Safe and effective delivery of high-power, short-duration radiofrequency ablation lesions with a flexible-tip ablation catheter

被引:8
作者
Ptaszek, Leon M. [1 ,8 ]
Koruth, Jacob [2 ]
Santangeli, Pasquale [3 ]
Piccini, Jonathan P. [4 ]
Ranjan, Ravi [5 ]
Mahapatra, Srijoy [6 ]
Pipenhagen, Catherine [7 ]
Fish, Jeffrey M. [7 ]
Moon, L. Boyce [7 ]
Ambrosius, Nicholas M. [7 ]
Boudlali, Hana [7 ]
Jensen, James A. [7 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, MGH Heart Ctr, Cardiac Arrhythmia Serv, Boston, MA USA
[2] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, Dept Cardiol, New York, NY USA
[3] Hosp Univ Penn, Div Cardiovasc Med, Cardiac Electrophysiol Sect, Philadelphia, PA USA
[4] Duke Univ Hosp, Duke Clin Res Inst, Electrophysiol Sect, Durham, NC USA
[5] Univ Utah, Div Cardiovasc Med, Salt Lake City, UT USA
[6] M Hlth Fairview Univ Minnesota, Minneapolis, MN USA
[7] Abbott, Plymouth, Devon, England
[8] Massachusetts Gen Hosp, MGH Heart Ctr, Cardiac Arrhythmia Serv, 55 Fruit Str,GRB 825, Boston, MA 02114 USA
来源
HEART RHYTHM O2 | 2023年 / 4卷 / 01期
基金
美国国家卫生研究院;
关键词
Atrial fibrillation; High-power; short-duration ablation; Pulmonary vein isolation; Pulmonary vein stenosis; Radiofrequency ablation; Steam pop; PULMONARY VEIN ISOLATION; FORCE-SENSING CATHETER; ATRIAL-FIBRILLATION; TEMPERATURE; IMPACT; TRIAL; SIZE;
D O I
10.1016/j.hroo.2022.10.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND High-power, short-duration (HPSD) radiofrequency ablation (RFA) may reduce ablation time. Concerns that catheter -mounted thermocouples (TCs) can underestimate tissue tempera-ture, resulting in elevated risk of steam pop formation, potentially limit widespread adoption of HPSD ablation.OBJECTIVE The purpose of this study was to compare the safety and efficacy of HPSD and low-power, long-duration (LPLD) RFA in the context of pulmonary vein isolation (PVI).METHODS An open-irrigated ablation catheter with a contact force sensor and a flexible-tip electrode containing a TC at its distal end (TactiFlexTM Ablation Catheter, Sensor EnabledTM, Abbott) was used to isolate the left pulmonary veins (PVs) in 12 canines with HPSD RFA (50 W for 10 seconds) and LPLD RFA (30 W for a maximum of 60 seconds). PVI was assessed at 30 minutes and 28 6 3 days post -ablation. Computed tomographic scans were performed to assess PV stenosis after RFA. Lesions were evaluated with histopathology. RESULTS A total of 545 ablations were delivered: 252 with LPLD (0 steam pops) and 293 with HPSD RFA (2 steam pops) (P = .501).Ablation time required to achieve PVI was >3-fold shorter for HPSD than for LPLD RFA (P = .001). All 24 PVs were isolated 30 mi-nutes after ablation, with 12/12 LPLD-ablated and 11/12 HPSD-ablated PVs still isolated at follow-up. Histopathology revealed transmural ablations for HPSD and LPLD RFA. No major adverse events occurred. CONCLUSION An investigational ablation catheter effectively delivered RFA lesions. Ablation time required to achieve PVI with HPSD with this catheter was >3-fold shorter than with LPLD RFA.
引用
收藏
页码:42 / 50
页数:9
相关论文
共 50 条
  • [41] High-power short-duration ablation: Better, safer, and faster?
    Patel, Parin J.
    Padanilam, Benzy J.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (11) : 1576 - 1577
  • [42] The efficacy of high-power short-duration radiofrequency for atrial fibrillation ablation A protocol for systematic review and meta-analysis
    Zhang, Peng
    Ma, Ling
    Wang, Fei
    Shi, Liang
    [J]. MEDICINE, 2021, 100 (16) : E25569
  • [43] Esophageal temperature dynamics during high-power short-duration posterior wall ablation
    Barbhaiya, Chirag R.
    Kogan, Edward, V
    Jankelson, Lior
    Knotts, Robert J.
    Spinelli, Michael
    Bernstein, Scott
    Park, David
    Aizer, Anthony
    Chinitz, Larry A.
    Holmes, Douglas
    [J]. HEART RHYTHM, 2020, 17 (05) : 721 - 727
  • [44] High-power, short-duration ablation in the coronary sinus: clinical cases and preliminary observations on swine hearts
    Ma, Chengming
    Yin, Xiaomeng
    Xia, Yunlong
    Sun, Jiao
    Dai, Shiyu
    Gao, Lianjun
    Xiao, Xianjie
    Sun, Yuanjun
    Zhang, Rongfeng
    Dong, Yingxue
    Wang, Zhongzhen
    Yu, Xiaohong
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 63 (02) : 311 - 321
  • [45] Clinical experience with contact-force and flexible-tip ablation catheter designs
    N. Deubner
    H. Greiss
    E. Akkaya
    A. Berkowitsch
    S. Zaltsberg
    C. W. Hamm
    M. Kuniss
    T. Neumann
    [J]. Journal of Interventional Cardiac Electrophysiology, 2016, 47 : 75 - 82
  • [46] Meta-analysis comparing outcomes of high-power short-duration and low-power long-duration radiofrequency ablation for atrial fibrillation
    Khanra, Dibbendhu
    Hamid, Abdul
    Deshpande, Saurabh
    Mukherjee, Anindya
    Petkar, Sanjiv
    Saeed, Mohammad
    Basu-Ray, Indranill
    [J]. ANATOLIAN JOURNAL OF CARDIOLOGY, 2022, 26 (01) : 2 - +
  • [47] Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation
    Cheng, Cheng
    Xu, Banglong
    Sheng, Jianlong
    Huang, Zheng
    He, Fei
    Gao, Feng
    Wang, Xiaochen
    [J]. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2022, 2022
  • [48] High-power, short-duration ablation during Box isolation for atrial fibrillation
    Kumagai, Koichiro
    Toyama, Hideko
    [J]. JOURNAL OF ARRHYTHMIA, 2020, 36 (05) : 899 - 904
  • [49] Effect on sinus cycle length and atrioventricular node function after high-power short-duration versus conventional radiofrequency catheter ablation in paroxysmal atrial fibrillation
    Ungjeong Do
    Minsoo Kim
    Min Soo Cho
    Gi-Byoung Nam
    Kee-Joon Choi
    Jun Kim
    [J]. International Journal of Arrhythmia, 23 (1)
  • [50] Biophysical Behavior of Very High-Power Short-Duration Radiofrequency Ablation in Pulmonary Vein Isolation: Fast but Gently-Implications for a Successful Procedure
    Celentano, Eduardo
    Cristiano, Ernesto
    Ignatiuk, Barbara
    Bia, Elena
    Girotto, Lorenzo
    Tarantino, Nicola
    De Groot, Natasja M. S.
    [J]. JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)