Transition metal doped ZIF-8 for the detection of the heavy metal Hg(II)

被引:2
作者
Chen, Xin Zhe [1 ]
Wu, Yang [1 ]
Xu, Chen [1 ]
Wang, Zi Jun [2 ,3 ,4 ]
Liu, Min Min [1 ,3 ]
机构
[1] Shihezi Univ, Sch Chem & Chem Engn, Shihezi, Xinjiang, Peoples R China
[2] Shihezi Univ, Sch Chem & Chem Engn, Shihezi, Xinjiang, Peoples R China
[3] Carbon Neutralizat & Environm Catalyt Technol Lab, Key Lab Green Proc Chem Engn Xinjiang Bingtuan, Shihezi, Xinjiang, Peoples R China
[4] Carbon Neutralizat & Environm Catalyt Technol Lab, Key Lab Green Proc Chem Engn Xinjiang Bingtuan, Shihezi 832003, Xinjiang, Peoples R China
关键词
heavy metal detection; metal-organic framework; transition metal; WATER; REMOVAL; IONS; MOFS; NANOCOMPOSITE; NANOPARTICLES; PERFORMANCE; EFFICIENT; SAMPLES; PB(II);
D O I
10.1002/jccs.202300457
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The effects of heavy metals such as Hg(II) and Pb(II) on the human body are profound. Moreover, they pose significant concerns due to industrial development. Thus, the rapid and stable detection of heavy metal ions and related chemicals has emerged as an urgent issue. The application of Differential Pulse Stripping Voltammetry (DPSV) facilitated accurate and rapid detection of Hg2+ utilizing MOF materials and ZIF-8 as detection agents. Pure ZIF-8 served as the substrate material. Copper or nickel ions were individually introduced into the substrate material. This process resulted in the formation of bimetallic MOF materials. These materials were designated as CuZn and NiZn, respectively. Transition metal-doped materials were used to modify the glassy carbon electrode (GCE), resulting in a substantial enhancement in the detection performance of Hg2+. The CuZn/GCE configuration demonstrated the most significant enhancement. When compared to a GCE modified with pure ZIF-8, both sensitivity and the detection limit for free Hg2+ in the environment experienced increases of 450% and 64%, respectively. Stability and repeatability tests were conducted on the CuZn-modified GCE. Results indicated that the electrode proved to be very stable and showed strong selectivity in the presence of interfering ions. The sensor modified with CuZn shows promising potential for monitoring trace Hg2+ levels.
引用
收藏
页码:409 / 419
页数:11
相关论文
共 42 条
[1]   Zeolitic Imidazolate Frameworks (ZIF-8) for Biomedical Applications: A Review [J].
Abdelhamid, Hani Nasser .
CURRENT MEDICINAL CHEMISTRY, 2021, 28 (34) :7023-7075
[2]   Heavy Metal Contamination of Irrigation Water, Soil, and Vegetables in a Multi-industry District of Bangladesh [J].
Ahmed, Minhaz ;
Matsumoto, Masaru ;
Kurosawa, Kiyoshi .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2018, 12 (04) :531-542
[3]   Carbon Nanomaterials for the Treatment of Heavy Metal-Contaminated Water and Environmental Remediation [J].
Baby, Rabia ;
Saifullah, Bullo ;
Hussein, Mohd Zobir .
NANOSCALE RESEARCH LETTERS, 2019, 14 (01)
[4]   Assembling reduced graphene oxide with sulfur/nitrogen- "hooks" for electrochemical determination of Hg(II) [J].
Bi, Cheng-Cheng ;
Ke, Xu-Xu ;
Chen, Xing ;
Weerasooriya, Rohan ;
Hong, Zhan-Yong ;
Wang, Lian-Chao ;
Wu, Yu-Cheng .
ANALYTICA CHIMICA ACTA, 2020, 1100 :31-39
[5]   Doping ZIF-67 with transition metals results in bimetallic centers for electrochemical detection of Hg(II) [J].
Chen, Xing ;
Zhao, Ji-Xing ;
Wang, Jia-Wei ;
Liu, Yao ;
Wang, Lian-Chao ;
Weerasooriya, Rohan ;
Wu, Yu-Cheng .
ELECTROCHIMICA ACTA, 2021, 387
[6]   Rapid microwave-assisted construction of ZIF-8 derived ZnO and ZnO@Ta2O5 nanocomposite as an efficient electrode for methanol and urea electro-oxidation [J].
Devarayapalli, K. C. ;
Vattikuti, S. V. Prabhakar ;
Yoo, Ki Soo ;
Nagajyothi, P. C. ;
Shim, Jaesool .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 878
[7]   Using ZIF-8 to synthesize ZnO/C composite with enhanced photocatalytic property [J].
Ding, Aimin ;
Tai, Wenqing ;
Li, Qiaoqian ;
Liu, Xue ;
Li, Hongying ;
Yao, Chengli .
JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2023, 20 (10) :2517-2525
[8]   Adsorptive Performance of MOFs and MOF Containing Composites for Clean Energy and Safe Environment [J].
Emam, Hossam E. ;
Abdelhameed, Reda M. ;
Ahmed, Hanan B. .
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2020, 8 (05)
[9]   H2S interaction with HKUST-1 and ZIF-8 MOFs: A multitechnique study [J].
Ethiraj, Jayashree ;
Bonino, Francesca ;
Lamberti, Carlo ;
Bordiga, Silvia .
MICROPOROUS AND MESOPOROUS MATERIALS, 2015, 207 :90-94
[10]   ZnFe2O4 Nanoparticles for Electrochemical Determination of Trace Hg(II), Pb(II), Cu(II), and Glucose [J].
Fan, Changchun ;
Chen, Long ;
Jiang, Rong ;
Ye, Jiahui ;
Li, Haoquan ;
Shi, Yulin ;
Luo, Yun ;
Wang, Gang ;
Hou, Juan ;
Guo, Xuhong .
ACS APPLIED NANO MATERIALS, 2021, 4 (04) :4026-4036