Loaded 5 Sit-to-Stand Test to Determine the Force-Velocity Relationship in Older Adults: A Validation Study

被引:4
作者
Bochicchio, Gianluca [1 ]
Ferrari, Luca [1 ,2 ]
Bottari, Alberto [1 ]
Lucertini, Francesco [2 ]
Cavedon, Valentina [1 ]
Milanese, Chiara [1 ]
Pogliaghi, Silvia [1 ,3 ]
机构
[1] Univ Verona, Dept Neurosci Biomed & Movement Sci, I-37131 Verona, Italy
[2] Univ Urbino, Dept Biomol Sci, I-61029 Urbino, Italy
[3] Univ Western Ontario, Res Associate Canadian Ctr Act & Ageing, London, ON N6A 3K7, Canada
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 13期
关键词
force-velocity; sit-to-stand; aging; strength test; field test; validation; clinical evaluation; muscle power; STRENGTH; PERFORMANCE; POWER;
D O I
10.3390/app13137837
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Force-velocity profiling (F-v) evaluates muscle function through the identification of maximum force (F0), velocity (V0), power (Pmax) and optimal velocity (Vopt). The purpose of this study was to investigate the validity and feasibility of loaded 5 Sit-to-Stand (5STS) force-velocity profiling compared to the gold standard instruments (isokinetic Dynamometry, ISO) and asses the relationship between the 5STS-derived muscle function indexes with clinical markers of muscle mass and strength. Forty-six older adults (21 females: 63.8 & PLUSMN; 3.9 yrs) performed 5STS (four different weight conditions) and ISO tests (five different velocities). Paired t-tests, regression analyses, and Bland-Altman analysis were conducted. The results showed significant differences in F0, V0, and Vopt (p < 0.001) but no difference in Pmax (p = 0.259) between tests. Only F0 and Pmax were highly correlated between tests (r = 0.71, r = 0.84, respectively). Bland-Altman analysis showed a not significant bias and good precision (p = 0.260, 34 W) only for Pmax. Large to very large correlations (r = 0.53 to 0.81) were found between F0 and Pmax and clinical markers of muscle mass and strength. In conclusion, loaded 5STS profiling could be a feasible, valid, and cost- and time-efficient alternative to ISO for the characterization of clinically relevant markers of muscle function in healthy older adults.
引用
收藏
页数:16
相关论文
共 43 条
  • [41] Temporal, Kinematic and Kinetic Variables Derived from a Wearable 3D Inertial Sensor to Estimate Muscle Power during the 5 Sit to Stand Test in Older Individuals: A Validation Study
    Bochicchio, Gianluca
    Ferrari, Luca
    Bottari, Alberto
    Lucertini, Francesco
    Scarton, Alessandra
    Pogliaghi, Silvia
    SENSORS, 2023, 23 (10)
  • [42] Applying both the 30-s and the 5-repetition sit-to-stand tests captures dissimilar groups and a broader spectrum of physical abilities in mobility-limited older individuals: results from the BIOFRAIL study
    Hansen, P.
    Nygaard, H.
    Ryg, J.
    Kristensen, M. T.
    Suetta, C.
    EUROPEAN GERIATRIC MEDICINE, 2024, : 703 - 707
  • [43] Estimating cutpoints of gait speed and sit-to-stand test values for self-reported mobility limitations in a cohort of community-dwelling older adults from Singapore: comparing receiver operating characteristic (ROC) analysis with adjusted predictive modelling
    Pua, Yong-Hao
    Tay, Laura
    Terluin, Berend
    Clark, Ross Allan
    Thumboo, Julian
    Tay, Ee-Ling
    Mah, Shi-Min
    Ng, Yee-Sien
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2023, 112