Virtual monoenergetic images by spectral detector computed tomography may improve image quality and diagnostic ability for ischemic lesions in acute ischemic stroke

被引:3
|
作者
Mellander, Helena [1 ,2 ]
Bengtsson, Par [1 ,2 ]
Fransson, Veronica [3 ,4 ]
Ramgren, Birgitta [1 ,2 ]
Undren, Per [1 ,2 ]
Drake, Mattias [1 ,2 ]
Ydstrom, Kristina [2 ,3 ]
Latt, Jimmy [5 ]
Hilal, Amir [1 ,2 ]
Wasselius, Johan [1 ,2 ]
Ullberg, Teresa [1 ,2 ]
机构
[1] Skane Univ Hosp, Ctr Med Imaging & Physiol, Dept Neuroradiol & Odontol, Lund, Sweden
[2] Lund Univ, Dept Clin Sci, Lund, Sweden
[3] Lund Univ, Dept Translat Med, Med Radiat Phys, Malmo, Sweden
[4] Skane Univ Hosp, Dept Hematol Oncol & Radiat Phys, Radiat Phys, Lund, Sweden
[5] Skane Univ Hosp, Ctr Med Imaging & Physiol, Lund, Sweden
关键词
Dual-energy computed tomography; dual-layer computed tomography detector; monochromatic computed tomography images; image quality; ischemic stroke; DUAL-ENERGY CT; HEALTH-CARE PROFESSIONALS; ARTIFICIAL-INTELLIGENCE; PERFORMANCE EVALUATION; EARLY MANAGEMENT; NON-CONTRAST; BRAIN; RECONSTRUCTION; VISUALIZATION; GUIDELINES;
D O I
10.1177/02841851221130612
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Acute ischemic lesions are challenging to detect by conventional computed tomography (CT). Virtual monoenergetic images may improve detection rates by increased tissue contrast. Purpose To compare the ability to detect ischemic lesions of virtual monoenergetic with conventional images in patients with acute stroke. Material and Methods We included consecutive patients at our center that underwent brain CT in a spectral scanner for suspicion of acute stroke, onset <12 h, with or without (negative controls) a confirmed cortical ischemic lesion in the initial scan or a follow-up CT or magnetic resonance imaging. Attenuation was measured in predefined areas in ischemic gray (guided by follow-up exams), normal gray, and white matter in conventional images and retrieved in spectral diagrams for the same locations in monoenergetic series at 40-200 keV. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Visual assessment of diagnostic measures was performed by independent review by two neuroradiologists blinded to reconstruction details. Results In total, 29 patients were included (January 2018 to July 2019). SNR was higher in virtual monoenergetic compared to conventional images, significantly at 60-150 keV. CNR between ischemic gray and normal white matter was higher in monoenergetic images at 40-70 keV compared to conventional images. Virtual monoenergetic images received higher scores in overall image quality. The sensitivity for diagnosing acute ischemia was 93% and 97%, respectively, for the reviewers, compared to 55% of the original report based on conventional images. Conclusion Virtual monoenergetic reconstructions of spectral CIs may improve image quality and diagnostic ability in stroke assessment.
引用
收藏
页码:1631 / 1640
页数:10
相关论文
共 50 条
  • [1] Effect of Virtual Monoenergetic Images From Spectral Detector Computed Tomography on Coronary Calcium Blooming
    Van Hedent, Steven
    Hokamp, Nils Grosse
    Kessner, Rivka
    Gilkeson, Robert
    Ros, Pablo R.
    Gupta, Amit
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 912 - 918
  • [2] Texture analysis of computed tomography images of acute ischemic stroke patients
    Oliveira, M. S.
    Fernandes, P. T.
    Avelar, W. M.
    Santos, S. L. M.
    Castellano, G.
    Li, L. M.
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2009, 42 (11) : 1076 - 1079
  • [3] Automatic Detection and Segmentation of Ischemic Lesions in Computed Tomography Images of Stroke Patients
    Vos, Pieter C.
    Biesbroek, J. Matthijs
    Weaver, Nick A.
    Velthuis, Birgitta K.
    Viergever, Max A.
    MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670
  • [4] Ability of Emergency Physicians to Detect Early Ischemic Changes of Acute Ischemic Stroke on Cranial Computed Tomography
    Unluer, Erden Erol
    Yaka, Erdem
    Akhan, Galip
    Limon, Onder
    Kara, Pinar Hanife
    Yavasi, Ozcan
    Vandenberk, Nergiz
    Nazli, Yasemin Ece
    Kutluk, Kursad
    MEDICAL PRINCIPLES AND PRACTICE, 2012, 21 (06) : 534 - 537
  • [5] Virtual monoenergetic images from spectral detector computed tomography facilitate washout assessment in arterially hyper-enhancing liver lesions
    R. P. Reimer
    N. Große Hokamp
    A. Fehrmann Efferoth
    A. Krauskopf
    D. Zopfs
    J. R. Kröger
    T. Persigehl
    D. Maintz
    A. C. Bunck
    European Radiology, 2021, 31 : 3468 - 3477
  • [6] Virtual monoenergetic images from spectral detector computed tomography facilitate washout assessment in arterially hyper-enhancing liver lesions
    Reimer, R. P.
    Grosse Hokamp, N.
    Fehrmann Efferoth, A.
    Krauskopf, A.
    Zopfs, D.
    Kroeger, J. R.
    Persigehl, T.
    Maintz, D.
    Bunck, A. C.
    EUROPEAN RADIOLOGY, 2021, 31 (05) : 3468 - 3477
  • [7] Phantom Validation of Spectral Detector Computed Tomography-Derived Virtual Monoenergetic, Virtual Noncontrast, and Iodine Quantification Images
    Ananthakrishnan, Lakshmi
    Duan, Xinhui
    Rajiah, Prabhakar
    Soesbe, Todd C.
    Lewis, Matthew A.
    Xi, Yin
    Fielding, Julia R.
    Lenkinski, Robert E.
    Leyendecker, John R.
    Abbara, Suhny
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 959 - 964
  • [8] Assessment of Virtual Monoenergetic Images in Run-off Computed Tomography Angiography: A Comparison Study to Conventional Images From Spectral Detector Computed Tomography
    Ren, Haiyan
    Zhen, Yanhua
    Gong, Zheng
    Wang, Chuanzhuo
    Chang, Zhihui
    Zheng, Jiahe
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (02) : 232 - 237
  • [9] Utility of virtual monoenergetic images from spectral detector computed tomography in improving image segmentation for purposes of 3D printing and modeling
    Elias Kikano
    Nils Grosse Hokamp
    Leslie Ciancibello
    Nikhil Ramaiya
    Christos Kosmas
    Amit Gupta
    3D Printing in Medicine, 5
  • [10] Utility of virtual monoenergetic images from spectral detector computed tomography in improving image segmentation for purposes of 3D printing and modeling
    Kikano, Elias
    Hokamp, Nils Grosse
    Ciancibello, Leslie
    Ramaiya, Nikhil
    Kosmas, Christos
    Gupta, Amit
    3D PRINTING IN MEDICINE, 2019, 5 (01)