Performance evaluation on full-scale proton exchange membrane fuel cell: Mutual validation of one-dimensional, three-dimensional and experimental investigations

被引:15
作者
Zhang, Yong [1 ]
He, Shirong [1 ]
Jiang, Xiaohui [1 ]
Fang, Haoyan [2 ]
Wang, Zhuo [1 ]
Cao, Jing [3 ]
Yang, Xi [4 ]
Li, Qiming [5 ]
机构
[1] Univ Shanghai Sci & Technol, Coll Mech Engn, Shanghai 200093, Peoples R China
[2] SUNY Stony Brook, Dept Mat Sci & Chem Engn, Stony Brook, NY 11794 USA
[3] Wuhan Troowin Power Syst Technol Co Ltd, Wuhan 430056, Hubei, Peoples R China
[4] Shanghai Hydrogen Prop Technol Co Ltd, Shanghai 201800, Peoples R China
[5] Hunan Univ, Coll Mech & Vehicle Engn, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金; 上海市自然科学基金;
关键词
Full-scale PEMFC; 1D and 3D; Experimental validation; CFD model; Ionomer model; Performance evaluation; GAS-DIFFUSION LAYERS; MULTIPHASE SIMULATION; ELECTRODE; DESIGN;
D O I
10.1016/j.enconman.2023.117905
中图分类号
O414.1 [热力学];
学科分类号
摘要
The coupling of multiple physical processes such as gas multi-component transport, gas-liquid multiphase flow, and electrochemical reactions within the proton exchange membrane fuel cell (PEMFC) makes its hydrothermal management exceptionally complicated. Therefore, the complex heat and mass transfer processes in the full-scale PEMFC are investigated in single cell with single channel serpentine flow field (FF). Firstly, the reliability of the proposed three-dimensional (3D) computational fluid dynamics (CFD) numerical model is verified by using the experimental test results of a single cell. Among them, the trend of simulation and experiment performance curves is consistent, and the minimum error of current density is 0.665%. Secondly, the ionomer model of cathode catalyst layer (CCL) is considered in CFD simulation, which is closer to the actual working condition of fuel cell (FC). The resistance of ionomer film and liquid water film mainly affects the diffusion rate of oxygen in CCL, resulting in a decrease in both current density values and power density values. Subsequently, the electrochemical reaction platform of one-dimensional (1D) FC is constructed, and the performance curves of multiscale FCs are analyzed. The results demonstrate that the error of stack level is the largest, followed by single cell and single channel is the smallest. Finally, the 1D numerical model and the 3D PEMFC multiphase flow CFD model are utilized to investigate the cell voltage losses in the bionic spider flow field, the variable path flow field, and the serpentine flow field, respectively, under different operating conditions.
引用
收藏
页数:19
相关论文
共 68 条
  • [1] An overview of proton exchange membranes for fuel cells: Materials and manufacturing
    Ahmad, Shahbaz
    Nawaz, Tahir
    Ali, Asghar
    Orhan, Mehmet Fatih
    Samreen, Ayesha
    Kannan, Arunachala M.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (44) : 19086 - 19131
  • [2] Bai XY, 2023, J Clean Prod, P410
  • [3] A MATHEMATICAL-MODEL OF THE SOLID-POLYMER-ELECTROLYTE FUEL-CELL
    BERNARDI, DM
    VERBRUGGE, MW
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1992, 139 (09) : 2477 - 2491
  • [4] Influence of catalyst structure on PEM fuel cell performance - A numerical investigation
    Carcadea, E.
    Varlam, M.
    Marinoiu, A.
    Raceanu, M.
    Ismail, M. S.
    Ingham, D. B.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (25) : 12829 - 12841
  • [5] Proton exchange membrane fuel cell stack consistency: Evaluation methods, influencing factors, membrane electrode assembly parameters and improvement measures
    Chen, Dongfang
    Pei, Pucheng
    Li, Yuehua
    Ren, Peng
    Meng, Yining
    Song, Xin
    Wu, Ziyao
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2022, 261
  • [6] Performance of polymer electrolyte membrane fuel cell (PEMFC) stacks Part I. Evaluation and simulation of an air-breathing PEMFC stack
    Chu, D
    Jiang, RZ
    [J]. JOURNAL OF POWER SOURCES, 1999, 83 (1-2) : 128 - 133
  • [7] Comparative studies of polymer electrolyte membrane fuel cell stack and single cell
    Chu, D
    Jiang, RZ
    [J]. JOURNAL OF POWER SOURCES, 1999, 80 (1-2) : 226 - 234
  • [8] 3D effects of water-saturation distribution on polymeric electrolyte fuel cell (PEFC) performance
    Cordiner, Stefano
    Lanzani, Simon Pietro
    Mulone, Vincenzo
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (16) : 10366 - 10375
  • [9] Ex-situ characterisation of gas diffusion layers for proton exchange membrane fuel cells
    El-kharouf, Ahmad
    Mason, Thomas J.
    Brett, Dan J. L.
    Pollet, Bruno G.
    [J]. JOURNAL OF POWER SOURCES, 2012, 218 : 393 - 404
  • [10] 1D and 3D numerical simulations in PEM fuel cells
    Falcao, D. S.
    Gomes, P. J.
    Oliveira, V. B.
    Pinho, C.
    Pinto, A. M. F. R.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (19) : 12486 - 12498