm has a wider vein diameter, which is advantageous for the procedure. In addition, the ulnar nerve and brachial artery were located close to or behind the insertion site. Therefore, special attention is required during the procedure to avoid damaging these important structures.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Inadvertent Arterial Peripherally Inserted Central Catheter Insertion With Corresponding Electrocardiographic Tracings: A Case Report
    DiLoreto, Emily
    Bahl, Amit
    JOURNAL OF INFUSION NURSING, 2022, 45 (01) : 37 - 40
  • [42] Accuracy and Safety Study of Intracavitary Electrocardiographic Guidance for Peripherally Inserted Central Catheter Placement in Neonates
    Ling, Qiying
    Chen, Hong
    Tang, Min
    Qu, Yi
    Tang, Binzhi
    JOURNAL OF PERINATAL & NEONATAL NURSING, 2019, 33 (01) : 89 - 95
  • [43] Peripherally Inserted Central Catheter Complications in Neonates With Upper Versus Lower Extremity Insertion Sites
    Wrightson, Della Daugherty
    ADVANCES IN NEONATAL CARE, 2013, 13 (03) : 198 - 204
  • [44] Peripherally Inserted Central Line Catheter Infections in Burn Patients
    Barsun, Alura
    Sen, Soman
    Palmieri, Tina L.
    Greenhalgh, David G.
    JOURNAL OF BURN CARE & RESEARCH, 2014, 35 (06): : 514 - 517
  • [45] Perforations associated with peripherally inserted central catheters in a neonatal population
    Sertic, Andrew J.
    Connolly, Bairbre L.
    Temple, Michael J.
    Parra, Dimitri A.
    Amaral, Joao G.
    Lee, Kyong-Soon
    PEDIATRIC RADIOLOGY, 2018, 48 (01) : 109 - 119
  • [46] Catheter-related bloodstream infection associated with multiple insertions of the peripherally inserted central catheter in patients with hematological disorders
    Hashimoto, Yoshinori
    Hosoda, Rina
    Omura, Hiromi
    Tanaka, Takayuki
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [47] The nurse in the prevention of peripherally inserted central catheter infection in neonates
    Russo, Natalia Contecote
    Lopes, Alexandre
    Prata de Oliveira, Rafaela Aparecida
    Mondelli, Alessandro Lia
    Correa, Ione
    VIGILANCIA SANITARIA EM DEBATE-SOCIEDADE CIENCIA & TECNOLOGIA, 2020, 8 (02): : 134 - 143
  • [48] Upper body peripherally inserted central catheter in pediatric single ventricle patients
    Kaipa, Santosh
    Mastropietro, Christopher W.
    Bhai, Hamza
    Lutfi, Riad
    Friedman, Matthew L.
    Yabrodi, Mouhammad
    WORLD JOURNAL OF CARDIOLOGY, 2020, 12 (10): : 484 - 491
  • [49] Risk factors associated with adverse events in neonates with peripherally inserted central catheter
    Padilla-Sanchez, C.
    Montejano-Lozoya, R.
    Benavent-Taengua, L.
    Monedero-Valero, A.
    Borras-Vano, M. J.
    Angel-Selfa, M. J.
    Riera-Torres, M. J.
    ENFERMERIA INTENSIVA, 2019, 30 (04): : 170 - 180
  • [50] Prospective Randomized Comparative Evaluation of Proximal Valve Polyurethane and Distal Valve Silicone Peripherally Inserted Central Catheters
    Ong, Cheng K.
    Venkatesh, Sudhakar K.
    Lau, Gabriel B.
    Wang, Shih C.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (08) : 1191 - 1196