Multiplexed detection of biomarkers using a microfluidic chip integrated with mass-producible micropillar array electrodes

被引:12
作者
Chen, Chaozhan [1 ,2 ,3 ]
Ran, Bin [1 ,2 ,3 ]
Liu, Bo [1 ,2 ,3 ]
Liu, Xiaoxuan [1 ,3 ]
Zhang, Ziteng [4 ]
Li, Yan [4 ]
Li, Hongchun [4 ]
Lan, Minbo [5 ]
Zhu, Yonggang [1 ,2 ,3 ]
机构
[1] Harbin Inst Technol, Sch Sci, Shenzhen 518055, Peoples R China
[2] Harbin Inst Technol, Sch Mech Engn & Automat, Shenzhen 518055, Peoples R China
[3] Harbin Inst Technol, Ctr Microflows & Nanoflows, Shenzhen 518055, Peoples R China
[4] Shenzhen Third Peoples Hosp, Shenzhen 518112, Peoples R China
[5] East China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
关键词
Electrochemical detection; Mass-producible micropillar array electrode; Biomarker detection; High sensitivity; ELECTROCHEMICAL DETECTION; CARBON NANOTUBE; GRAPHENE; GLUCOSE; SENSOR; SARCOSINE; FABRICATION; BIOSENSOR; H2O2; PD;
D O I
10.1016/j.aca.2023.341450
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantifying multiple biomarkers with high sensitivity in tiny biological samples is essential to meet the growing demand for point-of-care testing. This paper reports the development of a novel microfluidic device integrated with mass-producible micropillar array electrodes (& mu;AEs) for multiple biomarker detections. The & mu;AE are massfabricated by soft lithography and hot embossing technique. Pt-Pd bimetallic nanoclusters (BNC) are modified on the surface of & mu;AEs by constant potential (CP)/multi-potential step (MPS) electrodeposition strategies to improve the electroanalytical performance. The experimental result displays that Pt-Pd BNC/& mu;AEs have good sensitivity enhancement compared with bare planar electrodes and bare & mu;AEs, the enhancement being 56.5 and 9.5 times respectively, from the results of the H2O2 detection. Furthermore, glucose, uric acid and sarcosine were used as model biomarkers to show the biosensing capability with high sensitivity. The linear range and LOD of the glucose, uric acid and sarcosine detection are 0.1 mM-12 mM, 10 & mu;M-800 & mu;M and 2.5 & mu;M-100 & mu;M, 58.5, 3.4 and 0.4 & mu;M, respectively. In particular, biosensing chips show wide linear ranges covering required detection ranges of glucose, uric acid and sarcosine in human serum, indicating the developed device has great potential in selfhealth management and clinical requirements.
引用
收藏
页数:11
相关论文
共 57 条
[1]   Non-enzymatic electrochemical detection of cholesterol using β-cyclodextrin functionalized graphene [J].
Agnihotri, Nidhi ;
Chowdhury, Ankan Dutta ;
De, Amitabha .
BIOSENSORS & BIOELECTRONICS, 2015, 63 :212-217
[2]  
Chen C., 2022, BIOSENSORS, V12
[3]   Development of a novel microfluidic biosensing platform integrating micropillar array electrode and acoustic microstreaming techniques [J].
Chen, Chaozhan ;
Ran, Bin ;
Liu, Bo ;
Liu, Xiaoxuan ;
Liu, Ya ;
Lan, Minbo ;
Manasseh, Richard ;
Zhu, Yonggang .
BIOSENSORS & BIOELECTRONICS, 2023, 223
[4]   Development of micropillar array electrodes for highly sensitive detection of biomarkers [J].
Chen, Chaozhan ;
Ran, Bin ;
Wang, Zhenxing ;
Zhao, Hongli ;
Lan, Minbo ;
Chen, Huaying ;
Zhu, Yonggang .
RSC ADVANCES, 2020, 10 (67) :41110-41119
[5]   Multiplexed detection of cancer biomarkers using a microfluidic platform integrating single bead trapping and acoustic mixing techniques [J].
Chen, Huaying ;
Chen, Chang ;
Bai, Siwei ;
Gao, Yuan ;
Metcalfe, Guy ;
Cheng, Wenlong ;
Zhu, Yonggang .
NANOSCALE, 2018, 10 (43) :20196-20206
[6]   PMMA Micro-Pillar Forming in Micro Channel by Hot Embossing [J].
Chen, X. ;
Zhang, Z. ;
Gao, Q. .
INTERNATIONAL POLYMER PROCESSING, 2016, 31 (03) :364-368
[7]   Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers [J].
Chikkaveeraiah, Bhaskara V. ;
Bhirde, Ashwinkumar A. ;
Morgan, Nicole Y. ;
Eden, Henry S. ;
Chen, Xiaoyuan .
ACS NANO, 2012, 6 (08) :6546-6561
[8]   Simultaneous detection of glucose, uric acid and cholesterol using flexible microneedle electrode array-based biosensor and multi-channel portable electrochemical analyzer [J].
Gao, Jie ;
Huang, Wenzheng ;
Chen, Zhipeng ;
Yi, Changqing ;
Jiang, Lelun .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 287 :102-110
[9]   Drivers of biodiagnostic development [J].
Giljohann, David A. ;
Mirkin, Chad A. .
NATURE, 2009, 462 (7272) :461-464
[10]   Simultaneous monitoring of glucose and uric acid on a single test strip with dual channels [J].
Guo, Jinhong ;
Ma, Xing .
BIOSENSORS & BIOELECTRONICS, 2017, 94 :415-419