Comparison of Radiation Dose and Image Quality of Pediatric High-Resolution Chest CT Between Photon-Counting Detector CT and Energy-Integrated Detector CT: A Matched Study

被引:8
作者
Siegel, Marilyn J. [1 ]
Bugenhagen, Scott M. [1 ]
Sanchez, Adrian [1 ]
Kim, Stacy [1 ]
Abadia, Andres [1 ]
Ramirez-Giraldo, Juan C. [1 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, Sch Med, 510 S Kingshighway Blvd, St Louis, MO 63110 USA
关键词
CT; high-resolution CT; pediatrics; photon-counting CT; radiation dose; COMPUTED-TOMOGRAPHY; 100; KVP; REDUCTION; AGREEMENT; SELECTION;
D O I
10.2214/AJR.23.29077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BACKGROUND. Photon-counting detector (PCD) CT has been shown to reduce radiation dose and improve image quality in adult chest CT examinations; its potential impact in pediatric CT is not well documented. OBJECTIVE. The purpose of our study was to compare radiation dose, objective image quality, and subjective image quality of PCD CT and energy-integrating detector (EID) CT in children undergoing high-resolution CT (HRCT) of the chest. METHODS. This retrospective study included 27 children (median age, 3.9 years; 10 girls, 17 boys) who underwent PCD CT between March 1, 2022, and August 31, 2022, and 27 children (median age, 4.0 years; 13 girls, 14 boys) who underwent EID CT between August 1, 2021, and January 31, 2022; all examinations comprised clinically indicated chest HRCT. The patients in the two groups were matched by age and water-equivalent diameter. Radiation dose parameters were recorded. One observer placed ROIs to measure objective parameters (lung attenuation, image noise, and SNR). Two radiologists independently assessed subjective measures (overall image quality and motion artifacts) using 5-point Likert scales (1 = highest quality). Groups were compared. RESULTS. PCD CT, in comparison with EID CT, showed lower median CTDI vol (0.41 vs 0.71 mGy, p < .001), DLP (10.2 vs 13.7 mGy x cm, p = .008), size-specific dose estimate (0.82 vs 1.34 mGy, p < .001), and tube current-exposure time product (48.0 vs 202.0 mAs, p < .001). PCD CT and EID CT showed no significant difference in right upper lobe (RUL) lung attenuation (mean, -793 vs -750 HU; p = .09), right lower lobe (RLL) lung attenuation (mean, -745 vs -716 HU; p = .23), RUL image noise (mean, 55 vs 51 HU; p = .27), RLL image noise (mean, 59 vs 57 HU; p = .48), RUL SNR (mean, -14.9 vs -15.8; p = .89), or RLL SNR (mean, -13.1 vs -13.6; p = .79). PCD CT and EID CT showed no significant difference in median overall image quality for reader 1 (1.0 vs 1.0, p = .28) or reader 2 (1.0 vs 1.0, p = .17) or median motion artifacts for reader 1 (1.0 vs 1.0, p = .07) or reader 2 (1.0 vs 1.0, p = .22). CONCLUSION. PCD CT showed significantly reduced dose levels without a significant difference in objective or subjective image quality compared with EID CT.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 23 条
  • [1] High-Resolution Chest Computed Tomography Imaging of the Lungs Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography
    Bartlett, David J.
    Koo, Chi Wan
    Bartholmai, Brian J.
    Rajendran, Kishore
    Weaver, Jayse M.
    Halaweish, Ahmed E.
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    [J]. INVESTIGATIVE RADIOLOGY, 2019, 54 (03) : 129 - 137
  • [2] Single-energy pediatric chest computed tomography with spectral filtration at 100 kVp: effects on radiation parameters and image quality
    Bodelle, Boris
    Fischbach, Constanze
    Booz, Christian
    Yel, Ibrahim
    Frellesen, Claudia
    Kaup, Moritz
    Beeres, Martin
    Vogl, Thomas J.
    Scholtz, Jan-Erik
    [J]. PEDIATRIC RADIOLOGY, 2017, 47 (07) : 831 - 837
  • [3] Pediatric Applications of Photon-Counting Detector CT
    Cao, Joseph
    Bache, Steve
    Schwartz, Fides R.
    Frush, Donald
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (04) : 580 - 589
  • [4] Dose Reduction in Helical CT: Dynamically Adjustable z-Axis X-Ray Beam Collimation
    Christner, Jodie A.
    Zavaletta, Vanessa A.
    Eusemann, Christian D.
    Walz-Flannigan, Alisa I.
    McCollough, Cynthia H.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) : W49 - W55
  • [5] HIGH AGREEMENT BUT LOW KAPPA .2. RESOLVING THE PARADOXES
    CICCHETTI, DV
    FEINSTEIN, AR
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 1990, 43 (06) : 551 - 558
  • [6] Esquivel A, 2022, KOREAN J RADIOL, V23, P854
  • [7] Review of Technical Advancements and Clinical Applications of Photon-counting Computed Tomography in Imaging of the Thorax
    Farhadi, Faraz
    Rajagopal, Jayasai R.
    Nikpanah, Moozhan
    Sahbaee, Pooyan
    Malayeri, Ashkan A.
    Pritchard, William F.
    Samei, Ehsan
    Jones, Elizabeth C.
    Chen, Marcus Y.
    [J]. JOURNAL OF THORACIC IMAGING, 2021, 36 (02) : 84 - 94
  • [8] Dose Reduction and Image Quality in Photon-counting Detector High-resolution Computed Tomography of the Chest Routine Clinical Data
    Graafen, Dirk
    Emrich, Tilman
    Halfmann, Moritz C.
    Mildenberger, Peter
    Dueber, Christoph
    Yang, Yang
    Othman, Ahmed E.
    O' Doherty, Jim
    Mueller, Lukas
    Kloeckner, Roman
    [J]. JOURNAL OF THORACIC IMAGING, 2022, 37 (05) : 315 - 322
  • [9] Pilot study to determine whether reduced-dose photon-counting detector chest computed tomography can reliably display Brody II score imaging findings for children with cystic fibrosis at radiation doses that approximate radiographs
    Horst, Kelly K.
    Hull, Nathan C.
    Thacker, Paul G.
    Demirel, Nadir
    Yu, Lifeng
    McDonald, Jennifer S.
    Larson, Nicholas B.
    McCollough, Cynthia H.
    Fletcher, Joel G.
    [J]. PEDIATRIC RADIOLOGY, 2023, 53 (06) : 1049 - 1056
  • [10] Potential of Photon-Counting Detector CT for Radiation Dose Reduction for the Assessment of Interstitial Lung Disease in Patients With Systemic Sclerosis
    Jungblut, Lisa
    Euler, Andre
    von Spiczak, Jochen
    Sartoretti, Thomas
    Mergen, Victor
    Englmaier, Vanessa
    Landsmann, Anna
    Mihai, Carmen-Marina
    Distler, Oliver
    Alkadhi, Hatem
    Frauenfelder, Thomas
    Martini, Katharina
    [J]. INVESTIGATIVE RADIOLOGY, 2022, 57 (12) : 773 - 779