Effect of prefabricated auxiliary devices and scanning patterns on the accuracy of complete-arch implant digital impressions

被引:6
作者
Wu, Hio Kuan [1 ]
Chen, Guanhui [2 ]
Wang, Jing [3 ]
Zhang, Zhengchuan [1 ]
Huang, Xiaoqiong [1 ]
Lin, Xiaoxuan [1 ]
Deng, Feilong [1 ]
Li, Yiming [1 ]
机构
[1] Sun Yat sen Univ, Hosp Stomatol, Guanghua Sch Stomatol, Guangdong Prov Key Lab Stomatol, Guangzhou 510055, Peoples R China
[2] Sun Yat sen Univ, Affiliated Hosp 7, Dept Stomatol, Shenzhen 518107, Guangdong, Peoples R China
[3] YangHe Dent Clin, Guangzhou 510055, Peoples R China
基金
中国国家自然科学基金;
关键词
Accuracy; Dental implant; Digital impression; Intraoral scanner; Scan body; Scanning patterns; STRATEGIES; IMPACT;
D O I
10.1016/j.jdent.2023.104788
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study aimed to evaluate the impact of prefabricated auxiliary devices (PAD) and scanning pat-terns on the accuracy of complete-arch implant digital impressions.Methods: An edentulous maxillary model was inserted with four parallel implant analogs and four PAD. The model was scanned with D2000 dental laboratory scanner as the reference scans. Test scans were obtained by 8 different scanning patterns (SP), which including SPA, SPB, SPC, SPD, SPE, SPF, SPG and SPH, with (test group) or without (control group) using the PAD by an intraoral scanner (Aoralscan 3, 3DShining). SPA was the scanning pattern recommended by the manufacturer. Each scanning time was recorded. The related files were imported into inspection software for assessment. Aligned Ranks Transformation ANOVA, Kruskal-Wallis and Mann-Whitney tests were used to evaluate the values. The level of significance was set at alpha = 0.05.Results: The scanning patterns significantly influenced the linear accuracy in the test group and the scanning time for both groups. Lower linear trueness in the test group was found in SPF (p<0.05) and SPG (p<0.05). Longer scanning time was found in SPB and SPG for both groups. The test group demonstrated linear accuracy enhancement in all the scanning patterns; angular trueness enhancement was seen in SPA (p<0.05), SPC (p<0.01) and SPH (p<0.01). Significant longer scanning time was found in SPB (p<0.05), SPF (p<0.05), SPG (p<0.05) and SPH (p<0.05) when using PAD.Conclusion: The scanning patterns impact the accuracy differently depending on the PAD's existence. The scanning time can be significantly influenced by the scanning patterns and the PAD.
引用
收藏
页数:11
相关论文
共 46 条
  • [1] Effect of scanning speed, scanning pattern, and tip size on the accuracy of intraoral digital scans
    An, Hongseok
    Langas, Eleni E.
    Gill, Aria S.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06) : 1160 - 1167
  • [2] Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trial
    Arcuri, Lorenzo
    Pozzi, Alessandro
    Lio, Fabrizio
    Rompen, Eric
    Zechner, Werner
    Nardi, Alessandra
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (02) : 128 - 136
  • [3] Effect of saliva isolation and intraoral light levels on performance of intraoral scanners
    Camc, Hasan
    Salmanpour, Farhad
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2020, 158 (05) : 759 - 766
  • [4] The accuracy of computer-guided implant surgery with tooth-supported, digitally designed drill guides based on CBCT and intraoral scanning. A prospective cohort study
    Derksen, Wiebe
    Wismeijer, Daniel
    Fluegge, Tabea
    Hassan, Bassam
    Tahmaseb, Ali
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (10) : 1005 - 1015
  • [5] Fiore A.D., 2021, Euras. J. Health, V1, P37, DOI [10.17932/EJOH.2020.022/ejoh_v01i1003, DOI 10.17932/EJOH.2020.022/EJOH_V01I1003]
  • [6] The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis
    Fluegge, Tabea
    van der Meer, Wicher Joerd
    Gonzalez, Beatriz Gimenez
    Vach, Kirstin
    Wismeijer, Daniel
    Wang, Ping
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 374 - 392
  • [7] A systematic review of digital removable partial dentures. Part I: Clinical evidence, digital impression, and maxillomandibular relationship record
    Fueki, Kenji
    Inamochi, Yuka
    Wada, Junichiro
    Arai, Yuki
    Takaichi, Atsushi
    Murakami, Natsuko
    Ueno, Takeshi
    Wakabayashi, Noriyuki
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (01) : 40 - 52
  • [8] Patient outcomes and procedure working time for digital versus conventional impressions: A systematic review
    Gallardo, Yolanda R.
    Bohner, Lauren
    Tortamano, Pedro
    Pigozzo, Monica N.
    Lagana, Dalva C.
    Sesma, Newton
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (02) : 214 - 219
  • [9] Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete-arch intraoral digital implant scans
    Gomez-Polo, Miguel
    Cascos, Rocio
    Ortega, Rocio
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (06) : 591 - 601
  • [10] Accuracy, scanning time, and number of photograms of various scanning patterns for the extraoral digitalization of complete dentures by using an intraoral scanner
    Gomez-Polo, Miguel
    Cimolai, Augusto
    Ortega, Rocio
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03) : 521 - 528