Thermohydraulic Efficiency of a Solar Air Heater in the Presence of Graded Aluminium Wire Mesh-A Combined Experimental-Numerical Study

被引:4
作者
Diganjit, Rawal [1 ]
Gnanasekaran, Nagaranjan [1 ]
Mobedi, Moghtada [2 ]
机构
[1] Natl Inst Technol, Dept Mech Engn, Mangalore 575025, India
[2] Shizuoka Univ, Fac Engn, Mech Engn Dept, 3-5-1 Johoku,Naka Ku, Hamamatsu 4328561, Japan
关键词
solar air heater; graded aluminium wire mesh; local thermal equilibrium; Rosseland radiation model; thermohydraulic performance parameter; thermohydraulic efficiency; THERMAL PERFORMANCE; EXERGETIC PERFORMANCE; FLUID-FLOW; COLLECTOR; DRYER; IMPROVEMENT; CFD; ENHANCEMENT; TOPOLOGY; DESIGN;
D O I
10.3390/en16155633
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this work, aluminium wire mesh (WM) samples with 3, 9, and 18 pores per inch (PPI) and porosities of 0.894, 0.812, and 0.917, respectively, were combined together to form graded structures including 3-9-18, 9-18-3, and 18-3-9 PPIs. A 5 mm thickness for each WM was considered for a length of 2 m and inserted into a single-pass solar air heater (SAH) in which the height of the SAH was 120 mm. For the numerical analysis, a 3D numerical model was considered in ANSYS fluent software, and the Rosseland radiation model renormalization group (RNG) k-& epsilon; enhanced wall function was incorporated to account for solar radiation. The local thermal equilibrium (LTE) model was considered to obtain the heat-transfer characteristics of the WM. The numerical results of the thermohydraulic performance parameter (THPP) of the 9-18-3 PPI WM were 13.04% and 11.92% higher than the 3-9-18 and 18-3-9 PPI samples, respectively. Later, 25% of the 9-18-3 graded wire mesh (GWM) was considered at four different locations, i.e., 0, 0.5, 1, and 1.5 m away from the inlet, and analysed to obtain the best location for efficient heat transfer. The computational results show that 1.5 m away from the inlet is the best location among the different locations considered. The experimental results of the GWM at 1.5 m away from the inlet demonstrated a 20.91% and 23.32% increase in thermal efficiency compared to the empty channel for the 0.027 kg/s and 0.058 kg/s mass flow rates, respectively. From numerical-cum-experimental analysis, it was found that inserting 25% length of GWM of the entire length of the test section at a distance of 1.5 m from the inlet in single pass SAH improves the overall performance of the empty channel of single-pass SAH.
引用
收藏
页数:32
相关论文
共 73 条
[51]   Simulation and experimental investigation of fluid flow in porous and non-porous solar air heaters [J].
Rajarajeswari, K. ;
Alok, Praveen ;
Sreekumar, A. .
SOLAR ENERGY, 2018, 171 :258-270
[52]  
Ranake Vinayak Data Loggers, WIR DAT LOGG CHART R
[53]   Performance evaluation of a flat-plate solar collector filled with porous metal foam: Experimental and numerical analysis [J].
Saedodin, S. ;
Zamzamian, S. A. H. ;
Nimvari, M. Eshagh ;
Wongwises, S. ;
Jouybari, H. Javaniyan .
ENERGY CONVERSION AND MANAGEMENT, 2017, 153 :278-287
[54]   Thermo-hydraulic performance of a solar air heater with staggered C-shape finned absorber plate [J].
Saravanan, A. ;
Murugan, M. ;
Reddy, M. Sreenivasa ;
Ranjit, P. S. ;
Elumalai, P., V ;
Kumar, Pramod ;
Sree, S. Rama .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 168
[55]  
Sharma S.P., 2017, APPL SCI, V4, P90
[56]   THERMAL PERFORMANCE OF PACKED-BED SOLAR AIR HEATERS [J].
SHARMA, SP ;
SAINI, JS ;
VARMA, HK .
SOLAR ENERGY, 1991, 47 (02) :59-67
[57]  
Siegel R., 2002, Thermal radiation heat transfer
[58]   Effects of thermal conductivity and geometry of materials on the temperature variation in packed bed solar air heater [J].
Singh, Omendra Kumar ;
Panwar, N. L. .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2013, 111 (01) :839-847
[59]   Utilising fractional porous interface for high thermal performance of serpentine wavy channel solar air heater [J].
Singh, Satyender .
APPLIED THERMAL ENGINEERING, 2022, 205
[60]   Experimental and numerical investigations of a single and double pass porous serpentine wavy wiremesh packed bed solar air heater [J].
Singh, Satyender .
RENEWABLE ENERGY, 2020, 145 :1361-1387