Performance evaluation of a solar desalination-hot water system using heat pipe vacuum tube parabolic trough solar collector-An experimental study with Taguchi analysis

被引:48
|
作者
Omidi, Bagher [1 ]
Rahbar, Nader [2 ]
Kargarsharifabad, Hadi [2 ,3 ]
Moziraji, Zahra Poolaei [1 ]
机构
[1] Islamic Azad Univ, Dept Mech Engn, North Tehran Branch, Tehran, Iran
[2] Islamic Azad Univ, Energy & Sustainable Dev Res Ctr, Semnan Branch, Semnan, Iran
[3] Islamic Azad Univ, Prod & Recycling Mat & Energy Res Ctr, Qom Branch, Qom, Iran
关键词
Solar desalination; Parabolic trough solar collector; Heat pipe vacuum tube; Taguchi-method; Design of experiments; ECONOMIC-ANALYSIS; EVACUATED TUBE; ENERGY MATRICES; WORKING FLUID; STILL; OPTIMIZATION; ENHANCEMENT; EXERGY; BASIN; FLOW;
D O I
10.1016/j.enconman.2023.117347
中图分类号
O414.1 [热力学];
学科分类号
摘要
The utilization of renewable energy to generate hot water and distilled water can considerably reduce pollution. This study looked at a hybrid system that used a parabolic-trough heat pipe solar collector to generate hot water while also providing drinking water. The system is constructed in two stages, the first producing distilled water and the second producing hot water. A concave mirror increases the temperature of a vacuum tube heat pipe's evaporator area and the condenser of the heat pipe, which is directly connected to the desalination system's saltwater tank. To improve the amount of drinking water generated and to transfer thermal energy to the hot water generation system, a condenser region at the top of the saltwater tank, as well as multiple heat pipes, were employed. The effect of the water flow rate (200, 300, 400 and 500 ml/min), number of heat pipes (0, 1, 2 and 4), and the filling porous medium (0, 0.3, 0.6 and 0.9 m) of the vacuum tube on the system performance were evaluated. In addition, Taguchi-Based design of experiments was used to determine the effect of independent input parameters on the energy and efficiency of the system. The results showed that the effects of water flow rate, porous medium length, and number of heat pipes on the energy efficiency were approximately 50.89%, 26.53%, and 20.6%, respectively. Furthermore, the cost of distilled water and the cost of hot water were approximately 0.0380 $/L and 1.01 $/m3, respectively. Additionally, the highest daily productivity of the system (4940 ml/day) was obtained with a water flow rate of 200 ml/min, a length of porous media of 0.6 m, and four heat pipes. The CO2 emission reduction based on the environmental and enviroexergoeconomic parameters of the proposed systems ware improved by 37.5% and 268.4%, respectively, resulting in returns of approximately $358.1 and $260.5, respectively.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] An active solar desalination system integrated with collective condenser heat pipe solar evacuated tube collector: a thermoeconomic analysis
    Nema, Garima
    Krishnasamy, Karunamurthy
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2024, 31 (07) : 10273 - 10295
  • [2] A new desalination system using a combination of heat pipe, evacuated tube and parabolic trough collector
    Mosleh, H. Jafari
    Mamouri, S. Jahangiri
    Shafii, M. B.
    Sima, A. Hakim
    ENERGY CONVERSION AND MANAGEMENT, 2015, 99 : 141 - 150
  • [3] Performance Evaluation of Novel Heat Pipe-Assisted Thermal Storage System with Parabolic Trough Solar Collector Using Nanofluid
    Kalbande, Vednath P.
    Walke, Pramod, V
    Untawale, Sachin
    Mohan, Man
    ENERGY TECHNOLOGY, 2022, 10 (09)
  • [4] Thermal performance analysis of a parabolic trough collector based solar water heater using revolving absorber tube
    Naveenkumar, Rasaiah
    Singh, Pradeep Kumar
    Ravichandran, Manickam
    Mohanavel, Vinayagam
    Venkateshkumar, Rajaraman
    Kedia, Ankit
    Kannan, Sathish
    Soudagar, Manzoore Elahi M.
    RESULTS IN ENGINEERING, 2025, 25
  • [5] Experimental study of a parabolic trough solar collector with rotating absorber tube
    Norouzi, Amir Mohammad
    Siavashi, Majid
    Ahmadi, Rouhollah
    Tahmasbi, Milad
    RENEWABLE ENERGY, 2021, 168 : 734 - 749
  • [6] Experimental Study of a Tubular Solar Distillation System with Heat Exchanger Using a Parabolic Trough Collector
    Amin, Muhammad
    Umar, Hamdani
    Amir, Fazri
    Ginting, Suma Fachruri
    Sudarsana, Putu Brahmanda
    Septiadi, Wayan Nata
    SUSTAINABILITY, 2022, 14 (21)
  • [7] In situ latent thermal energy storage in underfloor heating system of building connected to the parabolic trough solar collector-an experimental study
    Malekpour, Ali
    Ahmadi, Rouhollah
    Sadeghzadeh, Sadegh
    JOURNAL OF ENERGY STORAGE, 2021, 44
  • [8] Theoretical and experimental analysis of thermal performance of a solar water heating system with evacuated tube heat pipe collector
    Daghigh, Roonak
    Shafieian, Abdellah
    APPLIED THERMAL ENGINEERING, 2016, 103 : 1219 - 1227
  • [9] An active solar desalination system integrated with collective condenser heat pipe solar evacuated tube collector: a thermoeconomic analysis
    Garima Nema
    Karunamurthy Krishnasamy
    Environmental Science and Pollution Research, 2024, 31 : 10273 - 10295
  • [10] Computational comparison and experimental performance analysis on heat pipes using concentrating solar parabolic trough collector
    Kumar, P. Ravindra
    Babu, Nelakuditi N.
    Prasad, K. Lakshmi
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2022, 236 (05) : 875 - 892