Bulk-fill composite in challenging cavities: conversion rate, solubility, and water absorption analysis

被引:0
作者
Ozturk, Asu Nur Sandikci [1 ]
Harorli, Osman Tolga [1 ]
机构
[1] Akdeniz Univ, Fac Dent, Dept Restorat Dent, TR-07070 Antalya, Turkiye
关键词
Polymerization; Resins; Curing lights; Fourier analysis; Solubility; LIGHT-CURING UNITS; RESIN-BASED COMPOSITES; DENTAL COMPOSITES; MECHANICAL-PROPERTIES; FRACTURE-RESISTANCE; SORPTION; DISTANCE; CURE; POLYMERIZATION; PERFORMANCE;
D O I
10.1007/s10266-023-00873-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
In a deep, curved cavity, polymerization of a bulk fill composite can be challenging. The aim of this study was to investigate the solubility, water absorption, and conversion rate of bulk-fill composite samples prepared using molds with various slope angles. Bulk-fill composite resin (Filtek One Bulk Fill) was placed into cylindrical Teflon molds with a depth of 4 mm, angled at varying degrees (90 degrees, 75 degrees, 60 degrees, 45 degrees). Two different LED light-curing units (VALO Cordless, iLed Curing Light) were used to cure the samples. Polymerizations were performed at three different distances (0 mm, 2 mm, and 4 mm). Five samples per group were used, resulting in a total of 24 groups. The Fourier Transform Infrared Spectrometer was utilized to evaluate the conversion levels of the samples. Water sorption and solubility values were determined by storing the composites in distilled water at 37 degrees C for 21 days. The VALO light-curing unit applied closest to samples inserted in a 90 degrees angulation mold had the highest mean degree of conversion (41.55%), while iLED light-curing unit group that applied from 4 mm to the samples inserted in a 45 degrees angulation mold had the lowest mean conversion (8.97%). The angle of the cavity and the distance at which the light-curing unit is applied significantly affected bulk-fill composite resin conversion. In addition, the choice of light-curing unit impacted the conversion levels. However, with the tested conditions, the water sorption and solubility values of polymerized composite resin samples remain unaffected by these factors.
引用
收藏
页码:718 / 728
页数:11
相关论文
共 48 条
[1]  
Abed YA., 2015, TANTA DENT J, V12, P71, DOI DOI 10.1016/J.TDJ.2015.01.003
[2]   Color stability, conversion, water sorption and solubility of dental composites formulated with different photoinitiator systems [J].
Albuquerque, Pedro Paulo A. C. ;
Moreira, Allana D. L. ;
Moraes, Rafael R. ;
Cavalcante, Larissa M. ;
Schneider, Luis Felipe J. .
JOURNAL OF DENTISTRY, 2013, 41 :E67-E72
[3]   Long-term sorption and solubility of bulk-fill and conventional resin-composites in water and artificial saliva [J].
Alshali, Ruwaida Z. ;
Salim, Nesreen A. ;
Satterthwaite, Julian D. ;
Silikas, Nick .
JOURNAL OF DENTISTRY, 2015, 43 (12) :1511-1518
[4]   Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals [J].
Alshali, Ruwaida Z. ;
Silikas, Nick ;
Satterthwaite, Julian D. .
DENTAL MATERIALS, 2013, 29 (09) :E213-E217
[5]   Effect of inhomogeneity of light from light curing units on the surface hardness of composite resin [J].
Arikawa, Hiroyuki ;
Kanie, Takahito ;
Fujii, Koichi ;
Takahashi, Hideo ;
Ban, Seiji .
DENTAL MATERIALS JOURNAL, 2008, 27 (01) :21-28
[6]   Sorption, solubility, shrinkage and mechanical properties of "low-shrinkage" commercial resin composites [J].
Boaro, Leticia C. ;
Goncalves, Flavia ;
Guimaraes, Thayse C. ;
Ferracane, Jack L. ;
Pfeifer, Carmem S. ;
Braga, Roberto R. .
DENTAL MATERIALS, 2013, 29 (04) :398-404
[7]  
Brokos Ioannis, 2012, Prim Dent J, V1, P11
[8]   Predicting transmitted irradiance through CAD/CAM resin composite crowns in a simulated clinical model [J].
Butterhof, Maximilian ;
Ilie, Nicoleta .
DENTAL MATERIALS, 2021, 37 (06) :998-1008
[9]   Influence of radiant exposure on contraction stress, degree of conversion and mechanical properties of resin composites [J].
Calheiros, Fernanda C. ;
Kawano, Yoshio ;
Stansbury, Jeffrey W. ;
Braga, Roberto R. .
DENTAL MATERIALS, 2006, 22 (09) :799-803
[10]   Influence of Different Cordless Light-emitting-diode Units and Battery Levels on Chemical, Mechanical, and Physical Properties of Composite Resin [J].
Cardoso, I. O. ;
Machado, A. C. ;
Teixeira, D. N. R. ;
Basilio, F. C. ;
Marletta, A. ;
Soares, P., V .
OPERATIVE DENTISTRY, 2020, 45 (04) :377-386