Validation and Development of a Method for Identification and Stability Analysis of Delafloxacin Separation Using LC-MS/MS

被引:0
作者
Sarbudeen, M. [1 ]
Abbaraju, V. D. N. Kumar [2 ]
Padmalatha, K. [3 ]
Kodali, Unati Sai [4 ]
Chinnamaneni, Satya Vani [5 ]
Mandava, Bhuvantej [6 ]
Rao, Mandava Venkata Basaveswarao [2 ]
机构
[1] Krishna Univ, Dept Chem, Machilipatnam 521004, Andhra Pradesh, India
[2] GITAM Univ, Dept Environm Sci, Visakhapatnam 521108, Andhra Pradesh, India
[3] Vijaya Inst Pharmaceut Sci Women, Vijayawada 521108, India
[4] Dr NTR Univ Hlth Sci, Dr Pinnamaneni Siddhartha Inst Med Sci & Res Fdn, Vijayawada, Andhra Pradesh, India
[5] Waters Corp, Principal QC Lab Tech, Milford, MA USA
[6] Sacred Heart Univ, Dept Healthcare informat, 5151 Pk Ave, Fair Fields, CT 06825 USA
关键词
LC-MS/MS; Validation; Linearity; Nano gram; MRM ion modeDelafloxacin; PLASMA;
D O I
10.13005/ojc/400112
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In order todevelop and validate the technique for delafloxacin authors are used the peak intense which is furthermore improved to this present investigation employing a variety of parameters, which includes column, alteration of eluent ratio, and rate of flow. For this development authors are usedWaters column with 2.1mmx100mm, 5 mu m, C18. Mobile phase as 0.2% formic acid with pH of 2.6 and acetonitrile in the proportion of 30v/v:70v/v. The retention was 1.2 min and the rate of flow is identified as 0.12 mu L/minute. Forced degradation studies reveals that the peaksobtained are homogeneousand there are noco-elutingpeaks. The %RSD was found to be 3.5. Six LLOQ concentrations (10 ng/ml-1)of delafloxacin were evaluated in order to carry out the precision study. The results of calibration curve were 232.8, 0.9968, and 1273, respectivelyfor slope, coefficient of correlation (r2), and intercept.Mass spectrum development is done by the utilization of MRM ion mode (ES+) with mass transitions of m/z 441.10>379.10 (amu). On ionization,both parent and daughter ions were identified. 10-150 ng/mL is the calibration curve which reveals that linear by lower quantification limit of 10.00 ng/mL. LOQ- 50.00 ng/mL, MOQ-100.00 ng/mL, HOQ-150.00 ng/mL set to accuracy studies.In this present study, the research could be very helpful inlocating other potential DPs and process -related impurities that might be present indelafloxacin in very small amounts.
引用
收藏
页码:95 / 101
页数:7
相关论文
共 50 条
  • [31] Development and validation of LC-MS/MS method to determine the residue of veterinary drugs ivermectin, doramectin and moxidectin in milk
    Dahiya, Meenakshi
    Dubey, Nidhi
    Singh, Prabha
    Singh, G. N.
    INDIAN JOURNAL OF CHEMISTRY SECTION B-ORGANIC CHEMISTRY INCLUDING MEDICINAL CHEMISTRY, 2013, 52 (10): : 1313 - 1317
  • [32] Method development and validation of testosterone in muscle by using LC-MS/MS in positive ESI mode
    Dahiya, Meenakshi
    Dubey, Nidhi
    Singh, Prabha
    Singh, G. N.
    INDIAN JOURNAL OF CHEMISTRY SECTION B-ORGANIC CHEMISTRY INCLUDING MEDICINAL CHEMISTRY, 2013, 52 (04): : 573 - 578
  • [33] Development and validation of LC-MS/MS method for the determination of cyproheptadine in several pharmaceutical syrup formulations
    Feas, Xesus
    Ye, Lei
    Hosseini, Seyed V.
    Fente, Cristina A.
    Cepeda, Alberto
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) : 1044 - 1049
  • [34] Development and validation of a sensitive and selective LC-MS/MS method for determination of tacrolimus in oral fluids
    Ghareeb, Mwlod
    Akhlaghi, Fatemeh
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1038 : 136 - 141
  • [35] Development and validation of a rapid method for microcystins in fish and comparing LC-MS/MS results with ELISA
    Geis-Asteggiante, Lucia
    Lehotay, Steven J.
    Fortis, Laurie L.
    Paoli, George
    Wijey, Chandi
    Heinzen, Horacio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (08) : 2617 - 2630
  • [36] Development And Validation Of Sensitive LC-MS/MS Method For Determination Of Doravirine In Human Plasma Samples
    Bhadru, Banothu
    Rao, V. Venkata
    Vidyadhara, Suryadevara
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2020, 10 (03): : P29 - P35
  • [37] Development and validation of a LC-MS/MS method for quantification of hetrombopag for pharmacokinetics study
    Chen, Tao
    Chen, Zhonghua
    Zhang, Suxing
    Zhang, Kezhi
    Wang, Laiyou
    SPRINGERPLUS, 2015, 4
  • [38] Development and validation of a rapid method for microcystins in fish and comparing LC-MS/MS results with ELISA
    Lucía Geis-Asteggiante
    Steven J. Lehotay
    Laurie L. Fortis
    George Paoli
    Chandi Wijey
    Horacio Heinzen
    Analytical and Bioanalytical Chemistry, 2011, 401 : 2617 - 2630
  • [39] Development and validation of an LC-MS/MS method for simultaneously determining doxapram and keto-doxapram in human serum
    Suzuki, Yuki
    Kamada, Noboru
    Ohno, Hitoshi
    Abe, Yoshikazu
    Endo, Takuro
    Kobayashi, Mamoru
    BIOANALYSIS, 2017, 9 (06) : 503 - 515
  • [40] Development and validation of a LC-MS/MS method for simultaneous quantification of Ivabradine and Metoprolol in rat plasma
    Eswarudu, M. Mukkanti
    Rao, A. Lakshmana
    Vijay, K.
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2022, 116