In Vitro Permeability Study of Homotaurine Using a High-Performance Liquid Chromatography with Fluorescence Detection Pre-Column Derivatization Method

被引:2
|
作者
Ntorkou, Marianna [1 ]
Tsanaktsidou, Eleni [1 ]
Chachlioutaki, Konstantina [2 ]
Fatouros, Dimitrios G. [2 ]
Markopoulou, Catherine K. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Pharm, Lab Pharmaceut Anal, Thessaloniki 54124, Greece
[2] Aristotle Univ Thessaloniki, Dept Pharm, Lab Pharmaceut Technol, Thessaloniki 54124, Greece
来源
MOLECULES | 2023年 / 28卷 / 20期
关键词
homotaurine; derivatization; HPLC-FLD; CNS permeability study; ALZHEIMERS-DISEASE; AMINO-ACIDS; TAURINE; TRAMIPROSATE; PLASMA;
D O I
10.3390/molecules28207086
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Homotaurine (HOM) is considered a promising drug for the treatment of Alzheimer's and other neurodegenerative diseases. In the present work, a new high-performance liquid chromatography with fluorescence detection (HPLC-FLD) (lambda ex. = 340 nm and lambda em. = 455 nm) method was developed and validated for the study of substance permeability in the central nervous system (CNS). Analysis was performed on a RP-C18 column with a binary gradient elution system consisting of methanol-potassium phosphate buffer solution (pH = 7.0, 0.02 M) as mobile phase. Samples of homotaurine and histidine (internal standard) were initially derivatized with ortho-phthalaldehyde (OPA) (0.01 M), N-acetylcysteine (0.01 M) and borate buffer (pH = 10.5; 0.05 M). To ensure the stability and efficiency of the reaction, the presence of different nucleophilic reagents, namely (a) 2-mercaptoethanol (2-ME), (b) N-acetylcysteine (NAC), (c) tiopronin (Thiola), (d) 3-mercaptopropionic acid (3-MPA) and (e) captopril, was investigated. The method was validated (R-2 = 0.9999, intra-day repeatability %RSD < 3.22%, inter-day precision %RSD = 1.83%, limits of detection 5.75 ng/mL and limits of quantification 17.43 ng/mL, recovery of five different concentrations 99.75-101.58%) and successfully applied to investigate the in vitro permeability of homotaurine using Franz diffusion cells. The apparent permeability (P-app) of HOM was compared with that of memantine, which is considered a potential therapeutic drug for various CNSs. Our study demonstrates that homotaurine exhibits superior permeability through the simulated blood-brain barrier compared to memantine, offering promising insights for enhanced drug delivery strategies targeting neurological conditions.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Development and Validation of a High-Performance Liquid Chromatography Method for the Determination of Histamine in Fish Samples Using Fluorescence Detection with Pre-column Derivatization
    Ayoub Kounnoun
    Mohamed EL Maadoudi
    Francesco Cacciola
    Luigi Mondello
    Hajar Bougtaib
    Naoual Alahlah
    Nadia Amajoud
    Aicha EL Baaboua
    Adnane Louajri
    Chromatographia, 2020, 83 : 893 - 901
  • [2] Development and Validation of a High-Performance Liquid Chromatography Method for the Determination of Histamine in Fish Samples Using Fluorescence Detection with Pre-column Derivatization
    Kounnoun, Ayoub
    El Maadoud, Mohamed
    Cacciola, Francesco
    Mondello, Luigi
    Bougtaib, Hajar
    Alahlah, Naoual
    Amajoud, Nadia
    El Baaboua, Aicha
    Louajri, Adnane
    CHROMATOGRAPHIA, 2020, 83 (07) : 893 - 901
  • [3] Determination of autoinducer-2 in biological samples by high-performance liquid chromatography with fluorescence detection using pre-column derivatization
    Song, Xiang-Ning
    Qiu, Hai-Bin
    Xiao, Xiang
    Cheng, Yuan-Yuan
    Li, Wen-Wei
    Sheng, Guo-Ping
    Li, Xiao-Yan
    Yu, Han-Qing
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1361 : 162 - 168
  • [4] Analysis of peptides and amino acids by pre-column derivatization high performance liquid chromatography with fluorescence detection
    Liu, X
    Xu, GL
    Zhang, HS
    Cheng, JK
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1997, 18 (06): : 873 - 876
  • [5] A high-performance liquid chromatography method with pre-column derivatization for the simultaneous determination of reduced glutathione, carnosine and taurine
    Khalikova, Maria A.
    Satinsky, Dalibor
    Solich, Petr
    Zinchenko, Alexandr A.
    Zhilyakova, Elena T.
    Novikov, Oleg O.
    ANALYTICAL METHODS, 2014, 6 (05) : 1475 - 1481
  • [6] A novel and sensitive method for determining vitamin B3 and B7 by pre-column derivatization and high-performance liquid chromatography method with fluorescence detection
    Fan, Baolei
    You, Jinmao
    Suo, Yourui
    Qian, Chunqi
    PLOS ONE, 2018, 13 (06):
  • [7] High-performance liquid chromatographic determination of taurine in human plasma using pre-column extraction and derivatization
    McMahon, GP
    OKennedy, R
    Kelly, MT
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (8-10) : 1287 - 1294
  • [8] Quantification of cyclamate and cyclohexylamine in urine samples using high-performance liquid chromatography with trinitrobenzenesulfonic acid pre-column derivatization
    Casals, I
    Reixach, M
    Amat, J
    Fuentes, M
    SerraMajem, L
    JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) : 397 - 402
  • [9] Development of an automated on-line pre-column derivatization procedure for sensitive determination of histamine in food with high-performance liquid chromatography-fluorescence detection
    Peng, Jin-feng
    Fang, Ke-teng
    Me, Dong-hua
    Ding, Bin
    Yin, Ju-Yi
    Cui, Xiao-mei
    Zhang, Ying
    Liu, Jing-fu
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1209 (1-2) : 70 - 75
  • [10] Analysis of monosacchaaride compositions in polysaccharides by pre-column derivatization high performance liquid chromatography
    Ma, DY
    Chen, J
    Li, P
    Hu, ZY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (06) : 702 - 705