Clinically feasible B1 field correction for multi-organ sodium imaging at 3 T

被引:4
|
作者
Vaeggemose, Michael [1 ,2 ]
Schulte, Rolf F. [3 ]
Laustsen, Christoffer [2 ]
机构
[1] GE Healthcare, DK-2605 Brondby, Denmark
[2] Aarhus Univ, MR Res Ctr, Dept Clin Med, Aarhus, Denmark
[3] GE Healthcare, Munich, Germany
关键词
B-1 field correction; clinically feasible protocol; multi-organ; sodium imaging; MAGNETIC-RESONANCE; NA-23; MRI; COILS; QUANTIFICATION; EXERCISE; PROTOCOL; BRAIN; TIME;
D O I
10.1002/nbm.4835
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Sodium MRI allows the non-invasive quantification of intra-organ sodium concentration. RF inhomogeneity introduces uncertainty in this estimated concentration. B-1 field corrections can be used to overcome some of these limitations. However, the low signal-to-noise ratio in sodium MRI makes accurate B-1 mapping in reasonable scan times challenging. The study aims to evaluate Bloch-Siegert off-resonance (BLOSI) B-1 field correction for sodium MRI using a 3D Fermat looped, orthogonally encoded trajectories (FLORET) read-out trajectory. We propose a clinically feasible B-1 field map correction method for sodium imaging at 3 T, evaluating five healthy subjects' brain, heart blood, kidneys, and thigh muscle. We scanned the subjects twice for repeatability measures and used sodium phantoms to determine organ total sodium concentration. Conventional proton scans were compared with sodium images for organ structural integrity. The BLOSI approach based on the 3D FLORET read-out trajectory was used in B-1 field correction and 3D density-adapted radial acquisition for sodium imaging. Results indicate improvements in sodium imaging based on B-1 field correction in a clinically feasible protocol. Improvements are determined in all organs by enhanced anatomical representation, organ homogeneity, and an increase in the total sodium concentration after applying a B-1 field correction. The proposed BLOSI-based B-1 field correction using a 3D FLORET read-out trajectory is clinically feasible for sodium imaging, which is shown in the brain, heart, kidney, and thigh muscle. This supports using fast B-1 field mapping in the clinical setting.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Robust and Fast Whole Brain Mapping of the RF Transmit Field B1 at 7T
    Lutti, Antoine
    Stadler, Joerg
    Josephs, Oliver
    Windischberger, Christian
    Speck, Oliver
    Bernarding, Johannes
    Hutton, Chloe
    Weiskopf, Nikolaus
    PLOS ONE, 2012, 7 (03):
  • [22] Iterative multi-channel radio frequency pulse calibration with improving B1 field uniformity in high field MRI
    Hernandez, Daniel
    Cho, Min Hyoung
    Lee, Soo Yeol
    BIOMEDICAL ENGINEERING ONLINE, 2015, 14
  • [23] Iterative multi-channel radio frequency pulse calibration with improving B1 field uniformity in high field MRI
    Daniel Hernandez
    Min Hyoung Cho
    Soo Yeol Lee
    BioMedical Engineering OnLine, 14
  • [24] Intraoral Approach for Imaging Teeth Using the Transverse B1 Field Components of an Occlusally Oriented Loop Coil
    Idiyatullin, Djaudat
    Corum, Curtis A.
    Nixdorf, Donald R.
    Garwood, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (01) : 160 - 165
  • [25] Simultaneous mapping of water shift and B1(WASABI)Application to field-Inhomogeneity correction of CEST MRI data
    Schuenke, Patrick
    Windschuh, Johannes
    Roeloffs, Volkert
    Ladd, Mark E.
    Bachert, Peter
    Zaiss, Moritz
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 571 - 580
  • [26] Data-Driven Retrospective Correction of B1 Field Inhomogeneity in Fast Macromolecular Proton Fraction and R1 Mapping
    Yarnykh, Vasily L.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (12) : 3473 - 3484
  • [27] Alternating Look-Locker for quantitative T1, T1? and B1 3D MRI mapping
    Wu, Lin
    Carchi, Chris
    Michaeli, Shalom
    Mangia, Silvia
    Idiyatullin, Djaudat
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (01) : 149 - 161
  • [28] Fast B1 Mapping Based on Double-Angle Method with T1 Correction Using Standard Pulse Sequence
    Ishimori, Yoshiyuki
    Shimanuki, Takeshi
    Kobayashi, Tomoya
    Monma, Masahiko
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (01) : 93 - 98
  • [29] Evaluation of a Subject specific dual-transmit approach for improving B1 field homogeneity in cardiovascular magnetic resonance at 3T
    Krishnamurthy, Ramkumar
    Pednekar, Amol
    Kouwenhoven, Marc
    Cheong, Benjamin
    Muthupillai, Raja
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [30] Acquisition of 3He ventilation images, ADC, T2*and B1 maps in a single scan with compressed sensing
    Ajraoui, S.
    Parra-Robles, J.
    Marshall, H.
    Deppe, M. H.
    Clemence, M.
    Wild, J. M.
    NMR IN BIOMEDICINE, 2012, 25 (01) : 44 - 51