Optimization of a flow cytometry test for routine monitoring of B cell maturation antigen targeted CAR in peripheral blood

被引:1
|
作者
Lee, Won-Ho [1 ,3 ]
Graham, Charlotte E. [1 ,2 ]
Wiggin, Hadley R. [1 ]
Nolan, Hannah K. [1 ]
Graham, Kiana J. [1 ]
Korell, Felix [1 ,2 ,3 ]
Leick, Mark B. [1 ,2 ,3 ]
Barselau, Alexis L. [1 ]
Emmanuel-Alejandro, Estelle [1 ]
Trailor, Michael A. [1 ]
Gildea, Juliane M. [1 ]
Preffer, Frederic [4 ]
Frigault, Matthew J. [1 ,2 ,3 ]
Maus, Marcela V. [1 ,2 ,3 ]
Gallagher, Kathleen M. E. [1 ,2 ,3 ,5 ]
机构
[1] Massachusetts Gen Hosp, Canc Ctr, Cellular Immunotherapy Program, Boston, MA USA
[2] Harvard Med Sch, Dept Pathol, Boston, MA USA
[3] Harvard Med Sch, Dept Med, Boston, MA USA
[4] Massachusetts Gen Hosp, Dept Pathol, Boston, MA USA
[5] Massachusetts Gen Hosp, Cellular Immunotherapy Program, Canc Ctr, Boston, MA 02129 USA
关键词
BCMA; CAR-T; flow cytometry; multiple myeloma; CILTACABTAGENE AUTOLEUCEL; SINGLE-PLATFORM; THERAPY; COUNTS;
D O I
10.1002/cyto.b.22165
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Chimeric antigen receptor (CAR) modified T cell therapies targeting BCMA have displayed impressive activity in the treatment of multiple myeloma. There are currently two FDA licensed products, ciltacabtagene autoleucel and idecabtagene vicleucel, for treating relapsed and refractory disease. Although correlative analyses performed by product manufacturers have been reported in clinical trials, there are limited options for reliable BCMA CAR T detection assays for physicians and researchers looking to explore it as a biomarker for clinical outcome. Given the known association of CAR T cell expansion kinetics with toxicity and response, being able to quantify BCMA CAR T cells routinely and accurately in the blood of patients can serve as a valuable asset. Here, we optimized an accurate and sensitive flow cytometry test using a PE-conjugated soluble BCMA protein, with a lower limit of quantitation of 0.19% of CD3+ T cells, suitable for use as a routine assay for monitoring the frequency of BCMA CAR T cells in the blood of patients receiving either ciltacabtagene autoleucel or idecabtagene vicleucel.
引用
收藏
页码:162 / 170
页数:9
相关论文
共 50 条
  • [31] CAR T Cells with Enhanced Sensitivity to B Cell Maturation Antigen for the Targeting of B Cell Non-Hodgkin's Lymphoma and Multiple Myeloma
    Bluhm, Julia
    Kieback, Elisa
    Marino, Stephen F.
    Oden, Felix
    Westermann, Joerg
    Chmielewski, Markus
    Abken, Hinrich
    Uckert, Wolfgang
    Hoepken, Uta E.
    Rehm, Armin
    MOLECULAR THERAPY, 2018, 26 (08) : 1906 - 1920
  • [32] Diagnosis of chronic B-cell lymphoproliferative disease in peripheral blood = how machine learning may help to the interpretation of flow cytometry data
    Gross, Zofia
    Veyrat-Masson, Richard
    Grange, Beatrice
    Huet, Sarah
    Verney, Aurelie
    Traverse-Glehen, Alexandra
    Ruminy, Philippe
    Baseggio, Lucile
    HEMATOLOGICAL ONCOLOGY, 2024, 42 (01)
  • [33] In vitro detection of Mycoplasma fermentans binding to B-lymphocytes in fresh peripheral blood using flow cytometry
    Cheek, RF
    Olszak, I
    Madoff, S
    Preffer, FI
    CYTOMETRY, 1997, 28 (01): : 90 - 95
  • [34] Safety and efficacy of B cell maturation antigen-directed CAR T-cell therapy in patients with relapsed/refractory multiple myeloma and concurrent light chain amyloidosis
    Goel, Utkarsh
    Dima, Danai
    Davis, James
    Ahmed, Nausheen
    Shaikh, Hira
    Lochner, Jonathan
    Abdallah, Al-Ola
    Khouri, Jack
    Hashmi, Hamza
    Anwer, Faiz
    EUROPEAN JOURNAL OF HAEMATOLOGY, 2024, 113 (06) : 817 - 823
  • [35] A new automated flow cytometry data analysis approach for the diagnostic screening of neoplastic B-cell disorders in peripheral blood samples with absolute lymphocytosis
    Costa, E. S.
    Arroyo, M. E.
    Pedreira, C. E.
    Garcia-Marcos, M. A.
    Tabernero, M. D.
    Almeida, J.
    Orfao, A.
    LEUKEMIA, 2006, 20 (07) : 1221 - 1230
  • [36] The challenge of standardizing CAR-T cell monitoring: A comparison of two flow-cytometry methods and correlation with qPCR technique
    Shephard, Juan Luis Valdivieso
    Perez, Elisabet Matas
    Bujalance, Silvia Garcia
    Aguilar, Isabel Mirones
    Martinez, Berta Gonzalez
    Martinez, Antonio Perez
    Granados, Eduardo Lopez
    Feito, Ana Martinez
    Zapardiel, Elena Sanchez
    CYTOMETRY PART A, 2024, 105 (05) : 368 - 375
  • [37] A new automated flow cytometry data analysis approach for the diagnostic screening of neoplastic B-cell disorders in peripheral blood samples with absolute lymphocytosis
    E S Costa
    M E Arroyo
    C E Pedreira
    M A García-Marcos
    M D Tabernero
    J Almeida
    A Orfao
    Leukemia, 2006, 20 : 1221 - 1230
  • [38] Determination of mononuclear cell count using peripheral smear and flow cytometry in peripheral blood stem cell products: A retrospective study from an Indian cancer center
    Krishnan, Aswathi
    Murugesan, Mohandoss
    Therayangalath, Bindu
    Philip, Kandathil Joseph
    Nayanar, Sangeetha
    Nair, Chandran
    ASIAN JOURNAL OF TRANSFUSION SCIENCE, 2021, 15 (02) : 151 - 156
  • [39] The application of CD73 in minimal residual disease monitoring using flow cytometry in B-cell acute lymphoblastic leukemia
    Wang, Wei
    Gao, Li
    Li, Yan
    Li, Zhen-Ling
    Gong, Ming
    Huang, Fan-Zhou
    Chen, Yan-Rong
    Zhang, Chun-Xia
    Gao, Ya-Yue
    Ma, Yi-Gai
    LEUKEMIA & LYMPHOMA, 2016, 57 (05) : 1174 - 1181
  • [40] Biclonal Low-Grade B Cell Lymphoma as Detected by Multiparametric Flow Cytometry in Blood and Marrow
    Ramalingam, Thulasi Raman
    Muralikrishnan, Srikanth
    Easow, Jose
    Vaidhyanathan, Lakshman
    INDIAN JOURNAL OF HEMATOLOGY AND BLOOD TRANSFUSION, 2023, 39 (04) : 691 - 698