Performance evaluation of a solar desalination-hot water system using heat pipe vacuum tube parabolic trough solar collector-An experimental study with Taguchi analysis

被引:57
作者
Omidi, Bagher [1 ]
Rahbar, Nader [2 ]
Kargarsharifabad, Hadi [2 ,3 ]
Moziraji, Zahra Poolaei [1 ]
机构
[1] Islamic Azad Univ, Dept Mech Engn, North Tehran Branch, Tehran, Iran
[2] Islamic Azad Univ, Energy & Sustainable Dev Res Ctr, Semnan Branch, Semnan, Iran
[3] Islamic Azad Univ, Prod & Recycling Mat & Energy Res Ctr, Qom Branch, Qom, Iran
关键词
Solar desalination; Parabolic trough solar collector; Heat pipe vacuum tube; Taguchi-method; Design of experiments; ECONOMIC-ANALYSIS; EVACUATED TUBE; ENERGY MATRICES; WORKING FLUID; STILL; OPTIMIZATION; ENHANCEMENT; EXERGY; BASIN; FLOW;
D O I
10.1016/j.enconman.2023.117347
中图分类号
O414.1 [热力学];
学科分类号
摘要
The utilization of renewable energy to generate hot water and distilled water can considerably reduce pollution. This study looked at a hybrid system that used a parabolic-trough heat pipe solar collector to generate hot water while also providing drinking water. The system is constructed in two stages, the first producing distilled water and the second producing hot water. A concave mirror increases the temperature of a vacuum tube heat pipe's evaporator area and the condenser of the heat pipe, which is directly connected to the desalination system's saltwater tank. To improve the amount of drinking water generated and to transfer thermal energy to the hot water generation system, a condenser region at the top of the saltwater tank, as well as multiple heat pipes, were employed. The effect of the water flow rate (200, 300, 400 and 500 ml/min), number of heat pipes (0, 1, 2 and 4), and the filling porous medium (0, 0.3, 0.6 and 0.9 m) of the vacuum tube on the system performance were evaluated. In addition, Taguchi-Based design of experiments was used to determine the effect of independent input parameters on the energy and efficiency of the system. The results showed that the effects of water flow rate, porous medium length, and number of heat pipes on the energy efficiency were approximately 50.89%, 26.53%, and 20.6%, respectively. Furthermore, the cost of distilled water and the cost of hot water were approximately 0.0380 $/L and 1.01 $/m3, respectively. Additionally, the highest daily productivity of the system (4940 ml/day) was obtained with a water flow rate of 200 ml/min, a length of porous media of 0.6 m, and four heat pipes. The CO2 emission reduction based on the environmental and enviroexergoeconomic parameters of the proposed systems ware improved by 37.5% and 268.4%, respectively, resulting in returns of approximately $358.1 and $260.5, respectively.
引用
收藏
页数:14
相关论文
共 50 条
[41]   Performance Analysis of a Solar Cascaded Absorption Cooling System Using a Performance-Enhanced Parabolic Trough Collector [J].
Altwijri, Faisal ;
Sherif, S. A. ;
Alghamdi, Abdulmajeed .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2023, 145 (06)
[42]   Heat Transfer Enhancement Analysis of Tube Receiver for Parabolic Trough Solar Collector With Central Corrugated Insert [J].
Benabderrahmane, Amina ;
Benazza, Abdelylah ;
Hussein, Ahmed Kadhim .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2020, 142 (06)
[43]   A novel solar desalination system based on an evacuated tube collective condenser heat pipe solar collector: A thermo-economic and environmental analysis [J].
Nema, Garima ;
Karunamurthy, K. .
FRONTIERS IN MECHANICAL ENGINEERING-SWITZERLAND, 2022, 8
[44]   Investigation of thermal performance of a parabolic trough solar collector using different heat transfer fluids [J].
Basha, Shaik Khadhar ;
Behura, Aruna Kumar .
ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (03) :7198-7221
[45]   Life cycle cost analysis of new FRP based solar parabolic trough collector hot water generation system [J].
A. Valan Arasu ;
T. Sornakumar .
Journal of Zhejiang University-SCIENCE A, 2008, 9 :416-422
[46]   Life cycle cost analysis of new FRP based solar parabolic trough collector hot water generation system [J].
Arasu, A. Valan ;
Sornakumar, T. .
JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2008, 9 (03) :416-422
[47]   Improving solar still performance with heat pipe/pulsating heat pipe evacuated tube solar collectors and PCM: An experimental and environmental analysis [J].
Hemmatian, Amir ;
Kargarsharifabad, Hadi ;
Esfahlani, Ahad Abedini ;
Rahbar, Nader ;
Shoeibi, Shahin .
SOLAR ENERGY, 2024, 269
[48]   Energetic and exergetic analysis of a heat pipe evacuated tube solar collector using MWCNT/water nanofluid [J].
Eltaweel, Mahmoud ;
Abdel-Rehim, Ahmed A. ;
Attia, Ahmed A. A. .
CASE STUDIES IN THERMAL ENGINEERING, 2020, 22
[49]   Thermal performance improvement using unilateral spiral ribbed absorber tube for parabolic trough solar collector [J].
Zou, Bin ;
Jiang, Yiqiang ;
Yao, Yang ;
Yang, Hongxing .
SOLAR ENERGY, 2019, 183 (371-385) :371-385
[50]   Performance analysis of a direct-absorption parabolic-trough solar collector using plasmonic nanofluids [J].
Qin, Caiyan ;
Kim, Joong Bae ;
Lee, Bong Jae .
RENEWABLE ENERGY, 2019, 143 :24-33