Determination of chlorophylls a and b and β-carotene in environmental waters: Diminishing wastes and analysis time by in-tube solid-phase microextraction coupled on-line to nano liquid chromatography

被引:3
作者
Soto, C. [1 ]
Herraez-Hernandez, R. [1 ]
Campins-Falco, P. [1 ]
机构
[1] Univ Valencia, Dept Quim Analit, MINTOTA Res Grp, Fac Quim, Dr Moliner 50, Burjassot 46100, Valencia, Spain
来源
ADVANCES IN SAMPLE PREPARATION | 2023年 / 8卷
关键词
Chlorophylls; Carotenoids; Water samples; In-tube solid phase microextraction; Nano liquid chromatography; Time; Low residues; Friendly solvent; IDENTIFICATION; PHYTOPLANKTON; EXTRACTION; TOOL;
D O I
10.1016/j.sampre.2023.100093
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chlorophylls and carotenoids are indicators of water quality. A new method based on in-tube solid-phase microextraction (IT-SPME) coupled on-line to nano-liquid chromatography with diode array detection (NanoLCDAD) was developed. This paper aims to provide selectivity and sensitivity with a short analysis time of about 10 min and low residues of friendly solvents, 5 mu L/run of ethanol:water 95:5 and 250 mu L of ethanol for dissolving the pigments retained in a nylon filter (0.45 mu m, 13 mm) from 30 mL of water. IT-SPME capillary was a fused silica capillary (10 cm length x 75 mu m internal diameter, i.d.) with a coating of tetraethyl orthosilicato (TEOS), triethoximethylsilane (MTEOS) doped with SiO2 nanoparticles (NPs) and an analytical column Zorbax 300SB-C18 (50 mm x 75 mu m i.d., 3.5 mu m particle size) was used. The recovery obtained to chlorophyll a, chlorophyll b and beta-carotene were 93 +/- 8 %, 92 +/- 7 % and 94 +/- 4 %, respectively. The method shows good linearity in the range up to 300 mu g L-1 for chlorophyll a and beta-carotene and up to 600 mu g L-1 for chlorophyll b. The achieved limits of detection (LODs) in samples were 0.1 mu g L-1 to chlorophyll a and beta-carotene, and 0.2 mu g L-1 to chlorophyll b. Values of relative standard deviations (RSD) expressed in% between 2 and 3 were obtained. Pigments were successfully determined with a short analysis time and minimal residues in real water samples.
引用
收藏
页数:7
相关论文
共 26 条
[21]   In tube-solid phase microextraction-nano liquid chromatography: Application to the determination of intact and degraded polar triazines in waters and recovered struvite [J].
Serra-Mora, P. ;
Jornet-Martinez, N. ;
Moliner-Martinez, Y. ;
Campins-Falco, P. .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1513 :51-58
[22]   Rapid and highly sensitive analysis of chlorophylls and carotenoids from marine phytoplankton using ultra-high performance liquid chromatography (UHPLC) with the first derivative spectrum chromatogram (FDSC) technique [J].
Suzuki, Koji ;
Kamimura, Akiko ;
Hooker, Stanford B. .
MARINE CHEMISTRY, 2015, 176 :96-109
[23]   Problems in extraction and spectrophotometric determination of chlorophyll from epilithic microbial biofilms: towards a standard method [J].
Thompson, RC ;
Tobin, ML ;
Hawkins, SJ ;
Norton, TA .
JOURNAL OF THE MARINE BIOLOGICAL ASSOCIATION OF THE UNITED KINGDOM, 1999, 79 (03) :551-558
[24]   An in-tube SPME device for the selective determination of chlorophyll a in aquatic systems [J].
Vitta, Y. ;
Moliner-Martinez, Y. ;
Campins-Falco, P. ;
Fernandez Cuervo, A. .
TALANTA, 2010, 82 (03) :952-956
[25]   Fruit tree leaves as unconventional and valuable source of chlorophyll and carotenoid compounds determined by liquid chromatography-photodiode-quadrupole/time of flight-electrospray ionization-mass spectrometry (LC-PDA-qTof-ESI-MS) [J].
Wojdylo, Aneta ;
Nowicka, Paulina ;
Tkacz, Karolina ;
Turkiewicz, Igor Piotr .
FOOD CHEMISTRY, 2021, 349 (349)
[26]   IMPROVED HPLC METHOD FOR THE ANALYSIS OF CHLOROPHYLLS AND CAROTENOIDS FROM MARINE-PHYTOPLANKTON [J].
WRIGHT, SW ;
JEFFREY, SW ;
MANTOURA, RFC ;
LLEWELLYN, CA ;
BJORNLAND, T ;
REPETA, D ;
WELSCHMEYER, N .
MARINE ECOLOGY PROGRESS SERIES, 1991, 77 (2-3) :183-196