Modeling and thermodynamic analysis of a novel combined cooling and power system composed of alkali metal thermal electric converter and looped multistage thermoacoustically-driven refrigerator

被引:4
作者
Guo, Xinru [1 ]
Guo, Yumin [1 ]
Wang, Jiangfeng [1 ]
Zhang, Guolutiao [1 ]
Wang, Ziyan [1 ]
Wu, Weifeng [1 ]
Wang, Shunsen [1 ]
Zhao, Pan [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Looped multistage thermoacoustic-driven; refrigerator; Alkali metal thermal electric converter; Performance characteristic; Optimal region; Sensitivity analysis; THERMOELECTRIC CONVERTER; PERFORMANCE EVALUATION; CONCEPTUAL DESIGN; OPERATION STATES; HYBRID SYSTEM; FUEL-CELL; GENERATOR; STRATEGIES; ENGINE;
D O I
10.1016/j.energy.2022.126016
中图分类号
O414.1 [热力学];
学科分类号
摘要
A large amount of high-quality heat from alkali metal thermal electric converter (AMTEC) is wasted, which greatly degrades its thermodynamic performance and causes serious thermal pollution. For solving this issue, a novel combined cooling and power (CCP) distributed system including two static energy conversion units, i.e., the AMTEC unit and looped multistage thermoacoustic-driven refrigerator (LMTADR) unit, is proposed. The general performance for the proposed system is analyzed via establishing the mathematical model, and the optimal region is obtained by considering both equivalent power density and exergy efficiency. Then, the parameter sensitive analysis is represented to provide some theoretical guidance for design of the proposed system. The results reveal that compared with a sole AMTEC system, the maximum equivalent power density and exergy efficiency of the combined system are improved by 42.4% and 22.5%, respectively. When the perfor-mance improvement rate reaches the maximum, the combined system achieves an equivalent power density of 9203.3 W m- 2, a cooling rate density of 3190.2 W m- 2 and an exergy efficiency of 25.8%. This study not only proves the superiority of AMTEC-LMTADR combined system, but also implies the extensive possibility of recovering medium and high-grade heat through LMTADR for refrigeration.
引用
收藏
页数:12
相关论文
共 45 条
  • [41] A cascade-looped thermoacoustic driven cryocooler with different-diameter resonance tubes. Part II: Experimental study and comparison
    Xu, Jingyuan
    Hu, Jianying
    Sun, Yanlei
    Wang, Huizhi
    Wu, Zhanghua
    Hu, Jiangfeng
    Hochgreb, Simone
    Luo, Ercang
    [J]. ENERGY, 2020, 207
  • [42] A cascade-looped thermoacoustic driven cryocooler with different-diameter resonance tubes. Part I: Theoretical analysis of thermodynamic performance and characteristics
    Xu, Jingyuan
    Hu, Jianying
    Luo, Ercang
    Zhang, Limin
    Dai, Wei
    [J]. ENERGY, 2019, 181 : 943 - 953
  • [43] A comprehensive review of solid oxide fuel cells operating on various promising alternative fuels
    Xu, Qidong
    Guo, Zengjia
    Xia, Lingchao
    Li, Zheng
    Bello, Idris Temitope
    Zheng, Keqing
    Ni, Meng
    He, Qijiao
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2022, 253
  • [44] Thermodynamic analysis of the AMTEC-based nuclear power system under time-varying characteristic of the lunar surface
    Zhang, Yi-Chen
    Hu, Yu-Peng
    Wang, Yi-Jun
    Xiang, Yan-Hua
    Zhu, Chang-Chun
    Hu, Shao-Quan
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (08) : 12344 - 12357
  • [45] Optimization of vapor anode multi-tube alkali metal thermoelectric converter based on an integrated model
    Zhu, Lei
    Jiang, Xinbiao
    Li, Huaqi
    Kang, Xiaoya
    Tian, Xiaoyan
    Chen, Sen
    Qiu, Suizheng
    [J]. APPLIED ENERGY, 2020, 259