Quantitative Analysis of Cr(III) and Cr(VI) Using Gold Nanoparticles with UV-Vis Spectrometry and Smartphone Colorimetric-Sensing

被引:0
|
作者
Firdaus, M. Lutfi [1 ]
Apriyoanda, Hadi [1 ]
Isnan, Ibrahim [1 ]
Wyantuti, Santhy [2 ]
Eddy, Diana Rokhmawaty [2 ]
机构
[1] Univ Bengkulu, Grad Sch Sci Educ, Bengkulu 38371, Indonesia
[2] Univ Padjadjaran, Dept Chem, Bandung 45363, Indonesia
来源
IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION | 2023年 / 42卷 / 03期
关键词
Cr speciation; Trivalent chromium; Hexavalent chromium; Gold nanoparticles; Digital image colorimetry; DIC; Smartphone; CHROMIUM; SPECIATION; SAMPLES;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Analysis and speciation of chromium ions are important due to the contrasting nature of essential Cr(III) and toxic Cr(VI) ions. Here, the first simultaneous determination of Cr(III) and Cr(VI) ions is introduced using gold nanoparticles (AuNPs) as a colorimetric agent and subsequent detection using an application attached to a smartphone, in addition to the UV-vis spectrometer. A small amount of AuNPs (1 mM) was used as a result of its excellent selectivity and sensitivity toward Cr(III) and Cr(VI) ions. The color change of AuNPs was monitored using a smartphone and validated by a UV-vis spectrometer. The peak absorbance of AuNPs' surface plasmon resonance (520 nm) was red-shifted to 630 nm when Cr(III) was introduced, while it was blue-shifted to 370 nm when Cr(VI) was added to the system. The absorbance shifts of the system produce a color change that is linearly proportional to the Cr concentration. At pH 5.0, a linear relationship of Cr(III) occurred at an absorbance ratio of 630/520 nm in the concentration range of 0.2-1.0 ppm (R-2 = 0.9911), while those of Cr(VI) at an absorbance of 370 nm in the concentration range of 0.05-1.0 ppm (R-2 = 0.9909). The method's detection limit of UV-Vis spectrometer was found to be 0.051 ppm (0.98 uM) and 0.035 ppm (0.67 uM) for Cr(III) and Cr(VI), respectively. The detection limit of smartphone-digital image colorimetry compared to UV-vis spectrometer was better at about 22%. Finally, the proposed method was tested to analyze Cr concentration in actual samples (drinking and tap water) that give satisfactory accuracy (< 2.0%) and precision (< 5.0%).
引用
收藏
页码:722 / 730
页数:9
相关论文
共 50 条
  • [21] Selective colorimetric detection of Cr(VI) using starch-stabilized silver nanoparticles and application for chromium speciation
    Sapyen, Wannida
    Toonchue, Saowanee
    Praphairaksit, Narong
    Imyim, Apichat
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 274
  • [22] Speciation of Cr(III) and Cr(VI) in environmental samples by using coprecipitation with praseodymium(III) hydroxide and determination by flame atomic absorption spectrometry
    Soylak, Mustafa
    Aydin, Ayse
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2012, 9 (03) : 263 - 267
  • [23] Speciation of Cr(III) and Cr(VI) in environmental samples by using coprecipitation with praseodymium(III) hydroxide and determination by flame atomic absorption spectrometry
    Mustafa Soylak
    Ayse Aydin
    Journal of the Iranian Chemical Society, 2012, 9 : 263 - 267
  • [24] Efficient removal of Cr(III)-organic complexes from water using UV/Fe(III) system: Negligible Cr(VI) accumulation and mechanism
    Ye, Yuxuan
    Jiang, Zhao
    Xu, Zhe
    Zhang, Xiaolin
    Wang, Dandan
    Lv, Lu
    Pan, Bingcai
    WATER RESEARCH, 2017, 126 : 172 - 178
  • [25] Biogenic unmodified gold nanoparticles for selective and quantitative detection of cerium using UV-vis spectroscopy and photon correlation spectroscopy (DLS)
    Priyadarshini, E.
    Pradhan, N.
    Panda, P. K.
    Mishra, B. K.
    BIOSENSORS & BIOELECTRONICS, 2015, 68 : 598 - 603
  • [26] An Accurate Sensing Technique for Estimation and Detection of Cr(III) in Water by Using Smartphone
    Hazarika, Udeshna
    Roy, Ram Kishore
    Bezboruah, Tulshi
    IEEE SENSORS LETTERS, 2023, 7 (02)
  • [27] Voltammetric determination of Cr(VI) using gold nanoparticles-modified glassy carbon electrode
    Wyantuti, Santhy
    Ishmayana, Safri
    Hartati, Yeni Wahyuni
    INTERNATIONAL SYMPOSIUM ON APPLIED CHEMISTRY 2015, 2015, 16 : 15 - 23
  • [28] A submicromolar Cr(III) sensor with a complex of methionine using gold nanoparticles
    Nguyen Hoang Ly
    Oh, Cheol H.
    Joo, Sang-Woo
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 219 : 276 - 282
  • [29] Solid-phase extraction of Cr(VI) with magnetic melamine?formaldehyde resins, followed by its colorimetric sensing using gold nanoparticles modified with p-amino hippuric acid
    Avan, Asiye Aslihan
    Filik, Hayati
    Demirata, Birsen
    MICROCHEMICAL JOURNAL, 2021, 164
  • [30] Speciation of Cr(III) and Cr(VI) using solid phase extraction and determination of total As inductively coupled plasma atomic emission spectrometry
    Zachariadis, George A.
    Trikas, Evaggelos
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (04) : 375 - 381