Thermohydraulic Efficiency of a Solar Air Heater in the Presence of Graded Aluminium Wire Mesh-A Combined Experimental-Numerical Study

被引:4
作者
Diganjit, Rawal [1 ]
Gnanasekaran, Nagaranjan [1 ]
Mobedi, Moghtada [2 ]
机构
[1] Natl Inst Technol, Dept Mech Engn, Mangalore 575025, India
[2] Shizuoka Univ, Fac Engn, Mech Engn Dept, 3-5-1 Johoku,Naka Ku, Hamamatsu 4328561, Japan
关键词
solar air heater; graded aluminium wire mesh; local thermal equilibrium; Rosseland radiation model; thermohydraulic performance parameter; thermohydraulic efficiency; THERMAL PERFORMANCE; EXERGETIC PERFORMANCE; FLUID-FLOW; COLLECTOR; DRYER; IMPROVEMENT; CFD; ENHANCEMENT; TOPOLOGY; DESIGN;
D O I
10.3390/en16155633
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this work, aluminium wire mesh (WM) samples with 3, 9, and 18 pores per inch (PPI) and porosities of 0.894, 0.812, and 0.917, respectively, were combined together to form graded structures including 3-9-18, 9-18-3, and 18-3-9 PPIs. A 5 mm thickness for each WM was considered for a length of 2 m and inserted into a single-pass solar air heater (SAH) in which the height of the SAH was 120 mm. For the numerical analysis, a 3D numerical model was considered in ANSYS fluent software, and the Rosseland radiation model renormalization group (RNG) k-& epsilon; enhanced wall function was incorporated to account for solar radiation. The local thermal equilibrium (LTE) model was considered to obtain the heat-transfer characteristics of the WM. The numerical results of the thermohydraulic performance parameter (THPP) of the 9-18-3 PPI WM were 13.04% and 11.92% higher than the 3-9-18 and 18-3-9 PPI samples, respectively. Later, 25% of the 9-18-3 graded wire mesh (GWM) was considered at four different locations, i.e., 0, 0.5, 1, and 1.5 m away from the inlet, and analysed to obtain the best location for efficient heat transfer. The computational results show that 1.5 m away from the inlet is the best location among the different locations considered. The experimental results of the GWM at 1.5 m away from the inlet demonstrated a 20.91% and 23.32% increase in thermal efficiency compared to the empty channel for the 0.027 kg/s and 0.058 kg/s mass flow rates, respectively. From numerical-cum-experimental analysis, it was found that inserting 25% length of GWM of the entire length of the test section at a distance of 1.5 m from the inlet in single pass SAH improves the overall performance of the empty channel of single-pass SAH.
引用
收藏
页数:32
相关论文
共 73 条
  • [1] Comparative study of single and multi-layered packed-bed thermal energy storage systems for CSP plants
    Abdulla A.
    Reddy K.S.
    [J]. Applied Solar Energy, 2017, 53 (3) : 276 - 286
  • [2] Models for New Corrugated and Porous Solar Air Collectors under Transient Operation
    Abed, Qahtan Adnan
    Badescu, Viorel
    Ciocanea, Adrian
    Soriga, Iuliana
    Buretea, Dorin
    [J]. JOURNAL OF NON-EQUILIBRIUM THERMODYNAMICS, 2017, 42 (01) : 79 - 97
  • [3] Thermohydraulic performance of packed-bed solar air heaters
    Ahmad, A
    Saini, JS
    Varma, HK
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1996, 37 (02) : 205 - 214
  • [4] Single and double pass solar air heaters with wire mesh as packing bed
    Aldabbagh, L. B. Y.
    Egelioglu, F.
    Ilkan, M.
    [J]. ENERGY, 2010, 35 (09) : 3783 - 3787
  • [5] Numerical study on performance improvement of a flat-plate solar collector filled with porous foam
    Anirudh, K.
    Dhinakaran, S.
    [J]. RENEWABLE ENERGY, 2020, 147 : 1704 - 1717
  • [6] Performance improvement of a flat-plate solar collector by inserting intermittent porous blocks
    Anirudh, K.
    Dhinakaran, S.
    [J]. RENEWABLE ENERGY, 2020, 145 (145) : 428 - 441
  • [7] [Anonymous], 2022, ANS FLUENT R2 STUD V
  • [8] Modelling strategies for porous structures as solar receivers in central receiver systems: A review
    Avila-Marin, A. L.
    Fernandez-Reche, J.
    Martinez-Tarifa, A.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2019, 111 (15-33) : 15 - 33
  • [9] Study of solar air heater with discrete arc ribs geometry: Experimental and numerical approach
    Azad, Rajnish
    Bhuvad, Sushant
    Lanjewar, Atul
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 167
  • [10] Forced Convective Heat Transfer in a Channel Filled With a Functionally Graded Metal Foam Matrix
    Bai, Xiaohui
    Kuwahara, Fujio
    Mobedi, Moghtada
    Nakayama, Akira
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2018, 140 (11):