A Novel Method for Evaluating Early Tumor Response Based on Daily CBCT Images for Lung SBRT

被引:0
|
作者
Luo, Wei [1 ]
Xiu, Zijian [1 ]
Wang, Xiaoqin [2 ]
Mcgarry, Ronald [1 ]
Allen, Joshua [3 ]
机构
[1] Univ Kentucky, Dept Radiat Med, 800 Rose St, Lexington, KY 40536 USA
[2] Univ Kentucky, Dept Radiol, 800 Rose St, Lexington, KY 40536 USA
[3] AdventHlth, 2501 N Orange Ave, Orlando, FL 32804 USA
关键词
tumor response assessment; stereotactic radiation therapy (SBRT); cone-beam computerized tomography (CBCT); tumor area; tumor linear attenuation coefficient (mu); tumor contrast-to-noise ratio (CNR); RADIATION-THERAPY; CANCER; RADIOTHERAPY; REGRESSION;
D O I
10.3390/cancers16010020
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: We aimed to develop a new tumor response assessment method for lung SBRT. Methods: In total, 132 lung cancer patients with 134 tumors who received SBRT treatment with daily CBCT were included in this study. The information about tumor size (area), contrast (contrast-to-noise ratio (CNR)), and density/attenuation (mu) was derived from the CBCT images for the first and the last fractions. The ratios of tumor area, CNR, and mu (R-A, R-CNR, R-mu) between the last and first fractions were calculated for comparison. The product of the three rations was defined as a new parameter (R) for assessment. Tumor response was independently assessed by a radiologist based on a comprehensive analysis of the CBCT images. Results: R ranged from 0.27 to 1.67 with a mean value of 0.95. Based on the radiologic assessment results, a receiver operation characteristic (ROC) curve with the area under the curve (AUC) of 95% was obtained and the optimal cutoff value (R-C) was determined as 1.1. The results based on R-C achieved a 94% accuracy, 94% specificity, and 90% sensitivity. Conclusion: The results show that R was correlated with early tumor response to lung SBRT and that using R for evaluating tumor response to SBRT would be viable and efficient.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Gated CBCT Imaging for Positioning Moving Lung Tumor in Lung SBRT Treatment
    Li, X.
    Li, T.
    Zhang, Y.
    Burton, S.
    Karlovits, B.
    Clump, D.
    Heron, D.
    Huq, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 199 - 199
  • [2] Tumor Volume Change With Stereotactic Body Radiotherapy (SBRT) for Early-stage Lung Cancer Evaluating the Potential for Adaptive SBRT
    Bhatt, Aashish D.
    El-Ghamry, Moataz N.
    Dunlap, Neal E.
    Bhatt, Geetika
    Harkenrider, Matthew M.
    Schuler, John C.
    Zacarias, Albert
    Civelek, Ali Cahid
    Pan, Jianmin
    Rai, Shesh N.
    Woo, Shiao Y.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2015, 38 (01): : 41 - 46
  • [3] Adaptive Mathematical Model of Tumor Response to Radiotherapy Based on CBCT Data
    Belfatto, A.
    Riboldi, M.
    Ciardo, D.
    Cecconi, A.
    Lazzari, R.
    Jereczek-Fossa, B. A.
    Orecchia, R.
    Baroni, G.
    Cerveri, P.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (03) : 802 - 809
  • [4] Lung Tumor Delineation Based on Novel Tumor-Background Likelihood Models in PET-CT Images
    Wang, Xiuying
    Ballangan, Cherry
    Cui, Hui
    Fulham, Michael
    Eberl, Stefan
    Yin, Yong
    Feng, Dagan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (01) : 218 - 224
  • [5] Automated framework for estimation of lung tumor locations in kV-CBCT images for tumor-based patient positioning in stereotactic lung body radiotherapy
    Yoshidome, Satoshi
    Arimura, Hidetaka
    Terashima, Kotaro
    Hirakawa, Masakazu
    Hirose, Taka-aki
    Fukunaga, Junichi
    Nakamura, Yasuhiko
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [6] The Value of CBCT-based Tumor Density and Volume Variations in Prediction of Early Response to Chemoradiation Therapy in Advanced NSCLC
    Wen, Qiang
    Zhu, Jian
    Meng, Xue
    Ma, Changsheng
    Bai, Tong
    Sun, Xindong
    Yu, Jinming
    SCIENTIFIC REPORTS, 2017, 7
  • [7] First clinical retrospective investigation of limited projection CBCT for lung tumor localization in patients receiving SBRT treatment
    Zhang, Yawei
    Yin, Fang-Fang
    Ren, Lei
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (10) : 1 - 8
  • [8] Evaluation of Accuracy for Target Margin Size Obtained From CBCT On Lung SBRT Based On Film Dosimetry
    Lee, S.
    Park, J.
    Park, S.
    Lee, M.
    Kim, M.
    Suh, T.
    MEDICAL PHYSICS, 2014, 41 (06) : 259 - 259
  • [9] Mitigation of motion artifacts in CBCT of lung tumors based on tracked tumor motion during CBCT acquisition
    Lewis, John H.
    Li, Ruijiang
    Jia, Xun
    Watkins, W. Tyler
    Lou, Yifei
    Song, William Y.
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (17) : 5485 - 5502
  • [10] 4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm
    Li, Yi
    Ma, Jing-lu
    Chen, Xin
    Tang, Feng-wen
    Zhang, Xiao-zhi
    RADIATION ONCOLOGY, 2016, 11