Camera Wavelength Selection for Multi-wavelength Pulse Transit Time based Blood Pressure Monitoring

被引:6
|
作者
Huang, Yukai [1 ,2 ]
Huang, Dongmin [1 ]
Huang, Jia [4 ]
Lu, Hongzhou [4 ]
He, Min [2 ,3 ]
Wang, Wenjin [1 ]
机构
[1] Southern Univ Sci & Technol, Dept Biomed Engn, Shenzhen, Peoples R China
[2] Chinese Acad Sci, Hangzhou Inst Med HIM, Hangzhou 310022, Zhejiang, Peoples R China
[3] Zhejiang Canc Hosp, Key Lab Head Neck Canc Translat Res Zhejiang Prov, Hangzhou, Peoples R China
[4] Third Peoples Hosp Shenzhen, Intens Care Unit, Shenzhen, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Blood pressure; camera photoplethysmography; multi-wavelength; pulse transmit time;
D O I
10.1109/EMBC40787.2023.10340068
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Multi-wavelength pulse transmit time (MV-PTT) is a potential tool for remote blood pressure (BP) monitoring. It uses two wavelengths, typically green (G) and near-infrared (NIR), that have different skin penetration depths to measure the PTT between artery and arterioles of a single site of the skin for BP estimation. However, the impact of wavelength selection for MV-PTT based BP calibration is unknown. In this paper, we explore the combination of different wavelengths of camera photoplethysmography for BP measurement using a modified narrow-band camera centered at G-550/R-660/NIR-850 nm, especially focused on the comparison between G-R (full visible) and G-NIR (hybrid). The experiment was conducted on 17 adult participants in a dark chamber with their BP significantly changed by the protocol of ice water stimulation. The experimental results show that the MV-PTT obtained by G-NIR has a higher correlation with BP, and the fitted model has lower MAE in both the systolic pressure (5.78 mmHg) and diastolic pressure (6.67 mmHg) than others. It is confirmed that a hybrid wavelength of visible (G) and NIR is still essential for accurate BP calibration due to their difference in skin penetration depth that allows proper sensing of different skin layers for this measurement.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Multi-Wavelength Based Optical Density Sensor for Autonomous Monitoring of Microalgae
    Jia, Fei
    Kacira, Murat
    Ogden, Kimberly L.
    SENSORS, 2015, 15 (09) : 22234 - 22248
  • [22] Comparison of methods for wavelength combination selection from multi-wavelength fluorescence spectra for on-line monitoring of yeast cultivations
    Supasuda Assawajaruwan
    Jasmin Reinalter
    Bernd Hitzmann
    Analytical and Bioanalytical Chemistry, 2017, 409 : 707 - 717
  • [23] Comparison of methods for wavelength combination selection from multi-wavelength fluorescence spectra for on-line monitoring of yeast cultivations
    Assawajaruwan, Supasuda
    Reinalter, Jasmin
    Hitzmann, Bernd
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (03) : 707 - 717
  • [24] A Camera-Based Pulse Transit Time Estimation Approach Towards Non-Intrusive Blood Pressure Monitoring
    Patil, Omkar R.
    Wang, Wei
    Gao, Yang
    Jin, Zhanpeng
    2019 IEEE INTERNATIONAL CONFERENCE ON HEALTHCARE INFORMATICS (ICHI), 2019, : 257 - 266
  • [25] Single Camera System for Multi-wavelength Fruorescent Imaging in the Heart
    Yamanaka, Takeshi
    Arafune, Tatsuhiko
    Shibata, Nitaro
    Honjo, Haruo
    Kamiya, Kaichiro
    Kodama, Itsuo
    Sakuma, Ichiro
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3716 - 3719
  • [26] A Multi-wavelength Photoplethysmography System for Sleep Quality Monitoring
    Nabavi, Seyeclfakhreddin
    Cogan, John
    Roy, Asim
    Canfield, Brandon
    Kibler, Robert
    Emerick, Collin
    2023 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS, ICCE, 2023,
  • [27] Multi-wavelength monitoring of GRS1915+105
    Bandyopadhyay, R
    Martini, P
    Gerard, E
    Charles, PA
    Wagner, RM
    Shrader, C
    Shahbaz, T
    Mirabel, IF
    PROCEEDINGS OF THE FOURTH COMPTON SYMPOSIUM, PTS 1 AND 2: PT 1: THE COMPTON OBSERVATORY IN REVIEW; PT 2: PAPERS AND PRESENTATIONS, 1997, (410): : 892 - 896
  • [28] Multi-wavelength Reflectivity Monitoring on Growth of AlN on Si
    Iyechika, Yasushi
    Tsukui, Masayuki
    Miyano, Kiyotaka
    Takahashi, Hideshi
    2019 COMPOUND SEMICONDUCTOR WEEK (CSW), 2019,
  • [29] Multi-wavelength fluorometry for anaerobic digestion process monitoring
    Morel, E
    Santamaria, K
    Perrier, M
    Guiot, SR
    Tartakovsky, B
    WATER SCIENCE AND TECHNOLOGY, 2005, 52 (1-2) : 465 - 471
  • [30] Validation of ambulatory blood pressure monitoring and pulse transit time
    Liendo Martinez, K. H.
    Lopez-Padilla, D.
    De Miguel Diez, J.
    Villar Alvarez, F.
    Gomez Garcia, T.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60