Radial head replacement with the 3D-printed patient-specific titanium prosthesis: Preliminary results of a multi-centric prospective study

被引:1
作者
Luenam, Suriya [1 ,2 ,5 ]
Kosiyatrakul, Arkaphat [1 ,2 ]
Charoenlap, Chris [3 ]
Puncreobutr, Chedtha [4 ]
Lohwongwatana, Boonrat [4 ]
机构
[1] Phramongkutklao Hosp, Dept Orthopaed, Bangkok, Thailand
[2] Chulalongkorn Univ, Dept Orthopaed, Bangkok, Thailand
[3] Chulalongkorn Univ, Fac Med, Dept Orthopaed, Bangkok, Thailand
[4] Chulalongkorn Univ, Fac Engn, Dept Met Engn, Bangkok, Thailand
[5] Phramongkutklao Hosp, Dept Orthopaed, 315 Ratchawithi Rd, Bangkok 10400, Thailand
关键词
3D-printed; patient-specific; prosthesis; radial head; ARTHROPLASTY; FRACTURES; DESIGN;
D O I
10.1177/10225536241236806
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTo report preliminary clinical results and safety of 3D-printed patient-specific titanium radial head (RH) prosthesis in treatment of the irreparable RH fractures.Material and methodsThis multi-centric prospective study included 10 patients (6 men and four women, mean age 41 years (range, 25-64 years)). Three cases were classified as Mason type III and 7 cases as type IV. Patients were assessed preoperatively, intraoperatively, and at 1, 6, 12, 24, 36, and 48 weeks postoperatively. Range of motion (ROM), visual analog scale (VAS) score, Disabilities of the Arm, Shoulder and Hand (DASH) score, Mayo Elbow Performance Score (MEPS), radiology imaging, and laboratory blood and urine testing were evaluated.ResultsThe prostheses were implanted utilizing cemented stems in 5 patients and cementless stems in 5 patients. Intraoperatively, well congruency of a prosthesis with capitellum and radial notch of ulna was observed in all cases. All patients had improvement of ROM, VAS score, DASH score, and MEPS during the postoperative follow-ups. At the final follow-up, mean elbow extension was 6.5 degrees (range, 0 degrees-30 degrees), flexion 145 degrees (range, 125 degrees-150 degrees), supination 79 degrees (range, 70 degrees-80 degrees), and pronation 73.5 degrees (range, 45 degrees-80 degrees). Mean VAS score was 0.3 (range, 0-3), DASH score was 12.35 (range, 1.7-23.3), and MEPS was 99.5 (range, 95-100). Postoperative radiographs demonstrated heterotopic ossification in 2 cases, periprosthetic radiolucency in 2 cases, and proximal radial neck resorption in 2 cases. No one had the evidence of capitellar erosion, implant failure, malpositioning, overstuffing, or symptomatic stem loosening. There was no significant alteration of laboratory results or adverse events related to the 3D-printed prosthesis implantation.ConclusionThe preliminary results demonstrated that implantation of the 3D-printed patient-specific titanium RH prosthesis is safe and may be a potential treatment option for irreparable RH fracture.
引用
收藏
页数:14
相关论文
共 45 条
  • [1] The effect of radial head excision and arthroplasty on elbow kinematics and stability
    Beingessner, DM
    Dunning, CE
    Gordon, KD
    Johnson, JA
    King, GJW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (08) : 1730 - 1739
  • [2] Clinical and radiographic comparisons of two different radial head implant designs
    Berschback, John C.
    Lynch, T. Sean
    Kalainov, David M.
    Wysocki, Robert W.
    Merk, Bradley R.
    Cohen, Mark S.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (08) : 1108 - 1120
  • [3] Radial head replacement in adults with recent fractures
    Bonnevialle, N.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (01) : S69 - S79
  • [4] The clinical implications of heterotopic ossification in patients treated with radial head replacement for trauma: A case series and review of the literature
    Bowman, Seth H.
    Barfield, William R.
    Slone, Harris S.
    Shealy, Gerald J.
    Walton, Zeke J.
    [J]. JOURNAL OF ORTHOPAEDICS, 2016, 13 (04) : 272 - 277
  • [5] Radial head arthroplasty
    Calfee, R
    Madom, I
    Weiss, APC
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (02): : 314 - 321
  • [6] Replacement or repair of terrible triad of the elbow: A systematic review and meta-analysis
    Chen, Hongwei
    Shao, Yinchu
    Li, Shaobo
    [J]. MEDICINE, 2019, 98 (06)
  • [7] Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability
    Doornberg, Job N.
    Parisien, Robert
    van Duijn, P. Joppe
    Ring, David
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (05) : 1075 - 1080
  • [8] Short- to mid-term results of metallic press-fit radial head arthroplasty in unstable injuries of the elbow
    Flinkkila, T.
    Kaisto, T.
    Sirnio, K.
    Hyvonen, P.
    Leppilahti, J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (06): : 805 - 810
  • [9] Outcomes Following Radial Head Arthroplasty
    Fowler, John R.
    Henry, Sarah E.
    Xu, Peter
    Goitz, Robert J.
    [J]. ORTHOPEDICS, 2016, 39 (03) : 153 - 160
  • [10] Critical time period for recovery of functional range of motion after surgical treatment of complex elbow instability: Prospective study on 76 patients
    Giannicola, Giuseppe
    Polimanti, David
    Bullitta, Gianluca
    Sacchetti, Federico M.
    Cinotti, Gianluca
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (03): : 540 - 545