Donor lamella thickness after ultrathin Descemet stripping automated endothelial keratoplasty and its relation to postoperative visual acuity and pre-operative lamella measures

被引:0
作者
van Rooij, Jeroen [1 ]
Engel, Angela [2 ]
Steijger-Vermaat, Petra [3 ]
Molenaar, Annemieke [3 ]
Vigueras-Guillen, Juan Pedro [2 ]
Wubbels, Rene J. [2 ]
机构
[1] Rotterdam Eye Hosp, Schiedamse Vest 180, NL-3011 BH Rotterdam, Netherlands
[2] Rotterdam Ophthalm Inst, Schiedamse Vest 160, NL-3011 BH Rotterdam, Netherlands
[3] ETB BISLIFE, Cornea Dept, Markt 58, NL-1941 BM Beverwijk, Netherlands
关键词
Corneal endothelium; Graft thickness profile; Edema; GRAFT THICKNESS; TISSUE; DSAEK;
D O I
10.1186/s12886-023-03019-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo accurately measure ultrathin Descemet stripping automated endothelial keratoplasty (DSAEK) donor lamella thickness during the first postoperative year and to correlate this with pre-operative and other postoperative measurements.MethodsDonor lamella thickness in 41 eyes undergoing DSAEK for Fuchs endothelial dystrophy (FED) was measured using the Tomey Casia OCT directly after graft preparation and at 1 week and 1, 3, 6 and 12 months postoperatively. Visual acuity and endothelial cell density were measured as the secondary parameters.ResultsIndividual graft thickness profiles were shown to be fairly regular within the optically relevant area. There was a strong and highly significant correlation between the pre- and postoperative lamellar thicknesses at all time points (p < 0.0001). Compared with the measurements directly after preparation at the cornea bank, the lamella thickness decreased by 12% after 12 months. Between 1 and 12 months postoperatively, the lamella thickness (mean +/- SD) changed from 112 +/- 27 mu m to 101 +/- 21 mu m. Best spectacle-corrected visual acuity (BSCVA) changed from 0.46 +/- 0.30 logMAR pre-operatively through 0.36 +/- 0.33 at 1 month to 0.13 +/- 0.16 at 1 year postoperatively. The endothelial cell counts were comparable to those reported in previous studies.ConclusionsThickness profiles of individual grafts were fairly regular within the optically relevant area. A strong relationship between pre- and postoperative graft thicknesses was detected, and ultrathin DSAEK grafts prepared using methods similar to that applied in this study are expected to show a deswelling of around 12% during the first postoperative year. No correlation was detected between graft thickness and BSCVA.
引用
收藏
页数:7
相关论文
共 23 条
[1]   Host and Graft Thickness after Descemet Stripping Endothelial Keratoplasty for Fuchs Endothelial Dystrophy [J].
Ahmed, Kamran A. ;
McLaren, Jay W. ;
Baratz, Keith H. ;
Maguire, Leo J. ;
Kittleson, Katrina M. ;
Patel, Sanjay V. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (04) :490-497
[2]   The Ongoing Debate: Descemet Membrane Endothelial Keratoplasty Versus Ultrathin Descemet Stripping Automated Endothelial Keratoplasty [J].
Busin, Massimo ;
Yu, Angeli Christy .
OPHTHALMOLOGY, 2020, 127 (09) :1160-1161
[3]   Microkeratome-Assisted Preparation of Ultrathin Grafts for Descemet Stripping Automated Endothelial Keratoplasty [J].
Busin, Massimo ;
Patel, Amit K. ;
Scorcia, Vincenzo ;
Ponzin, Diego .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (01) :521-524
[4]   Descemet Endothelial Thickness Comparison Trial A Randomized Trial Comparing Ultrathin Descemet Stripping Automated Endothelial Keratoplasty with Descemet Membrane Endothelial Keratoplasty [J].
Chamberlain, Winston ;
Lin, Charles C. ;
Austin, Ariana ;
Schubach, Nicholas ;
Clover, Jameson ;
McLeod, Stephen D. ;
Porco, Travis C. ;
Lietman, Thomas M. ;
Rose-Nussbaumer, Jennifer .
OPHTHALMOLOGY, 2019, 126 (01) :19-26
[5]   Technique for Preparing Ultrathin and Nanothin Descemet Stripping Automated Endothelial Keratoplasty Tissue [J].
Cheung, Albert Y. ;
Hou, Joshua H. ;
Bedard, Peter ;
Grimes, Veronique ;
Buckman, Natalie ;
Eslani, Medi ;
Holland, Edward J. .
CORNEA, 2018, 37 (05) :661-666
[6]   A Randomized Multicenter Clinical Trial of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) versus DSAEK [J].
Dickman, Mor M. ;
Kruit, Pieter J. ;
Remeijer, Lies ;
van Rooij, Jeroen ;
Van der Lelij, Allegonda ;
Wijdh, Robert H. J. ;
van den Biggelaar, Frank J. H. M. ;
Berendschot, Tos T. J. M. ;
Nuijts, Rudy M. M. A. .
OPHTHALMOLOGY, 2016, 123 (11) :2276-2284
[7]   Practice patterns of corneal transplantation in Europe: first report by the European Cornea and Cell Transplantation Registry [J].
Dunker, Suryan L. ;
Armitage, W. John ;
Armitage, Margareta ;
Brocato, Lucia ;
Figueiredo, Francisco C. ;
Heemskerk, Martin B. A. ;
Hjortdal, Jesper ;
Jones, Gary L. A. ;
Konijn, Cynthia ;
Nuijts, Rudy M. M. A. ;
Lundstrom, Mats ;
Dickman, Mor M. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (07) :865-869
[8]   Descemet Membrane Endothelial Keratoplasty versus Ultrathin Descemet Stripping Automated Endothelial Keratoplasty A Multicenter Randomized Controlled Clinical Trial [J].
Dunker, Suryan L. ;
Dickman, Mor M. ;
Wisse, Robert P. L. ;
Nobacht, Siamak ;
Wijdh, Robert H. J. ;
Bartels, Marjolijn C. ;
Tang, Mei L. ;
van den Biggelaar, Frank J. H. M. ;
Kruit, Pieter J. ;
Nuijts, Rudy M. M. A. .
OPHTHALMOLOGY, 2020, 127 (09) :1152-1159
[9]   Thinning rate over 24 months in ultrathin DSAEK [J].
Fenech, Matthew T. ;
Coco, Giulia ;
Pagano, Luca ;
Gadhvi, Kunal A. ;
Titley, Mitchell ;
Levis, Hannah J. ;
Parekh, Mohit ;
Kaye, Stephen B. ;
Romano, Vito .
EYE, 2023, 37 (04) :655-659
[10]   Descemet-stripping automated endothelial keratoplasty [J].
Gorovoy, Mark S. .
CORNEA, 2006, 25 (08) :886-889