Clinically feasible B1 field correction for multi-organ sodium imaging at 3 T

被引:4
作者
Vaeggemose, Michael [1 ,2 ]
Schulte, Rolf F. [3 ]
Laustsen, Christoffer [2 ]
机构
[1] GE Healthcare, DK-2605 Brondby, Denmark
[2] Aarhus Univ, MR Res Ctr, Dept Clin Med, Aarhus, Denmark
[3] GE Healthcare, Munich, Germany
关键词
B-1 field correction; clinically feasible protocol; multi-organ; sodium imaging; MAGNETIC-RESONANCE; NA-23; MRI; COILS; QUANTIFICATION; EXERCISE; PROTOCOL; BRAIN; TIME;
D O I
10.1002/nbm.4835
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Sodium MRI allows the non-invasive quantification of intra-organ sodium concentration. RF inhomogeneity introduces uncertainty in this estimated concentration. B-1 field corrections can be used to overcome some of these limitations. However, the low signal-to-noise ratio in sodium MRI makes accurate B-1 mapping in reasonable scan times challenging. The study aims to evaluate Bloch-Siegert off-resonance (BLOSI) B-1 field correction for sodium MRI using a 3D Fermat looped, orthogonally encoded trajectories (FLORET) read-out trajectory. We propose a clinically feasible B-1 field map correction method for sodium imaging at 3 T, evaluating five healthy subjects' brain, heart blood, kidneys, and thigh muscle. We scanned the subjects twice for repeatability measures and used sodium phantoms to determine organ total sodium concentration. Conventional proton scans were compared with sodium images for organ structural integrity. The BLOSI approach based on the 3D FLORET read-out trajectory was used in B-1 field correction and 3D density-adapted radial acquisition for sodium imaging. Results indicate improvements in sodium imaging based on B-1 field correction in a clinically feasible protocol. Improvements are determined in all organs by enhanced anatomical representation, organ homogeneity, and an increase in the total sodium concentration after applying a B-1 field correction. The proposed BLOSI-based B-1 field correction using a 3D FLORET read-out trajectory is clinically feasible for sodium imaging, which is shown in the brain, heart, kidney, and thigh muscle. This supports using fast B-1 field mapping in the clinical setting.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Frequency Offset Corrected Inversion Pulse for B0 and B1 Insensitive Fat Suppression at 3T: Application to MR Neurography of Brachial Plexus
    Wang, Xinzeng
    Greer, Joshua S.
    Dimitrov, Ivan E.
    Pezeshk, Parham
    Chhabra, Avneesh
    Madhuranthakam, Ananth J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (04) : 1104 - 1111
  • [42] Variable Flip Angle-Based Fast Three-Dimensional T1 Mapping for Delayed Gadolinium-Enhanced MRI of Cartilage of the Knee: Need for B1 Correction
    Manuel, Angela
    Li, Wei
    Jellus, Vladimir
    Hughes, Timothy
    Prasad, Pottumarthi V.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) : 1377 - 1383
  • [43] Spatially resolved free-induction decay spectroscopy using a 3D ultra-short echo time multi-echo imaging sequence with systematic echo shifting and compensation of B0 field drifts
    Fischer, Anja
    Martirosian, Petros
    Benkert, Thomas
    Schick, Fritz
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) : 2099 - 2110
  • [44] Reduction of B1 Sensitivity in Selective Single-Slab 3D Turbo Spin Echo Imaging with Very Long Echo Trains
    Park, Jaeseok
    Mugler, John P., III
    Hughes, Timothy
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) : 1060 - 1066
  • [45] Transmit B1+ Field Inhomogeneity and T1 Estimation Errors in Breast DCE-MRI at 3 Tesla
    Sung, Kyunghyun
    Daniel, Bruce L.
    Hargreaves, Brian A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (02) : 454 - 459
  • [46] Accelerated 3D multi-channel B1+ mapping at 7 T for the brain and heart
    Kent, James L.
    de Buck, Matthijs H. S.
    Dragonu, Iulius
    Chiew, Mark
    Valkovic, Ladislav
    Hess, Aaron T.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (05) : 2007 - 2020
  • [47] Three-Dimensional Mapping of the B1 Field Using an Optimized Phase-Based Method: Application to Hyperpolarized 3He in Lungs
    Santoro, Davide
    Rivoire, Julien
    Meise, Florian
    Terekhov, Maxim
    Salhi, Zahir
    Gast, Klaus
    Schreiber, Laura M.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 1166 - 1172
  • [48] Optimized navigator-based correction of breathing-induced B0 field fluctuations in multi-echo gradient-echo imaging of the spinal cord
    Beghini, Laura
    Bueler, Silvan
    Liechti, Martina D.
    Jaffray, Alexander
    David, Gergely
    Vannesjo, S. Johanna
    MAGNETIC RESONANCE IN MEDICINE, 2025, : 215 - 230
  • [49] Apparent Diffusion Coefficient and Sodium Concentration Measurements in Human Prostate Tissue via Hydrogen-1 and Sodium-23 Magnetic Resonance Imaging in a Clinical Setting at 3 T
    Hausmann, Daniel
    Konstandin, Simon
    Wetterling, Friedrich
    Haneder, Stefan
    Nagel, Armin M.
    Dinter, Dietmar J.
    Schoenberg, Stefan O.
    Zoellner, Frank G.
    Schad, Lothar R.
    INVESTIGATIVE RADIOLOGY, 2012, 47 (12) : 677 - 682
  • [50] Optimization of Look-Locker Turbo-Field Echo-Planar Imaging and Evaluation of Its Accuracy in Head and Neck 3D T1 Mapping
    Maehara, Masanori
    Monma, Masahiko
    Nitanai, Takeshi
    Matsumoto, Tetsuya
    Fukuma, Yukiko
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (03) : 288 - 298