Piezoelectric Wafer Active Sensor Transducers for Acoustic Emission Applications

被引:4
作者
Griffin, Connor [1 ]
Giurgiutiu, Victor [1 ]
机构
[1] Univ South Carolina, Dept Mech Engn, Columbia, SC 29208 USA
关键词
piezoelectric wafer active sensors; structural health monitoring;
D O I
10.3390/s23167103
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Piezoelectric materials are defined by their ability to display a charge across their surface in response to mechanical strain, making them great for use in sensing applications. Such applications include pressure sensors, medical devices, energy harvesting and structural health monitoring (SHM). SHM describes the process of using a systematic approach to identify damage in engineering infrastructure. A method of SHM that uses piezoelectric wafers connected directly to the structure has become increasingly popular. An investigation of a novel pitch-catch method of determining instrumentation quality of piezoelectric wafer active sensors (PWASs) used in SHM was conducted as well as an investigation into the effects of defects in piezoelectric sensors and sensor bonding on the sensor response. This pitch-catch method was able to verify defect-less instrumentation quality of pristinely bonded PWASs. Additionally, the pitch-catch method was compared with the electromechanical impedance method in determining defects in piezoelectric sensor instrumentation. Using the pitch-catch method, it was found that defective instrumentation resulted in decreasing amplitude of received and transmitted signals as well as changes in the frequency spectrums of the signals, such as the elimination of high frequency peaks in those with defects in the bonding layer and an increased amplitude of around 600 kHz for a broken PWAS. The electromechanical impedance method concluded that bonding layer defects increase the primary frequency peak's amplitude and cause a downward frequency shift in both the primary and secondary frequency peaks in the impedance spectrum, while a broken sensor has the primary peak amplitude reduced while shifting upward and nearly eliminating the secondary peak.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] A Review of Acoustic Impedance Matching Techniques for Piezoelectric Sensors and Transducers
    Rathod, Vivek T.
    SENSORS, 2020, 20 (14) : 1 - 65
  • [22] Corrosion damage detection with piezoelectric wafer active sensors
    Thomas, D
    Welter, J
    Giurgiutiu, V
    HEALTH MONITORING AND SMART NONDESTRUCTIVE EVALUATION OF STRUCTURAL AND BIOLOGICAL SYSTEM III, 2004, 5394 : 11 - 22
  • [23] Non-axisymmetric Lamb wave excitation by piezoelectric wafer active sensors
    Moll, Jochen
    Golub, Mikhail V.
    Glushkov, Evgeny
    Glushkova, Natalia
    Fritzen, Claus-Peter
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 174 : 173 - 180
  • [24] An initial investigation of the large strain and fatigue loading behavior of piezoelectric wafer active sensors
    Doane, J
    Giurgiutiu, V
    Smart Structures and Materials 2005: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace, Pts 1 and 2, 2005, 5765 : 1148 - 1159
  • [25] Effect of structural damping on the tuning between piezoelectric wafer active sensors and Lamb waves
    Mei, Hanfei
    Giurgiutiu, Victor
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2018, 29 (10) : 2177 - 2191
  • [26] Simulation of the Lamb wave interaction between piezoelectric wafer active sensors and host structure
    Bottai, G
    Giurgiutiu, V
    Smart Structures and Materials 2005: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace, Pts 1 and 2, 2005, 5765 : 259 - 270
  • [27] Adhesive disbond detection using piezoelectric wafer active sensors
    Roth, William
    Giurgiutiu, Victor
    STRUCTURAL HEALTH MONITORING AND INSPECTION OF ADVANCED MATERIALS, AEROSPACE, AND CIVIL INFRASTRUCTURE 2015, 2015, 9437
  • [28] Development of specifications for an integrated piezoelectric wafer active sensors system
    Jenkins, C
    Giurgiutiu, V
    Lin, B
    Liu, WP
    Smart Structures and Materials 2005: Smart Structures and Integrated Systems, 2005, 5764 : 509 - 521
  • [29] Deployment of piezoelectric transducers for diverse technical applications: A comprehensive review
    Shee, Chirantan
    Banerjee, Swagata
    Alagirusamy, R.
    Ali, S. Wazed
    RESULTS IN ENGINEERING, 2025, 25
  • [30] Development of a low-power wireless acoustic emission sensor node for aerospace applications
    Grigg, Stephen
    Pullin, Rhys
    Pearson, Matthew
    Jenman, David
    Cooper, Robert
    Parkins, Andrew
    Featherston, Carol Ann
    STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (04)