Quantitative Analysis of Cr(III) and Cr(VI) Using Gold Nanoparticles with UV-Vis Spectrometry and Smartphone Colorimetric-Sensing

被引:0
|
作者
Firdaus, M. Lutfi [1 ]
Apriyoanda, Hadi [1 ]
Isnan, Ibrahim [1 ]
Wyantuti, Santhy [2 ]
Eddy, Diana Rokhmawaty [2 ]
机构
[1] Univ Bengkulu, Grad Sch Sci Educ, Bengkulu 38371, Indonesia
[2] Univ Padjadjaran, Dept Chem, Bandung 45363, Indonesia
来源
IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION | 2023年 / 42卷 / 03期
关键词
Cr speciation; Trivalent chromium; Hexavalent chromium; Gold nanoparticles; Digital image colorimetry; DIC; Smartphone; CHROMIUM; SPECIATION; SAMPLES;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Analysis and speciation of chromium ions are important due to the contrasting nature of essential Cr(III) and toxic Cr(VI) ions. Here, the first simultaneous determination of Cr(III) and Cr(VI) ions is introduced using gold nanoparticles (AuNPs) as a colorimetric agent and subsequent detection using an application attached to a smartphone, in addition to the UV-vis spectrometer. A small amount of AuNPs (1 mM) was used as a result of its excellent selectivity and sensitivity toward Cr(III) and Cr(VI) ions. The color change of AuNPs was monitored using a smartphone and validated by a UV-vis spectrometer. The peak absorbance of AuNPs' surface plasmon resonance (520 nm) was red-shifted to 630 nm when Cr(III) was introduced, while it was blue-shifted to 370 nm when Cr(VI) was added to the system. The absorbance shifts of the system produce a color change that is linearly proportional to the Cr concentration. At pH 5.0, a linear relationship of Cr(III) occurred at an absorbance ratio of 630/520 nm in the concentration range of 0.2-1.0 ppm (R-2 = 0.9911), while those of Cr(VI) at an absorbance of 370 nm in the concentration range of 0.05-1.0 ppm (R-2 = 0.9909). The method's detection limit of UV-Vis spectrometer was found to be 0.051 ppm (0.98 uM) and 0.035 ppm (0.67 uM) for Cr(III) and Cr(VI), respectively. The detection limit of smartphone-digital image colorimetry compared to UV-vis spectrometer was better at about 22%. Finally, the proposed method was tested to analyze Cr concentration in actual samples (drinking and tap water) that give satisfactory accuracy (< 2.0%) and precision (< 5.0%).
引用
收藏
页码:722 / 730
页数:9
相关论文
共 50 条
  • [41] Ultra-trace speciation analysis of Cr(III) and Cr(VI) in rice using species-specific isotope dilution and HPLC-ICP-MS
    Saraiva, Marina
    Guerin, Thierry
    Jitaru, Petru
    Sloth, Jens J.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2021, 38 (10): : 1735 - 1742
  • [42] Analysis of the bioavailability of Cr(III) and Cr(VI) based on the determination of chromium in Mentha piperita by graphite furnace atomic absorption spectrometry
    Dogo, Svetlana
    Razic, Slavica
    Manojlovic, Dragan
    Slavkovic, Latinka
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2011, 76 (01) : 143 - 153
  • [43] Electrochemical detection of Cr(III) and Cr(VI) in solution by using ZrO2 modified magnetic nanoparticles by redox probes
    Bagherzadeh, Mojtaba
    Hadizadeh, Zahra
    Akrami, Zakyeh
    Ghahfarokhi, Zahra Shams
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2021, 131
  • [44] Colorimetric detection of Cr3+ in dietary supplements using a smartphone based on EDTA and tannic acid-modified silver nanoparticles
    Sangsin, Supanee
    Srivilai, Piyarat
    Tongraung, Pan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 246
  • [45] Photocatalytic reduction of Cr(VI) in the presence of citric acid over perovskite type SO42-/TBBFS under UV-vis light irradiation
    Lei, Xue-fei
    Xue, Xiang-xin
    ENVIRONMENT MATERIALS AND ENVIRONMENT MANAGEMENT PTS 1-3, 2010, 113-116 : 1632 - +
  • [46] Simultaneous Determination of Trace Cr(III) and Cr(VI) in Water Using Ion-Pairing Reversed Phase Chromatography-Inductively Coupled Plasma Mass Spectrometry
    Wang Hua-Jian
    Li Yan-Hong
    Feng Wei-Yue
    Wang Meng
    Jia Guang
    Wang Bing
    Zhu Mo-Tao
    Wang Yun
    Chai Zhi-Fang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (03) : 433 - 436
  • [47] Red-to-blue colorimetric detection of chromium via Cr (III)-citrate chelating based on Tween 20-stabilized gold nanoparticles
    Wang, Xiaokun
    Wei, Yingqin
    Wang, Shasha
    Chen, Lingxin
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2015, 472 : 57 - 62
  • [48] Polyvinylalcohol-citrate-stabilized gold nanoparticles supported congo red indicator as an optical sensor for selective colorimetric determination of Cr(III) ion
    Amourizi, Fereshteh
    Dashtian, Kheibar
    Ghaedi, Mehrorang
    POLYHEDRON, 2020, 176
  • [49] Colorimetric and smartphone-integrated paper device for on-site determination of arsenic (III) using sucrose modified gold nanoparticles as a nanoprobe
    Shrivas, Kamlesh
    Patel, Sanyukta
    Sinha, Deepak
    Thakur, Santosh Singh
    Patle, Tarun Kumar
    Kant, Tushar
    Dewangan, Khemchand
    Satnami, Manmohan L.
    Nirmalkar, Jayant
    Kumar, Suneel
    MICROCHIMICA ACTA, 2020, 187 (03)
  • [50] Determination of Cr(VI) and Cr(III) species in parenteral solutions using a nanostructured material packed-microcolumn and electrothermal atomic absorption spectrometry
    Monasterio, Romina P.
    Lascalea, Gustavo E.
    Martinez, Luis D.
    Wuilloud, Rodolfo G.
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2009, 23 (03) : 157 - 166