Clinically feasible B1 field correction for multi-organ sodium imaging at 3 T

被引:4
作者
Vaeggemose, Michael [1 ,2 ]
Schulte, Rolf F. [3 ]
Laustsen, Christoffer [2 ]
机构
[1] GE Healthcare, DK-2605 Brondby, Denmark
[2] Aarhus Univ, MR Res Ctr, Dept Clin Med, Aarhus, Denmark
[3] GE Healthcare, Munich, Germany
关键词
B-1 field correction; clinically feasible protocol; multi-organ; sodium imaging; MAGNETIC-RESONANCE; NA-23; MRI; COILS; QUANTIFICATION; EXERCISE; PROTOCOL; BRAIN; TIME;
D O I
10.1002/nbm.4835
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Sodium MRI allows the non-invasive quantification of intra-organ sodium concentration. RF inhomogeneity introduces uncertainty in this estimated concentration. B-1 field corrections can be used to overcome some of these limitations. However, the low signal-to-noise ratio in sodium MRI makes accurate B-1 mapping in reasonable scan times challenging. The study aims to evaluate Bloch-Siegert off-resonance (BLOSI) B-1 field correction for sodium MRI using a 3D Fermat looped, orthogonally encoded trajectories (FLORET) read-out trajectory. We propose a clinically feasible B-1 field map correction method for sodium imaging at 3 T, evaluating five healthy subjects' brain, heart blood, kidneys, and thigh muscle. We scanned the subjects twice for repeatability measures and used sodium phantoms to determine organ total sodium concentration. Conventional proton scans were compared with sodium images for organ structural integrity. The BLOSI approach based on the 3D FLORET read-out trajectory was used in B-1 field correction and 3D density-adapted radial acquisition for sodium imaging. Results indicate improvements in sodium imaging based on B-1 field correction in a clinically feasible protocol. Improvements are determined in all organs by enhanced anatomical representation, organ homogeneity, and an increase in the total sodium concentration after applying a B-1 field correction. The proposed BLOSI-based B-1 field correction using a 3D FLORET read-out trajectory is clinically feasible for sodium imaging, which is shown in the brain, heart, kidney, and thigh muscle. This supports using fast B-1 field mapping in the clinical setting.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] On B1 inhomogeneity correction of in vivo human brain glutamate chemical exchange saturation transfer contrast at 7T
    Singh, Anup
    Cai, Kejia
    Haris, Mohammad
    Hariharan, Hari
    Reddy, Ravinder
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) : 818 - 824
  • [32] Correction of B1-inhomogeneities for relaxation-compensated CEST imaging at 7T
    Windschuh, Johannes
    Zaiss, Moritz
    Meissner, Jan-Eric
    Paech, Daniel
    Radbruch, Alexander
    Ladd, Mark E.
    Bachert, Peter
    NMR IN BIOMEDICINE, 2015, 28 (05) : 529 - 537
  • [33] ANALYTICAL METHOD OF CORRECTION OF B1 ERRORS IN MAPPING OF MAGNETIZATION TRANSFER RATIO IN HIGH-FIELD MAGNETIC RESONANCE TOMOGRAPHY
    Yarnykh, V. L.
    Khodanovich, M. Yu.
    RUSSIAN PHYSICS JOURNAL, 2015, 57 (12) : 1784 - 1788
  • [34] A novel method for simultaneous 3D B1 and T1 mapping: the method of slopes (MoS)
    Chavez, Sofia
    Stanisz, Greg J.
    NMR IN BIOMEDICINE, 2012, 25 (09) : 1043 - 1055
  • [35] Investigation of the B1 field distribution and RF power deposition in a birdcage coil as functions of the number of coil legs at 4.7 T, 7.0 T, and 11.7 T
    Seo, Jeung-Hoon
    Han, Sang-Doc
    Kim, Kyoung-Nam
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (12) : 1822 - 1826
  • [36] B1 and magnetization decay correction for hyperpolarized 129Xe lung imaging using sequential 2D spiral acquisitions
    Bdaiwi, Abdullah S.
    Costa, Mariah L.
    Plummer, Joseph W.
    Willmering, Matthew M.
    Walkup, Laura L.
    Cleveland, Zackary I.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (02) : 473 - 482
  • [37] B1 Transmission-Field Inhomogeneity and Enhancement Ratio Errors in Dynamic Contrast-Enhanced MRI (DCE-MRI) of the Breast at 3T
    Azlan, Che A.
    Di Giovanni, Pierluigi
    Ahearn, Trevor S.
    Semple, Scott I. K.
    Gilbert, Fiona J.
    Redpath, Thomas W.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) : 234 - 239
  • [38] Spiral 3-Dimensional T1-Weighted Turbo Field Echo: Increased Speed for Magnetization-Prepared Gradient Echo Brain Magnetic Resonance Imaging
    Sartoretti, Thomas
    Sartoretti, Elisabeth
    van Smoorenburg, Luuk
    Schwenk, Arpad
    Mannil, Manoj
    Graf, Nicole
    Binkert, Christoph A.
    Wyss, Michael
    Sartoretti-Schefer, Sabine
    INVESTIGATIVE RADIOLOGY, 2020, 55 (12) : 775 - 784
  • [39] Complex B1 mapping and electrical properties imaging of the human brain using a 16-channel transceiver coil at 7T
    Zhang, Xiaotong
    Van de Moortele, Pierre-Francois
    Schmitter, Sebastian
    He, Bin
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) : 1285 - 1296
  • [40] Improving B1+homogeneity in abdominal imaging at 3 T with light, flexible, and compact metasurface
    Vorobyev, Vsevolod
    Shchelokova, Alena
    Efimtcev, Alexander
    Baena, Juan D.
    Abdeddaim, Redha
    Belov, Pavel
    Melchakova, Irina
    Glybovski, Stanislav
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (01) : 496 - 508