Predictors for adverse events during cardiac lead extraction - Experience from a large single centre

被引:0
作者
Xiao, Zengli [1 ]
He, Jinshan [2 ]
Du, Anqi [1 ]
Yang, Dandan [2 ]
An, Youzhong [1 ]
Li, Xuebin [2 ]
机构
[1] Peking Univ Peoples Hosp, Intens Care Unit, Beijing, Peoples R China
[2] Peking Univ Peoples Hosp, Cardiovasc Dept, Beijing, Peoples R China
关键词
Cardiovascular implantable electronic device; Transvenous lead extraction; Adverse events; Nomogram; EXPERT CONSENSUS STATEMENT; COMPLICATIONS; OUTCOMES; PACEMAKER; REGISTRY; REMOVAL;
D O I
10.1016/j.ijcard.2022.10.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: As the use of cardiac implantable electronic devices (CIED) has increased in recent years, the need for transvenous lead extraction (TLE) has also steadily increased. However, the TLE procedure could lead to serious complications and even death. Clinical decision-making tools are necessary for predicting these adverse events, but the appropriate tools have not yet been developed. Objective: To explore the possible predictors and develop a clinical model to predict TLE related adverse events. Methods: All the patients who were admitted to our cardiac center for TLE from January 2014 to January 2021 were included in this study. The patient information, device baseline characteristics, procedure-related information, complications and outcomes were recorded. Independent predictors of TLE related adverse events were identified by univariate, LASSO and multivariate analysis. A nomogram for predicting these adverse events was developed based on these independent predictors. Calibration and decision curve analysis were conducted to evaluate the nomogram. Results: One thousand and one hundred patients were included in this study, 778 (70.7%) were male and the median age was 68 years old. A total of 2,208 leads were extracted and 2.01 +/- 0.74 leads were extracted per procedure. Fifty-five patients (5%) developed adverse events including minor complications (2.4%), major complications (2.3%) and death (0.27%). Seven independent predictors for TLE related adverse events were identified and selected to establish the nomogram including BMI, female gender, hypoalbuminemia, number of extracted leads>3, longest dwell time of the extracted leads and manual traction. The area under the receiver operating characteristic (ROC) curve (AUC) for the prediction model was 0.774. Calibration curve and decision curve analysis showed that the nomogram had good prediction performance. Conclusion: TLE related adverse events are some of the key issues that concern clinicians. We have identified seven independent factors and established a predictive model that may help clinicians identify at-risk patients and create better plans for lead extraction.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
[41]   Lead Removal Without Extraction Tools: A Single-Center Experience [J].
Lima, Neiberg de Alcantara ;
Cunha, Gisele Schinaider ;
de Menezes, Natalia Soares ;
da Silva Junior, Evilasio Leobino ;
de Vasconcelos Lima, Carol Cavalcante ;
Vitorino Sampaio, Stela Maria .
BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2019, 34 (04) :458-463
[42]   Predictors for a successful external cephalic version: a single centre experience [J].
Ebner, Florian ;
Friedl, Thomas W. P. ;
Leinert, Elena ;
Schramm, Amelie ;
Reister, Frank ;
Lato, Kristian ;
Janni, Wolfgang ;
DeGregorio, Nikolaus .
ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2016, 293 (04) :749-755
[43]   A novel nomogram for predicting respiratory adverse events during transport after interventional cardiac catheterization in children [J].
Tong, Chaoyang ;
Liu, Peiwen ;
Zhang, Kan ;
Liu, Ting ;
Zheng, Jijian .
FRONTIERS IN PEDIATRICS, 2022, 10
[44]   Large, single-center, single-operator experience with transvenous lead extraction: Outcomes and changing indications [J].
Jones, Samuel O. ;
Eckart, Robert E. ;
Albert, Christine M. ;
Epstein, Laurence M. .
HEART RHYTHM, 2008, 5 (04) :520-525
[45]   Hybrid transvenous lead extraction during cardiac surgery for valvular endocarditis [J].
Yildirim, Yalin ;
Petersen, Johannes ;
Toennis, Tobias ;
Reichenspurner, Hermann ;
Pecha, Simon .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (08) :2101-2106
[46]   Transcatheter cardiac interventions in neonates with congenital heart disease: A single centre experience [J].
Melekoglu, Asli Nuriye ;
Baspinar, Osman .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (02) :615-625
[47]   Cardiologist-Directed Sedation Management in Patients Undergoing Transvenous Lead Extraction: A Single-Centre Retrospective Analysis [J].
Bock, Matthias ;
O'Connor, Matthew ;
Chouchane, Amir ;
Schmidt, Philip ;
Schaarschmidt, Claudia ;
Knoll, Katharina ;
Bahlke, Fabian ;
Englert, Florian ;
Storz, Theresa ;
Kottmaier, Marc ;
Trenkwalder, Teresa ;
Reents, Tilko ;
Bourier, Felix ;
Telishevska, Marta ;
Lengauer, Sarah ;
Hessling, Gabriele ;
Deisenhofer, Isabel ;
Kolb, Christof ;
Lennerz, Carsten .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (15)
[48]   The role of cardiac surgery in transvenous lead extraction. A high-volume center experience with 3207 procedures [J].
Tulecki, Lukasz ;
Czajkowski, Marek ;
Targonska, Sylwia ;
Tomkow, Konrad ;
Nowosielecka, Dorota ;
Jachec, Wojciech ;
Polewczyk, Anna ;
Kutarski, Andrzej .
KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA-POLISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 19 (03) :122-129
[49]   Cerebrovascular events complicating cardiac catheterization-A tertiary care cardiac centre experience [J].
Shivashankarappa, Arun B. ;
Mahadevappa, Nagesh C. ;
Palakshachar, Anand ;
Bhat, Prabhavathi ;
Barthur, Ashita ;
Bangalore, Sripal ;
Chikkaswamy, Srinivas B. ;
Katheria, Rockey ;
Nanjappa, Manjunath C. .
HEART VIEWS, 2021, 22 (04) :264-270
[50]   Feasibility of Continuous Monitoring of Endoscopy Performance and Adverse Events: A Single-Center Experience [J].
Zandanell, Stephan ;
Gensluckner, Sophie ;
Wolkersdoerfer, Gernot ;
Berr, Frieder ;
Dienhart, Christiane ;
Gantschnigg, Antonia ;
Singhartinger, Franz ;
Wagner, Andrej .
CANCERS, 2023, 15 (03)