Material decomposition with a prototype photon-counting detector CT system: expanding a stoichiometric dual-energy CT method via energy bin optimization and K-edge imaging
被引:4
|作者:
Richtsmeier, Devon
[1
]
Rodesch, Pierre-Antoine
[1
]
Iniewski, Kris
[2
]
Bazalova-Carter, Magdalena
[1
]
机构:
[1] Univ Victoria, Dept Phys & Astron, 3800 Finnerty Rd, Victoria, BC V8P 5C2, Canada
[2] Redlen Techol, 1763 Sean Hts, Saanichton, BC V8M 1X6, Canada
基金:
加拿大自然科学与工程研究理事会;
加拿大创新基金会;
关键词:
photon-counting detector CT;
dual-energy CT;
material decomposition;
EFFECTIVE ATOMIC NUMBERS;
X-RAY ATTENUATION;
ELECTRON-DENSITY;
COMPUTED-TOMOGRAPHY;
TISSUE SEGMENTATION;
EXPERIMENTAL-VERIFICATION;
SINGLE;
CALIBRATION;
PARAMETERIZATION;
FEASIBILITY;
D O I:
10.1088/1361-6560/ad25c8
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
Objective. Computed tomography (CT) has advanced since its inception, with breakthroughs such as dual-energy CT (DECT), which extracts additional information by acquiring two sets of data at different energies. As high-flux photon-counting detectors (PCDs) become available, PCD-CT is also becoming a reality. PCD-CT can acquire multi-energy data sets in a single scan by spectrally binning the incident x-ray beam. With this, K-edge imaging becomes possible, allowing high atomic number (high-Z) contrast materials to be distinguished and quantified. In this study, we demonstrated that DECT methods can be converted to PCD-CT systems by extending the method of Bourque et al (2014). We optimized the energy bins of the PCD for this purpose and expanded the capabilities by employing K-edge subtraction imaging to separate a high-atomic number contrast material. Approach. The method decomposes materials into their effective atomic number (Z eff) and electron density relative to water (rho e ). The model was calibrated and evaluated using tissue-equivalent materials from the RMI Gammex electron density phantom with known rho e values and elemental compositions. Theoretical Z eff values were found for the appropriate energy ranges using the elemental composition of the materials. Z eff varied slightly with energy but was considered a systematic error. An ex vivo bovine tissue sample was decomposed to evaluate the model further and was injected with gold chloride to demonstrate the separation of a K-edge contrast agent. Main results. The mean root mean squared percent errors on the extracted Z eff and rho e for PCD-CT were 0.76% and 0.72%, respectively and 1.77% and 1.98% for DECT. The tissue types in the ex vivo bovine tissue sample were also correctly identified after decomposition. Additionally, gold chloride was separated from the ex vivo tissue sample with K-edge imaging. Significance. PCD-CT offers the ability to employ DECT material decomposition methods, along with providing additional capabilities such as K-edge imaging.