The EURADOS CR-39 Quality task for the optimisation and harmonisation of personal neutron dosimetry with CR-39 (PADC)

被引:2
|
作者
Bolzonella, Matteo [1 ]
Caresana, Marco [1 ]
Gilvin, Philip J. [2 ]
Yukihara, Eduardo G. [3 ]
Chevallier, Marie-Anne [4 ]
机构
[1] Politecn Milan, DOE, Via Lambruschini 4, I-20156 Milan, Italy
[2] UK Hlth Secur Agcy, Personal Dosimetry Serv, Didcot OX11 0RQ, England
[3] Paul Scherrer Inst, Dept Radiat Safety & Secur, Forsch str 111, CH-5232 Villigen, Switzerland
[4] Inst Radioprotect & Surete Nucleaire IRSN, Dosimetry Res Dept, BP 17,31 Ave Div Leclerc, F-92260 Fontenay Aux Roses, France
关键词
D O I
10.1093/rpd/ncad068
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
CR-39 (PADC) nuclear track detectors are among the most widespread devices used for personal neutron dosimetry; however, some issues related to the variable material quality of the CR-39 polymer hinder the performance of CR-39-based dosemeters. For this reason, the Working Group 2 (WG2) of the European Radiation Dosimetry Group (EURADOS) has recently launched the CR-39 Quality task, a project aimed at improving and harmonising personal neutron dosimetry with CR-39 in Europe. Whitin this task, a close collaboration among researchers, individual monitoring services and dosemeter grade CR-39 manufacturers is achieved, thus facilitating the direct dialog between producer and consumer to reach an optimised material for personal neutron dosimetry applications.
引用
收藏
页码:1867 / 1871
页数:5
相关论文
共 50 条
  • [1] COPOLYMERS OF CR-39 FOR NEUTRON DOSIMETRY
    YANG, CS
    HUANG, SJ
    JOHNSON, JF
    HADLOCK, DE
    PARKHURST, MA
    HEALTH PHYSICS, 1986, 50 : S19 - S19
  • [2] CR-39 acceptance test and optimisation for fast neutron dosimetry applications
    Fantuzzi, E
    Morelli, B
    Falangi, G
    Patrizii, L
    Togo, V
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 573 - 578
  • [3] CR-39 acceptance test and optimisation for fast neutron dosimetry applications
    Fantuzzi, E
    Morelli, B
    Falangi, G
    Patrizii, L
    Togo, V
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A573 - A578
  • [4] Optimization of CR-39 for fast neutron dosimetry applications
    Vilela, E
    Fantuzzi, E
    Giacomelli, G
    Giorgini, M
    Morelli, B
    Patrizii, L
    Serra, P
    Togo, V
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 437 - 442
  • [5] Neutron dosimetry at low and high fluences with CR-39
    Meyer, P
    Groetz, JE
    Fromm, M
    Lacourt, A
    Chambaudet, A
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 423 - 428
  • [6] TRIALS AND TRIBULATIONS OF PROCESSING CR-39 FOR NEUTRON DOSIMETRY
    PARKHURST, MA
    HAGGARD, DL
    TOMERAASEN, PL
    HADLOCK, DE
    HEALTH PHYSICS, 1984, 47 (01): : 155 - 155
  • [7] Optimization of CR-39 for fast neutron dosimetry applications
    Vilela, E.
    Fantuzzi, E.
    Giacomelli, G.
    Giorgini, M.
    Morelli, B.
    Patrizii, L.
    Serra, P.
    Togo, V.
    Radiation Measurements, 1999, 31 (01): : 437 - 442
  • [8] IMPROVEMENT ON CR-39 MANUFACTURING FOR NEUTRON DOSIMETRY APPLICATIONS
    LEMBO, L
    CIVOLANI, O
    PATRIZII, L
    LODI, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 633 - 636
  • [9] NEW ETCHING CONDITIONS FOR CR-39 FOR NEUTRON DOSIMETRY
    AZIMIGARAKANI, D
    BOSCHUNG, M
    WERNLI, C
    RADIATION PROTECTION DOSIMETRY, 1991, 35 (02) : 93 - 98
  • [10] NEUTRON DOSIMETRY STUDIES USING CR-39 PLASTIC
    HARRISON, KG
    PERKS, CA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 374 - 374