Analytical solution for contaminant transport through a GCL-enhanced composite cutoff wall system

被引:7
|
作者
Liu, Jun [1 ,6 ,7 ,8 ]
Chen, Zhang-Long [2 ]
Yu, Chuang [1 ,6 ]
Wang, Shun [3 ]
Wu, Wei [4 ]
Xie, Shi-Ping [5 ]
机构
[1] Wenzhou Univ, Coll Civil Engn & Architecture, Wenzhou 325035, Peoples R China
[2] Tsinghua Univ, Dept Hydraul Engn, State Key Lab Hydrosci & Engn, Beijing 100084, Peoples R China
[3] Wuhan Univ, Inst Engn Risk & Disaster Prevent, State Key Lab Water Resources & Hydropower Engn Sc, 299 Bayi Rd, Wuhan 430072, Peoples R China
[4] Univ Bodenkultur, Inst Geotech, Feistmantelstr 4, A-1180 Vienna, Austria
[5] Tianjin Zhonglian Gelin Sci & Technol Dev Co Ltd, Tianjin 300387, Peoples R China
[6] Key Lab Engn & Technol Soft Soil Fdn & Tideland Re, Wenzhou 325035, Peoples R China
[7] Zhejiang Engn Res Ctr Disaster Prevent & Mitigat C, Wenzhou 325035, Zhejiang, Peoples R China
[8] Zhejiang Int Sci & Technol Cooperat Base Ultrasoft, Wenzhou 325035, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Cutoff wall; Geosynthetic clay liners; Analytical solution; Advection-dispersion-degradation; Aquifer; GEOSYNTHETIC CLAY LINERS; DIFFUSION; SORPTION;
D O I
10.1016/j.compgeo.2023.105828
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The geosynthetic clay liners (GCLs) have been recently shown to be effective in cutoff wall applications. Yet, its influence on contaminant transport through cutoff wall system is rarely reported. This study presents an analytical solution for the transport of organic contaminant through a composite cutoff wall system comprising a soil-bentonite wall, a GCL, and an aquifer. The analytical solution was obtained by variable separation method and verified against an existing analytical solution and a numerical solution. Parametric analysis was conducted to elucidate the effects of GCL, soil-bentonite (SB) wall thickness (Lw), aquifer thickness (La), and contaminant half-life (t1/2) on contaminant transport. The results show that by adding a GCL layer, the contaminant concentration and the maximum flux can be significantly decreased. When the GCL retardation factor increases 1 to 300, the required time to reach the maximum flux is delayed from about 62 years to 1500 years. Larger aquifer thickness sufficiently weakens the contaminant transport process. Under the same breakthrough criteria, the required thickness of SB wall decreases by about 20% when the GCL retardation factor increases from 1 to 50. The proposed analytical solution provides a useful tool for the design of the SB-GCL cutoff wall system.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Complex solution to nonideal contaminant transport through porous media
    Gambolati, G
    Pini, G
    JOURNAL OF COMPUTATIONAL PHYSICS, 1998, 145 (02) : 538 - 554
  • [42] An analytical model for one-dimensional diffusion of degradable contaminant through a composite geomembrane cut-off wall
    Peng, Chun-Hui
    Feng, Shi-Jin
    Chen, Hong-Xin
    Ding, Xiang-Hong
    Yang, Chun-Bai-Xue
    JOURNAL OF CONTAMINANT HYDROLOGY, 2021, 242
  • [44] Analytical modeling of contaminant transport through vadose and saturated soil zones
    Prakash, A
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 2000, 126 (10): : 773 - 777
  • [45] Analytical solution of contaminant diffusion through multi-layered soils
    Chen, Yun-Min
    Xie, Hai-Jian
    Ke, Han
    Tang, Xiao-Wu
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2006, 28 (04): : 521 - 524
  • [46] Analytical Model for Contaminant Transport in Composite Liners Considering the Longevity of Barrier Components
    Xie, Haijian
    Cai, Peifu
    Yan, Huaxiang
    Ding, Hao
    Li, Congcong
    WATER AIR AND SOIL POLLUTION, 2025, 236 (01):
  • [47] The effect of variability in hydraulic conductivity on contaminant transport through soil-bentonite cutoff walls
    Britton, JP
    Filz, GM
    Little, JC
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2005, 131 (08) : 951 - 957
  • [48] CONTAMINANT TRANSPORT IN FRACTURED POROUS-MEDIA - ANALYTICAL SOLUTION FOR A SINGLE FRACTURE
    TANG, DH
    FRIND, EO
    SUDICKY, EA
    WATER RESOURCES RESEARCH, 1981, 17 (03) : 555 - 564
  • [49] An analytical solution for two-dimensional contaminant transport during groundwater extraction
    Tartakovsky, DM
    JOURNAL OF CONTAMINANT HYDROLOGY, 2000, 42 (2-4) : 273 - 283
  • [50] Assessment of Consolidation-Induced VOC Transport for a GML/GCL Composite Liner System
    Pu, Hefu
    Shackelford, Charles D.
    Fox, Patrick J.
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2016, 142 (11)