Endosteal strut using a hydroxyapatite/poly-l-lactide mesh tube with a proximal humeral locking plate for the treatment of proximal humeral fractures

被引:0
作者
Iwata, Hidetoshi [1 ]
Takada, Naoya [1 ]
Kuroyanagi, Gen [2 ]
Yamamoto, Norio [3 ]
Usami, Takuya [2 ]
Sekiya, Isato [1 ]
Murakami, Hideki [2 ]
机构
[1] Kainan Hosp Aichi Prefectural Welf Federat Agr Coo, Dept Orthoped Surg, Yatomi, Japan
[2] Nagoya City Univ, Dept Orthoped Surg, Grad Sch Med Sci, 1 Kawasumi, Mizuho ku, Nagoya, Aichi 4678601, Japan
[3] Miyamoto Orthoped Hosp, Dept Orthoped Surg, Okayama 7738236, Japan
关键词
Proximal humeral fractures; Open-reduction internal fixation; Osteosynthesis; Hydroxyapatite; poly-l-lactide mesh tube; Endosteal strut; FORGED COMPOSITES; AUGMENTATION; EPIDEMIOLOGY; REDUCTION; ALLOGRAFT; FIXATION; OUTCOMES; SUPPORT;
D O I
10.1007/s00590-023-03638-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeProximal humeral fractures cause large intramedullary bone defects after humeral-head reduction. Hydroxyapatite/poly-l-lactide (HA/PLLA) materials are widely used for various fractures. However, the efficacy of endosteal strut using a HA/PLLA mesh tube (ES-HA/PLLA) with a locking plate for treating proximal humeral fractures was not reported. The purpose of this study is to examine the efficacy of ES-HA/PLLA with a proximal humeral locking plate in proximal humeral fractures.MethodsSeventeen patients with proximal humeral fractures treated using ES-HA/PLLA with a locking plate from November 2017 to November 2021 were evaluated. The range of motion of the shoulder and postoperative complications were assessed at the final follow-up. Radiographs were evaluated to assess bone union and loss of reduction by measuring humeral-head height (HHH) and humeral neck-shaft angle (NSA).ResultsThe average flexion and external rotation of the shoulder at the final follow-up were 137 & DEG; (range, 90-180 & DEG;) and 39 & DEG; (range, - 10 to 60 & DEG;), respectively. All fractures were united. The average HHH and NSA just after the surgery and final follow-up were 12.5 mm and 11.6 mm and 129.9 & DEG; and 127.4 & DEG;, respectively. Two patients presented screw perforation of the humeral head. One patient underwent implant removal due to infection. Avascular necrosis of the humeral head was observed in one patient with arthritis mutilans.ConclusionsThe use of ES-HA/PLLA with a proximal humeral locking plate resulted in bone union in all patients and prevented postoperative loss of reduction. ES-HA/PLLA is one of the treatment options for proximal humeral fractures.
引用
收藏
页码:217 / 223
页数:7
相关论文
共 50 条
[21]   Prognostic factors for unstable proximal humeral fractures treated with locking-plate fixation [J].
Lee, Churl-Woo ;
Shin, Sang-Jin .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (01) :83-88
[22]   Functional Outcomes Following Locking Plate Fixation of Complex Proximal Humeral Fractures [J].
Ye, Tingjun ;
Wang, Lei ;
Zhuang, Chengyu ;
Wang, Yazi ;
Zhang, Weibin ;
Qiu, Shijing .
ORTHOPEDICS, 2013, 36 (06) :E715-E722
[23]   Importance of locking plate positioning in proximal humeral fractures as predicted by computer simulations [J].
Fletcher, James W. A. ;
Windolf, Markus ;
Richards, R. Geoff ;
Gueorguiev, Boyko ;
Buschbaum, Jan ;
Varga, Peter .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2019, 37 (04) :957-964
[24]   Comparison of variable and fixed angle proximal humeral locking plates for the treatment of displaced proximal humerus fractures [J].
Connelly, James W. ;
Covarrubias, Oscar ;
Toavs, Trevor L. ;
Meltzer, Jourdan H. ;
Molino, Janine ;
Tapscott, David ;
Green, Andrew ;
Paxton, E. Scott .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2025, 56 (08)
[25]   Fibular strut allograft influences reduction and outcomes after locking plate fixation of comminuted proximal humeral fractures in elderly patients: a retrospective study [J].
Cui, Xueliang ;
Chen, Hui ;
Ma, Binbin ;
Fan, Wenbin ;
Li, He .
BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
[26]   Meta-analysis of locking plate versus intramedullary nail for treatment of proximal humeral fractures [J].
Guoqi Wang ;
Zhi Mao ;
Lihai Zhang ;
Licheng Zhang ;
Yanpeng Zhao ;
Peng Yin ;
Ling Gao ;
Peifu Tang ;
Hongjun Kang .
Journal of Orthopaedic Surgery and Research, 10
[27]   Efficacy of fibular allograft and locking plate in the treatment of proximal humeral fracture [J].
Li, Dezhi ;
Chen, Shengwen ;
Mao, Jun ;
Deng, Ting .
ASIAN JOURNAL OF SURGERY, 2023, 46 (03) :1372-1373
[28]   Locking plate versus nonsurgical treatment for proximal humeral fractures: better midterm outcome with nonsurgical treatment [J].
Sanders, Rick J. ;
Thissen, Luc G. ;
Teepen, Jop C. ;
van Kampen, Albert ;
Jaarsma, Ruurd L. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (07) :1118-1124
[29]   Comparative study between locking plates versus proximal humeral nail for the treatment of 2-part proximal humeral fractures [J].
Domingo Trepat, Anna ;
Popescu, Dragos ;
Angel Fernandez-Valencia, Jenaro ;
Cune, Jordi ;
Rios, Moises ;
Prat, Salvi .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2012, 22 (05) :373-379
[30]   Comparison of surgical outcomes of osteosynthesis using anatomical locking plates with proximal screws and smooth pegs for proximal humeral fractures [J].
Furuhata, Ryogo ;
Tanji, Atsushi ;
Kamata, Yusaku ;
Matsumura, Noboru .
BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)