Alternative Forward Models for Imaging Thick Specimens in Transmission Electron Microscopy

被引:0
作者
Koeck, Philip Johannes Barrett [1 ]
机构
[1] Royal Inst Technol, Sch Engn Sci Chem Biotechnol & Hlth, Halsovagen 11 C, S-14152 Huddinge, Sweden
关键词
defocus gradient; multislice; phase objects; TEM; 3DCtf; APPROXIMATIONS; PHASE;
D O I
10.1093/micmic/ozad038
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
I have investigated two different forward models for image formation in transmission electron microscopy of thick specimens, the 3DCtf model, which introduces a defocus gradient in the linear approximation, and the multislice model. An important result is that the 3DCtf model does not seem to be compatible with the multislice image formation model. A second very useful finding is that the exit wave in the multislice model has an imaginary part, which, in first-order approximation, is a pure projection of the specimen and is not affected by the defocus gradient. The defocus gradient only comes into play in real valued and higher-order imaginary terms. If the multislice model is closer to reality than the 3DCtf-model, then the best way to retrieve the specimen projection for thicker specimens should be a procedure for retrieving the exit wave's imaginary term, for example using images recorded at different defocus values.
引用
收藏
页码:1071 / 1076
页数:6
相关论文
共 12 条
  • [1] [Anonymous], 2006, Three-dimensional electron microscopy of macromolecular assemblies: visualization of biological molecules in their native state
  • [2] Cowley J. M., 1995, DIFFRACTION PHYS
  • [3] SimulaTEM: Multislice simulations for general objects
    Gomez-Rodriguez, A.
    Beltran-del-Rio, L. M.
    Herrera-Becerra, R.
    [J]. ULTRAMICROSCOPY, 2010, 110 (02) : 95 - 104
  • [4] Defocus-gradient corrected back-projection
    Jensen, GJ
    Kornberg, RD
    [J]. ULTRAMICROSCOPY, 2000, 84 (1-2) : 57 - 64
  • [5] Limitations of the linear and the projection approximations in three-dimensional transmission electron microscopy of fully hydrated proteins
    Koeck, P. J. B.
    Karshikoff, A.
    [J]. JOURNAL OF MICROSCOPY, 2015, 259 (03) : 197 - 209
  • [6] THE KHOROS SOFTWARE-DEVELOPMENT ENVIRONMENT FOR IMAGE-PROCESSING AND SIGNAL-PROCESSING
    KONSTANTINIDES, K
    RASURE, JR
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 1994, 3 (03) : 243 - 252
  • [7] VALIDITY OF WEAK-PHASE AND OTHER APPROXIMATIONS IN ANALYSIS OF ELECTRON-MICROSCOPE IMAGES
    MISELL, DL
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1976, 9 (13) : 1849 - 1866
  • [8] Comparison of phase contrast transmission electron microscopy with optimized scanning transmission annular dark field imaging for protein imaging
    Rez, P
    [J]. ULTRAMICROSCOPY, 2003, 96 (01) : 117 - 124
  • [9] Hydration-layer models for cryo-EM image simulation
    Shang, Zhiguo
    Sigworth, Fred J.
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2012, 180 (01) : 10 - 16
  • [10] Electron holography of biological samples
    Simon, P.
    Lichte, H.
    Formanek, P.
    Lehmann, M.
    Huhle, R.
    Carrillo-Cabrera, W.
    Harscher, A.
    Ehrlich, H.
    [J]. MICRON, 2008, 39 (03) : 229 - 256