Sensitivity enhancement of optical plasmon-based sensor for detection of the hemoglobin and glucose: a numerical approach

被引:24
作者
Almawgani, Abdulkarem H. M. [1 ]
Uniyal, Arun [2 ]
Sarkar, Partha [3 ]
Srivastava, Gaurav [4 ]
Pal, Amrindra [5 ,6 ]
Alhawari, Adam R. H. [1 ]
Taya, Sofyan A. [7 ]
Muduli, Arjuna [8 ]
机构
[1] Najran Univ, Coll Engn, Elect Engn Dept, Najran, Saudi Arabia
[2] Inst Technol Gopeshwar, Dept Elect & Commun Engn, Chamoli 246424, Uttaranchal, India
[3] Natl Inst Technol, Dept Elect & Commun Engn, Mahatma Gandhi Rd, Durgapur 713209, W Bengal, India
[4] Univ Allahabad, Dept Elect & Commun, Prayagraj 211002, Uttar Pradesh, India
[5] DIT Univ, Sch Engn & Technol, Dept ECE, Dehra Dun 248009, India
[6] Natl Res Fdn Nepal, Kathmandu 44600, Nepal
[7] Islamic Univ Gaza, Phys Dept, POB 108, Gaza, Palestine
[8] Koneru Lakshmaiah Educ Fdn, Dept Elect & Comm Engn, Vaddeswaram 522302, Andhra Pradesh, India
关键词
Sensitivity enhancement; Hemoglobin detection; Glucose detection; Black phosphorus; RESONANCE; LEVEL;
D O I
10.1007/s11082-023-05219-4
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the proposed surface plasmon resonance sensor, bimetallic plasmonic metal copper (Cu) and platinum (Pt) are coated over the BaF2 prism for the occurrence of the surface plasmon phenomena. The black phosphorous (BP) nano-sheet enhances the sensitivity for detecting water containing the solution, hemoglobin (Hb), and glucose from the body fluid samples. This paper numerically investigated the effect of the bimetal (Cu-Pt) and black phosphorous (BP) on the performance of the Kretschmann configured SPR biosensor with a visible range of 633 nm wavelength. The maximum sensitivity of 495.7 & DEG;/RIU is obtained at a sensing layer of 1.330-1.335. The angular interrogation technique optimizes the thickness of the metals and 2D material for minimum reflectance. The maximum sensitivity of 382.5 & DEG;/RIU and 399.78 & DEG;/RIU are achieved for detecting hemoglobin and glucose, respectively. The proposed work has much better sensitivity than pre-existing SPR biosensors in the Hb and glucose biosensor literature. The proposed paper can advance the research in sensing Hb and glucose in the medical field.
引用
收藏
页数:17
相关论文
共 49 条
[21]   Recent Advances in Optical Biosensors for Environmental Monitoring and Early Warning [J].
Long, Feng ;
Zhu, Anna ;
Shi, Hanchang .
SENSORS, 2013, 13 (10) :13928-13948
[22]   Detection of hemoglobin in blood and urine glucose level samples using a graphene-coated SPR based biosensor [J].
Mostufa, Shahriar ;
Paul, Alok Kumar ;
Chakrabarti, Kisalaya .
OSA CONTINUUM, 2021, 4 (08) :2164-2176
[23]   Modeling of highly improved SPR sensor for formalin detection [J].
Moznuzzaman, Md ;
Islam, Md Rafiqul ;
Hossain, Md Biplob ;
Mehedi, Ibrahim Mustafa .
RESULTS IN PHYSICS, 2020, 16
[24]   Black Phosphorus Nanostructure Based Highly Sensitive and Selective Surface Plasmon Resonance Sensor for Biological and Chemical Sensing: A Review [J].
Nangare, Sopan ;
Patil, Pravin .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2023, 53 (01) :1-26
[25]   SPR Based Biosensing Chip for COVID-19 Diagnosis-A Review [J].
Pandey, Purnendu Shekhar ;
Raghuwanshi, Sanjeev Kumar ;
Shadab, Azhar ;
Ansari, Md Tauseef Iqbal ;
Tiwari, Umesh Kumar ;
Kumar, Santosh .
IEEE SENSORS JOURNAL, 2022, 22 (14) :13800-13810
[26]   Enhancement of the sensitivity of a surface plasmon resonance sensor using a nobel structure based on barium titanate-graphene -silver [J].
Pandey, Purnendu Shekhar ;
Raghuwanshi, Sanjeev Kumar ;
Singh, Yadvendra .
OPTICAL AND QUANTUM ELECTRONICS, 2022, 54 (07)
[27]   Recent Advances in Two-Dimensional Materials-Based Kretschmann Configuration for SPR Sensors: A Review [J].
Pandey, Purnendu Shekhar ;
Raghuwanshi, Sanjeev Kumar ;
Kumar, Santosh .
IEEE SENSORS JOURNAL, 2022, 22 (02) :1069-1080
[28]   Graphene-based nanocomposites for sensitivity enhancement of surface plasmon resonance sensor for biological and chemical sensing: A review [J].
Patil, Pravin O. ;
Pandey, Gaurav R. ;
Patil, Ashwini G. ;
Borse, Vivek B. ;
Deshmukh, Prashant K. ;
Patil, Dilip R. ;
Tade, Rahul S. ;
Nangare, Sopan N. ;
Khan, Zamir G. ;
Patil, Arun M. ;
More, Mahesh P. ;
Veerapandian, Murugan ;
Bari, Sanjay B. .
BIOSENSORS & BIOELECTRONICS, 2019, 139
[29]   EFFECT OF OXIDATION ON THE CHARACTERISTIC LOSS SPECTRA OF ALUMINUM AND MAGNESIUM [J].
POWELL, CJ ;
SWAN, JB .
PHYSICAL REVIEW, 1960, 118 (03) :640-643
[30]   Increasing the specificity of the forensic luminol test for blood [J].
Quickenden, TI ;
Cooper, PD .
LUMINESCENCE, 2001, 16 (03) :251-253