Experimental comparison of evacuated tube solar air heater based on energy and exergy analyses with environmental and economic (4-E) study

被引:19
作者
Agrawal, Anshu [1 ]
Kumar, Amit [1 ]
Parekh, A. D. [1 ]
机构
[1] Sardar Vallabhbhai Natl Inst Technol, Dept Mech Engn, Surat 395007, Gujarat, India
关键词
air flow rates; energy; environmental and economic (4-E) analyses; evacuated tube collector; exergy; sensible heat storage; solar air heater; PHASE-CHANGE MATERIAL; THERMAL PERFORMANCE; COLLECTOR; DESIGN;
D O I
10.1002/ep.14116
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For the purpose of low-medium air heating applications like timber seasoning, HVAC, agricultural & food drying, space heating and desalination, there is requirement of hot air. Solar air heaters are the promising systems to satisfy these requirements in a very inexpensive manner. Due to higher efficiency at higher operating temperature and lower cost, evacuated tube collectors (ETCs) are preferred for solar air heating. In this manuscript, the comparative parametric study of two similar sets of evacuated tube solar air heater (ETSAH) is performed. The comparison is based on energy & exergy analyses, and also presents the environmental and economic study (4E analyses). Each set is fabricated using mild steel (M.S.) along with 50 evacuated tubes with total collector area of 8.46 m2. The experimental investigations are made at diverse flow rates, with and without using conventional reflectors. Without incorporating any additional heat storage unit, the system provides average hot air temperature of 76.13 degrees C when average solar intensity was 502.68 W/m(2) during 11 h of operation from 09:00 to 20:00 h. ETC's absorber glass and the M.S. material was observed to have significant energy storage and discharge. The single set of ETSAH has CO2 mitigation of 89.20 tons with 2.05 years of energy payback period, which is significantly low as compared to its 20 years of lifespan. For the optimum system performance the cost of generated hot air is 0.00048 $/kg, which is considerably low.
引用
收藏
页数:15
相关论文
共 50 条
[31]   Energy and exergy analyses of a new solar air heater with circular-type turbulators having different relief angles [J].
Acir, Adem ;
Ata, Ismail ;
Sahin, Izzet .
INTERNATIONAL JOURNAL OF EXERGY, 2016, 20 (01) :85-104
[32]   Energy and exergy experimental analysis for innovative finned plate solar air heater [J].
Alrashidi, Abdullah ;
Altohamy, Ahmed A. ;
Abdelrahman, M. A. ;
Elsemary, Ismail M. M. .
CASE STUDIES IN THERMAL ENGINEERING, 2024, 59
[33]   Experimental study of a nanofluid-based indirect solar cooker: Energy and exergy analyses [J].
Hosseinzadeh, Mohammad ;
Sadeghirad, Reza ;
Zamani, Hosein ;
Kianifar, Ali ;
Mirzababaee, Seyyed Mahdi ;
Faezian, Ali .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2021, 221
[34]   Parametric study of evacuated tube collector solar air heater with inserted baffles on thermal network for low-temperature applications [J].
Venkatramanan, R. ;
Arjunan, T. V. ;
Seenivasan, D. ;
Kumar, A. Veera .
JOURNAL OF CLEANER PRODUCTION, 2022, 367
[35]   Exergy, energy, and economic analyses of pyramid solar still integrated with solar water heater [J].
Kanojiya, Nilesh C. ;
Shahare, Achal S. ;
Sambare, Ritesh K. .
ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (02) :4804-4821
[36]   Experimental study on a humidification and dehumidification desalination system of solar air heater with evacuated tubes [J].
Li, Xing ;
Yuan, Guofeng ;
Wang, Zhifeng ;
Li, Hongyong ;
Xu, Zhibin .
DESALINATION, 2014, 351 :1-8
[37]   Experimental Studies on Energy and Exergy Analysis of a Single-Pass Parallel Flow Solar Air Heater [J].
Dheep, G. Raam ;
Sreekumar, A. .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (01)
[38]   Experimental investigation of humidification-dehumidification desalination system based on double-ends open evacuated tube solar air heater with inbuilt heat storage unit [J].
Tiwari, Abhishek ;
Kumar, Amit .
JOURNAL OF ENERGY STORAGE, 2024, 89
[39]   ECONOMIC-ENVIRONMENTAL COMPARISON BETWEEN FLAT PLATE AND EVACUATED TUBE SOLAR COLLECTORS [J].
Hoffmann, R. ;
Brondani, M. ;
Pappis, F. ;
Friderichs, A. ;
Serafini, S. ;
Foletto, E. L. .
GLOBAL NEST JOURNAL, 2014, 16 (06) :1100-1109
[40]   Experimental investigation of a novel solar air heater based on heat pipe vacuum tube collector integrated with finned-tube heat exchanger [J].
Sachdeva, Anshul ;
Chandrashekara, M. ;
Yadav, Avadhesh .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (20) :10917-10936