The Effect of Wind Direction on the Cooling Capacity of Short Dry Natural Draft Cooling Towers Operating in Close Proximity

被引:1
作者
Khamooshi, Mehrdad [1 ]
Anderson, Timothy [2 ]
Nates, Roy
机构
[1] Monash Univ, Dept Mech & Aerosp Engn, Melbourne 3204, Australia
[2] Western Inst Technol Taranaki, Sch Engn Energy & Infrastructure, New Plymouth 4310, New Zealand
来源
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | 2024年 / 146卷 / 02期
关键词
cooling; heat transfer; thermal power; HEAT-TRANSFER CHARACTERISTICS; NUMERICAL-SIMULATION; PERFORMANCE IMPROVEMENT; CROSSWIND; FLOW; SYSTEM; ENHANCEMENT; RADIATORS;
D O I
10.1115/1.4063333
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The layout of multiple natural draft dry cooling towers could have a significant influence on the performance of the cooling system in concentrated solar power (CSP) plants; however, this has never been quantified. Hence, this work used computational fluid dynamics (CFD) modeling to analyze the cooling capacity of two short natural draft dry cooling towers (NDDCTs) on a common site for a range of tower spacings, wind-speeds, and wind incidence angles. The results show that the cooling performance of the towers is a strong function of tower spacing and their orientation with respect to the wind direction. It was found that when the wind came at a 90-deg wind incidence angle (i.e., normal to a line drawn between the two towers), their cooling capacity was improved at tower spacings of less than 1.8 tower diameters (1.8D), though for the other tower spacings, there was no interaction between the towers. However, with the wind at 45 deg to the towers, the flow around the towers resulted in a decrease in their cooling capacity at tower spacings of 1.8D and 2.6D. Most interestingly, it was found that orienting the towers in line with the prevailing wind direction delivered improvements in the cooling capacity of up to 30%. This is due to the windward tower acting as a passive windbreak. Hence, as CSP plant capacity is increased, and additional cooling towers are required, these should be placed close to any existing tower and oriented along the line of the prevailing winds.
引用
收藏
页数:19
相关论文
共 29 条
[1]   The performance of natural draft dry cooling towers under crosswind: CFD study [J].
Al-Waked, R ;
Behnia, M .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (02) :147-161
[2]   Performance improvement of natural draft dry cooling system by interior and exterior windbreaker configurations [J].
Chen, Lei ;
Yang, Lijun ;
Du, Xiaoze ;
Yang, Yongping .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 96 :42-63
[3]   Heat rejection enhancement in natural draft cooling tower using radiator-type windbreakers [J].
Goodarzi, M. ;
Keimanesh, R. .
ENERGY CONVERSION AND MANAGEMENT, 2013, 71 :120-125
[4]   Theoretical Prediction With Numerical and Experimental Verification to Predict Crosswind Effects on the Performance of Cooling Towers [J].
Hooman, Kamel .
HEAT TRANSFER ENGINEERING, 2015, 36 (05) :480-487
[5]  
Irtaza H., 2011, Int J Eng Sci Technol, V3, P116, DOI [10.4314/ijest.v3i6.10, DOI 10.4314/IJEST.V3I6.10]
[6]  
Khamooshi M., 2019, The Effect of Wind on Multiple, Short, Natural-Draft Dry Cooling Towers
[7]   Measurements of crosswind influence on a natural draft dry cooling tower for a solar thermal power plant [J].
Li, Xiaoxiao ;
Gurgenci, Hal ;
Guan, Zhiqiang ;
Wang, Xurong ;
Duniam, Sam .
APPLIED ENERGY, 2017, 206 :1169-1183
[8]   Full scale experimental study of a small natural draft dry cooling tower for concentrating solar thermal power plant [J].
Li, Xiaoxiao ;
Duniam, Sam ;
Gurgenci, Hal ;
Guan, Zhiqiang ;
Veeraragavan, Anand .
APPLIED ENERGY, 2017, 193 :15-27
[9]   Performance enhancement for the natural draft dry cooling tower under crosswind condition by optimizing the water distribution [J].
Li, Xiaoxiao ;
Xia, Lin ;
Gurgenci, Hal ;
Guan, Zhiqiang .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 107 :271-280
[10]   Simulation of the UQ Gatton natural draft dry cooling tower [J].
Li, Xiaoxiao ;
Guan, Zhiqiang ;
Gurgenci, Hal ;
Lu, Yuanshen ;
He, Suoying .
APPLIED THERMAL ENGINEERING, 2016, 105 :1013-1020