The EURADOS CR-39 Quality task for the optimisation and harmonisation of personal neutron dosimetry with CR-39 (PADC)

被引:2
|
作者
Bolzonella, Matteo [1 ]
Caresana, Marco [1 ]
Gilvin, Philip J. [2 ]
Yukihara, Eduardo G. [3 ]
Chevallier, Marie-Anne [4 ]
机构
[1] Politecn Milan, DOE, Via Lambruschini 4, I-20156 Milan, Italy
[2] UK Hlth Secur Agcy, Personal Dosimetry Serv, Didcot OX11 0RQ, England
[3] Paul Scherrer Inst, Dept Radiat Safety & Secur, Forsch str 111, CH-5232 Villigen, Switzerland
[4] Inst Radioprotect & Surete Nucleaire IRSN, Dosimetry Res Dept, BP 17,31 Ave Div Leclerc, F-92260 Fontenay Aux Roses, France
关键词
D O I
10.1093/rpd/ncad068
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
CR-39 (PADC) nuclear track detectors are among the most widespread devices used for personal neutron dosimetry; however, some issues related to the variable material quality of the CR-39 polymer hinder the performance of CR-39-based dosemeters. For this reason, the Working Group 2 (WG2) of the European Radiation Dosimetry Group (EURADOS) has recently launched the CR-39 Quality task, a project aimed at improving and harmonising personal neutron dosimetry with CR-39 in Europe. Whitin this task, a close collaboration among researchers, individual monitoring services and dosemeter grade CR-39 manufacturers is achieved, thus facilitating the direct dialog between producer and consumer to reach an optimised material for personal neutron dosimetry applications.
引用
收藏
页码:1867 / 1871
页数:5
相关论文
共 50 条
  • [41] CR-39 USED AS A DETECTOR IN A NEUTRON DOSIMETER
    VAREILLE, JC
    DECOSSAS, JL
    SADAKA, S
    TEYSSIER, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 17 (03): : 280 - 284
  • [42] The Influence of Neutron Irradiation in CR-39 Polymer
    Prasher, Sangeeta
    Kumar, Mukesh
    Singh, Surinder
    ORIENTAL JOURNAL OF CHEMISTRY, 2015, 31 (02) : 1201 - 1204
  • [43] THE LLNL CR-39 PERSONNEL NEUTRON DOSIMETER
    HANKINS, DE
    HOMANN, S
    WESTERMARK, J
    RADIATION PROTECTION DOSIMETRY, 1988, 23 (1-4) : 195 - 198
  • [44] Progress report of the CR-39 neutron personal monitoring service at PSI
    Fiechtner, A.
    Boschung, M.
    Wernli, C.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 237 - 240
  • [45] Progress towards the development of a CR-39 fast neutron personal dosemeter
    Djeffal, S.
    Lounis, Z.
    Nuclear Tracks and Radiation Measurements, 1991, 19 (1-4): : 457 - 460
  • [46] ON THE USE OF CR-39 SSNTD AS A FAST-NEUTRON PERSONAL DOSIMETER
    SPURNY, F
    PINAK, M
    TUREK, K
    RADIATION PROTECTION DOSIMETRY, 1987, 20 (1-2) : 81 - 84
  • [47] STRUCTURE PROPERTY CORRELATION FOR CR-39 POLYCARBONATE IN DOSIMETRY
    YANG, CS
    DAVIS, CR
    GROEGER, JH
    HUANG, SJ
    JOHNSON, JF
    HADLOCK, DE
    PARKHURST, MA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 547 - 550
  • [48] Gamma dosimetry with CR-39 etch track detector
    Matiullah
    Dogar, Ashiq Hussain
    Ahmad, Nasir
    Amin, Masood
    Kudo, Katsuhisa
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (6 A): : 3761 - 3762
  • [49] STRUCTURE PROPERTY CORRELATION FOR CR-39 POLYCARBONATE IN DOSIMETRY
    YANG, CS
    HUANG, SJ
    JOHNSON, JF
    HADLOCK, DE
    PARKHURST, MA
    HEALTH PHYSICS, 1985, 49 (01): : 142 - 143
  • [50] Gamma dosimetry with CR-39 etch track detector
    Matiullah
    Dogar, AH
    Ahmad, N
    Amin, M
    Kudo, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1999, 38 (6A): : 3761 - 3762