Investigation of elevator-aided evacuation strategies for older people in high-rise elderly housing

被引:5
作者
Fang, Hongqiang [1 ]
Wang, Qiao [2 ]
Qiu, Hongpeng [3 ]
Yang, Chendi [1 ]
Lo, S. M. [1 ]
机构
[1] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Peoples R China
[2] Southwest Jiaotong Univ, Sch Transportat & Logist, Chengdu 610031, Peoples R China
[3] Southwest Jiaotong Univ, Dept Fire Safety Engn, Chengdu 610031, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2023年 / 64卷
关键词
High-rise buildings; Elevator-aided evacuation; Older people; Evacuation simulation; Strategic analysis; SHAFT PRESSURIZATION; TALL BUILDINGS; SMOKE CONTROL; FIRE; BEHAVIOR; PERFORMANCE; OCCUPANTS; TIME;
D O I
10.1016/j.jobe.2022.105664
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Staircase evacuation is the major means of fire evacuation for current high-rise residential buildings. However, its feasibility may be questioned as the increasing aging population and many recent constructions of elderly community estates comprising high-rise apartment buildings. The weakness in physical strength and mobility impairment of older people may impede the successful implementation of staircase evacuation. Therefore, it is reasonable to consider facilitating older people's evacuation with elevators, shorted as elevator-aided evacuation (EAE). In order to find the most appropriate EAE strategy for high-rise elderly housing evacuation, three possbile strategy modes for EAE are proposed: horizontally rationed EAE (S1), vertically rationed EAE (S2), and refuge floor gathered EAE (S3). Using evacuation simulation to examine evacuation efficiencies of these proposed strategy modes varying in different evacuation scenarios, we find that S2 is appropriate for middle high-rise building (12 & 24 stories) evacuation; S3 is suitable for ultra high-rise building (36 & 48 stories) evacuation with a low occupants' density per floor; S1 is the most preferable for evacuation of ultra high-rise buildings (36 & 48 stories) with a high occupants' density per floor. More importantly, the ratio of occupants assigned to use elevators and stairs for evacuation needs to be regulated according to the occupancy information. Thus, a smart elevator-aided building fire evacuation scheme is suggested, which aims to determine the optimal EAE strategy according to the real-time on-site situation.
引用
收藏
页数:19
相关论文
共 67 条
  • [1] Experimental Investigation of the Effect of Fire Protection Lobby on Stair Pressurization System in a High-Rise Building
    Acikyol, Busra Hepguzel
    Kilic, Abdurrahman
    Balik, Gokhan
    [J]. FIRE TECHNOLOGY, 2017, 53 (01) : 135 - 151
  • [2] Agarwal Y., 2010, Proceedings of the ACM Workshop On Embedded Sensing Systems For Energy-Efficiency In Buildings (BuildSys '10), P1, DOI [10.1145/1878431.1878433, DOI 10.1145/1878431.1878433]
  • [3] Tall Buildings and Elevators: A Review of Recent Technological Advances
    Al-Kodmany, Kheir
    [J]. BUILDINGS, 2015, 5 (03): : 1070 - 1104
  • [4] High-rise building fire safety using mechanical ventilation and stairwell pressurization: A review
    Alianto, Beline
    Nasruddin, N.
    Nugroho, Yulianto Sulistyo
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 50
  • [5] Evacuation experiments in a virtual reality high-rise building: exit choice and waiting time for evacuation elevators
    Andree, Kristin
    Nilsson, Daniel
    Eriksson, Joakim
    [J]. FIRE AND MATERIALS, 2016, 40 (04) : 554 - 567
  • [6] [Anonymous], 2019, WORLD POP AG 2019
  • [7] [Anonymous], 2012, International Building Code
  • [8] Antell James H., 2012, 9 WORLD C
  • [10] Toward the characterization of building occupancies for Fire safety engineering: Capabilities of disabled people moving horizontally and on an incline
    Boyce, KE
    Shields, TJ
    Silcock, GWH
    [J]. FIRE TECHNOLOGY, 1999, 35 (01) : 51 - 67