Whole-body MRI in children and adolescents: Can T2-weighted Dixon fat-only images replace standard T1-weighted images in the assessment of bone marrow?

被引:3
作者
de Horatio, Laura Tanturri [1 ,2 ,6 ]
Zadig, Pia K. [1 ,3 ]
von Brandis, Elisabeth [4 ,5 ]
Rosendahl, Karen [1 ,3 ]
Avenarius, Derk F. M. [1 ,3 ]
机构
[1] Arctic Univ Norway, Dept Clin Med, UiT, N-9037 Tromso, Norway
[2] Osped Pediatr Bambino Gesu, Dept Pediat Radiol, I-00165 Rome, Italy
[3] Univ Hosp North Norway, Dept Radiol, N-9038 Tromso, Norway
[4] Oslo Univ Hosp, Div Radiol & Nucl Med, N-0372 Oslo, Norway
[5] Univ Oslo, Inst Clin Med, Fac Med, N-0318 Oslo, Norway
[6] Piazza S Onofrio 4, I-00165 Rome, Italy
关键词
Whole-body MRI; DIXON fat-only; Bone marrow; Children; Adolescents; SUPPRESSION; DIAGNOSIS;
D O I
10.1016/j.ejrad.2023.110968
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: When performing whole-body MRI for bone marrow assessment in children, optimizing scan time is crucial. The aim was to compare T2 Dixon fat-only and TSE T1-weighted sequences in the assessment of bone marrow high signal areas seen on T2 Dixon water-only in healthy children and adolescents. Materials and methods: Whole-body MRIs from 196 healthy children and adolescents aged 6 to 19 years (mean 12.0) were obtained including T2 TSE Dixon and T1 TSE-weighted images. Areas with increased signal on T2 Dixon water-only images were scored using a novel, validated scoring system and classified into "minor" or "major" findings according to size and intensity, where "major" referred to changes easily being misdiagnosed as pathology in a clinical setting. Areas were assessed for low signal on T2 Dixon fat-only images and, after at least three weeks to avoid recall bias, on the T1-weighted sequence by two experienced pediatric radiologists. Results: 1250 high signal areas were evaluated on T2 Dixon water-only images. In 1159/1250 (92.7%) low signal was seen on both T2 Dixon fat-only and T1-weighted sequences while in 24 (1.9%) it was not present on either sequence, with an absolute agreement of 94.6%. Discordant findings were found in 67 areas, of which in 18 (1.5%) low signal was visible on T1-weighted images alone and in 49 (3.9%) on T2 Dixon fat-only alone. The overall kappa value between the two sequences was 0.39. The agreement was higher for major as compared to minor findings (kappa values of 0.69 and 0.29, respectively) and higher for the older age groups. Conclusion: T2 Dixon fat-only can replace T1-weighted sequence on whole-body MRI for bone marrow assessment in children over the age of nine, thus reducing scan time.
引用
收藏
页数:8
相关论文
共 29 条
[1]   Diagnostic Accuracy of Standalone T2 Dixon Sequence Compared with Conventional MRI in Sacroiliitis [J].
Athira, R. ;
Cannane, Seetharaman ;
Thushara, R. ;
Poyyamoli, Santhosh ;
Nedunchelian, Meena .
INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2022, 32 (03) :314-323
[2]   Useful internal standards for distinguishing infiltrative marrow pathology from hematopoietic marrow at MRI [J].
Carroll, KW ;
Feller, JF ;
Tirman, PFJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02) :394-398
[3]   MR Imaging of Pediatric Bone Marrow [J].
Chan, Brian Y. ;
Gill, Kara G. ;
Rebsamen, Susan L. ;
Nguyen, Jie C. .
RADIOGRAPHICS, 2016, 36 (06) :1911-1930
[4]   Whole-body MRI: non-oncological applications in paediatrics [J].
Damasio, Maria Beatrice ;
Magnaguagno, Francesca ;
Stagnaro, Giorgio .
RADIOLOGIA MEDICA, 2016, 121 (05) :454-461
[5]   Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System [J].
Del Grande, Filippo ;
Santini, Francesco ;
Herzka, Daniel A. ;
Aro, Michael R. ;
Dean, Cooper W. ;
Gold, Garry E. ;
Carrino, John A. .
RADIOGRAPHICS, 2014, 34 (01) :217-233
[6]   Fat Suppression with Dixon Techniques in Musculoskeletal Magnetic Resonance Imaging: A Pictorial Review [J].
Guerini, Henri ;
Omoumi, Patrick ;
Guichoux, Francois ;
Vuillemin, Valerie ;
Morvan, Gerard ;
Zins, Marc ;
Thevenin, Fabrice ;
Drape, Jean Luc .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2015, 19 (04) :335-347
[7]   Whole-body MRI of bone marrow: A review [J].
Hynes, John P. ;
Hughes, Nicola ;
Cunningham, Patricia ;
Kavanagh, Eoin C. ;
Eustace, Stephen J. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (06) :1687-1701
[8]  
Korchi AM, 2014, MINERVA PEDIATR, V66, P169
[9]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[10]  
Lins Carolina Freitas, 2021, Radiol Bras, V54, P33, DOI [10.1590/0100-3984.2019.0086, 10.1590/0100-3984.2019.0086]