Evaluation of the proximal contact tightness in class II resin composite restorations using different contact forming instruments: a 1-year randomized controlled clinical trial

被引:8
作者
Abbassy, Karim M. [1 ]
Elmahy, Waleed A. [1 ]
Holiel, Ahmed A. [1 ]
机构
[1] Alexandria Univ, Fac Dent, Conservat Dent Dept, Alexandria, Egypt
关键词
Proximal contact; Sectional matrix; Contact forming instrument; Composite restoration; Dentistry; Dental restoration; Permanent; DENTISTS; HARDNESS; SYSTEMS; TEETH;
D O I
10.1186/s12903-023-03462-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Proper proximal contact in direct composite restorations is crucial for periodontal health. Over a one-year period, this study was conducted to assess successive biological changes in proximal contact tightness PCT in class II direct composite restorations and the adjacent teeth by applying sectional matrix system along with different contact forming instruments.Methods 72 direct compound class II composite restorations were performed in patients aged 18-40 years and divided into 4 groups: Group I (n = 18): proximal contact was restored with Palodent plus sectional matrix system, Group II (n = 18): Trimax as contact forming instrument, Group III (n = 18): Perform as contact forming instrument and Group IV (n = 18): Contact pro as contact forming instrument. All contact forming instruments were used along with Palodent plus matrix system. PCT was measured using a digital force gauge before (T0), immediate post operative (T1) and at 3 (T2), 6 (T3), 9 (T4), and 12 months (T5) after restorative treatment. Using One-Way ANOVA, Tukey's post hoc test, and Bonferroni correction, PCT values were compared between groups before and after the intervention restoration. Meanwhile, for comparisons within groups, a paired t-test was conducted (p <= 0.05).Results Contact forming instruments combined with Palodent plus sectional matrix system achieved better PCT. Trimax led to a statistically considerable tighter proximal contacts than the other groups (p < 0.05). No statistically significant difference was found in PCT between Contact pro-2, Perform and Palodent plus sectional matrix system. By means of multivariate analysis, the PCT between both T0 and T1 were increased (p < 0.001) and then it decreased till T5.Conclusions The use of transparent contact forming instruments achieved greater PCT compared to Palodent sectional matrix system alone that gradually decreased throughout 12 months and reached the PCT between the natural teeth. Using Trimax system provided the tightest proximal contacts. Additionally, digital force gauge was confirmed as an inclusive and accurate method to quantify PCT.
引用
收藏
页数:10
相关论文
共 37 条
[11]   Current Strategies to Control Recurrent and Residual Caries with Resin Composite Restorations: Operator- and Material-Related Factors [J].
Elgezawi, Moataz ;
Haridy, Rasha ;
Abdalla, Moamen A. ;
Heck, Katrin ;
Draenert, Miriam ;
Kaisarly, Dalia .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (21)
[12]  
Gugnani Neeraj, 2011, Int J Clin Pediatr Dent, V4, P93, DOI 10.5005/jp-journals-10005-1089
[13]   The accuracy of clinician evaluation of interproximal contacts using different methods [J].
Hansen, Paul A. ;
Atwood, Ariel ;
Shanahan, Mallory ;
Beatty, Mark .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (02) :284-289
[14]  
Hinton O., 2021, Dent Update, V48, P733, DOI [10.12968/denu.2021.48.9.733, DOI 10.12968/DENU.2021.48.9.733]
[15]   Evaluation of biological changes at the proximal contacts between single-tooth implant-supported prosthesis and the adjacent natural teeth - An in vivo study [J].
Kandathilparambil, Maria Roseme ;
Nelluri, Vizaikumar Vasudha ;
Vayadadi, Bhanu Chander ;
Gajjam, Naveen Kumar .
JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2020, 20 (04) :378-386
[16]  
Kim Kyounghwa, 2008, [The Journal of Korean Academy of Prosthodontics, 대한치과보철학회지], V46, P553, DOI 10.4047/jkap.2008.46.6.553
[17]  
Klein F, 2002, AM J DENT, V15, P232
[18]  
Kumari Suchitra, 2023, J Conserv Dent, V26, P67, DOI 10.4103/jcd.jcd_403_22
[19]   The long-term effect of a composite resin restoration on proximal contact tightness [J].
Loomans, B. A. C. ;
Opdam, N. J. M. ;
Roeters, F. J. M. ;
Bronkhorst, E. M. ;
Plasschaert, A. J. M. .
JOURNAL OF DENTISTRY, 2007, 35 (02) :104-108
[20]   A randomized clinical trial on proximal contacts of posterior composites [J].
Loomans, BAC ;
Opdam, NJM ;
Roeters, FJM ;
Bronkhorst, EM ;
Burgersdijk, RCW ;
Dörfer, CE .
JOURNAL OF DENTISTRY, 2006, 34 (04) :292-297