Predictability of the Achieved Lenticule Thickness in Keratorefractive Lenticule Extraction for Myopia Correction

被引:6
作者
Bohac, Maja [1 ,3 ]
Gabric, Ivan [1 ]
Gabric, Kresimir [1 ]
Jagic, Mateja [1 ]
Mosquera, Samuel Arba [2 ]
机构
[1] Univ Rijeka, Specialty Eye Hosp Svjetlost, Sch Med, Zagreb, Croatia
[2] SCHWIND Eye Tech Solut, Kleinostheim, Germany
[3] Heinzelova 39, Zagreb 10000, Croatia
关键词
LASIK; REDUCTION; ARTEMIS; CORNEA; SMILE; IRREGULARITIES; ASTIGMATISM; OUTCOMES; READOUT; LENS;
D O I
10.3928/1081597X-20230925-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the predictability between the SCHWIND ATOS femtosecond laser (SCHWIND eye-tech-solutions) read-out and achieved lenticule thickness measured using MS-39 anterior segment optical coherence tomography (AS-OCT; CSO) at the corneal vertex at postoperative 1 day and 1 and 3 months of follow-up.METHODS: This retrospective case series included 130 eyes of 65 consecutive patients who were treated with SmartSight (SCHWIND eye-tech-solutions) lenticule extraction. Sixty-four percent of patients were women with a mean spherical refraction of-4.98 +/- 1.19 diopters (D) and mean astigmatism of 0.53 +/- 0.64 D. The measurements were performed using AS-OCT with the Phoenix Software v 4.1.1.5. Lenticule thick-ness was obtained by the subtraction method between preop-erative and postoperative total corneal thickness.RESULTS: A lower reduction in central corneal thickness (CCT) compared to the laser read-out for all three follow-up visits can be observed. Essentially, the reduction in CCT was identical at 3 months versus 1 month. The reduction in CCT was lowest at postoperative 1 day. Examining the 1-and 3-month data (essentially equivalent), one can see a best fit of y = 0.94 x-7 mu m.CONCLUSIONS: The reduction in CCT was stable from 1 month of follow-up. The stable reduction in CCT was-6% (-1.5% after accounting for design decisions) and-7 mu m lower than the respective laser read-out. The findings are predictable, showing a certain level of the lenticules becom-ing slightly thinner than their respective laser read-outs.
引用
收藏
页码:728 / 735
页数:8
相关论文
共 39 条
[1]   Analytical optimization of the cutting efficiency for generic cavitation bubbles [J].
Arba-Mosquera, Samuel ;
Naubereit, Pascal ;
Sobutas, Simas ;
Verma, Shwetabh .
BIOMEDICAL OPTICS EXPRESS, 2021, 12 (07) :3819-3835
[2]  
csoitalia, MS-39-CSO Italia
[3]  
de Ortueta D, 2007, J REFRACT SURG, V23, P198
[4]   Corneal stromal thickness changes after myopic laser cornea refractive surgery [J].
Del Barrio, Jorge L. Alio ;
Canto-Cerdan, Mario ;
El Bahrawy, Mohamed ;
Casanova, Laura ;
Garcia, Maria J. ;
Cavas, Francisco ;
Alio, Jorge L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (03) :334-341
[5]   EXCIMER-LASER ABLATION RATE AND CORNEAL HYDRATION [J].
DOUGHERTY, PJ ;
WELLISH, KL ;
MALONEY, RK .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (02) :169-176
[6]   First European results of a new refractive lenticular extraction procedure-SmartSight by SCHWIND eye-tech-solutions [J].
Gabric, Ivan ;
Bohac, Maja ;
Gabric, Kresimir ;
Arba Mosquera, Samuel .
EYE, 2023, 37 (18) :3768-3775
[7]   The Percent Volume Altered in Correction of Myopia and Myopic Astigmatism With PRK, LASIK, and SMILE [J].
Gatinel, Damien ;
Weyhausen, Andreas ;
Bischoff, Mark .
JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (12) :844-+
[8]   Low-density plasma formation in aqueous biological media using sub-nanosecond laser pulses [J].
Genc, Suzanne L. ;
Ma, Huan ;
Venugopalan, Vasan .
APPLIED PHYSICS LETTERS, 2014, 105 (06)
[9]   Risk profiles of ectasia after keratorefractive surgery [J].
Giri, Pushpanjali ;
Azar, Dimitri T. .
CURRENT OPINION IN OPHTHALMOLOGY, 2017, 28 (04) :337-342
[10]   Spectral OCT with speckle contrast reduction for evaluation of the healing process after PRK and transepithelial PRK [J].
Kaluzny, Bartlomiej J. ;
Szkulmowski, Maciej ;
Bukowska, Danuta M. ;
Wojtkowski, Maciej .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (04) :1089-1098