Low complexity adaptive ultrasound image beamformer combined with improved multiphase apodization with cross-correlation

被引:1
|
作者
Wang, Ping [1 ]
Chen, Jinghan [1 ]
Shen, Yue [1 ]
Li, Qianwen [1 ]
Tong, Lin [1 ]
Li, Xitao [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Sec, Chongqing 400044, Peoples R China
关键词
Ultrasound imaging; Low complexity adaptive; Phase apodization; Cross-correlation; DUAL APODIZATION; COHERENCE FACTOR; SPECKLE;
D O I
10.1016/j.ultras.2023.107084
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, an ultrasound imaging method combined with low-complexity adaptive beamformer (LCA) and improved multiphase apodization with cross-correlation (IMPAX) is proposed to improve image resolution and contrast with low hardware cost. Firstly, the delayed echo signal is apodized by the LCA to obtain a narrow mainlobe width echo signal and LCA output. Then, multiple pairs of complementary square-wave phase apodizations are applied to the apodized echo signal to obtain corresponding signal pairs, which are used to calculate the normalized cross-correlation (NCC) matrix. Finally, the average value of the NCC matrices is filtered by 2-D means, and the filtered result is introduced as the weighting factor for the LCA output. The simulation and experimental results show that the proposed LCA-IMPAX can effectively reduce the mainlobe width, suppress clutter, and be robust to noise. Compared with DAS, LCA, and MPAX, for simulated point targets, the full-width at half-maximum (FWHM, -6dB) of LCA-IMPAX is reduced by 49.22%, 10.06%, and 48.67%, respectively. For simulated cyst, the CR is improved by 219.91%, 138.08%, and 103.44%, respectively. For experimental cysts, the CR is improved by an average of 145.00%, 136.14%, and 55.09%, respectively. The results of human heart data indicate that LCA-IMPAX has good imaging quality in vivo. Since the proposed method does not involve covariance matrix inversion, it can be applied in real-time imaging systems.
引用
收藏
页数:13
相关论文
共 32 条
  • [1] A Low-Complexity Beamformer for Ultrasound Imaging Based on Sub-Beamformer and Multi-Apodization With Cross-Correlation
    Shen, Yue
    Wang, Ping
    Tong, Lin
    Chen, Jinghan
    Li, Qianwen
    Zhu, Jinchan
    Wang, Kunlin
    Zeng, Jingya
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (10): : 1551 - 1565
  • [2] Dual apodization with cross-correlation combined with robust Capon beamformer applied to ultrasound passive cavitation mapping
    Lu, Shukuan
    Li, Renyan
    Zhao, Yan
    Yu, Xianbo
    Wang, Diya
    Wan, Mingxi
    MEDICAL PHYSICS, 2020, 47 (05) : 2182 - 2196
  • [3] Performance Evaluation of Adaptive Imaging Based on Multiphase Apodization with Cross-correlation: A Pilot Study in Abdominal Ultrasound
    Shin, Junseob
    Chen, Yu
    Malhi, Harshawn
    Chen, Frank
    Yen, Jesse
    ULTRASONIC IMAGING, 2018, 40 (04) : 195 - 214
  • [4] Improved Image Quality Using Phase Aberration Correction and Dual Apodization with Cross-correlation
    Shin, Junseob
    Yen, Jesse T.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 393 - 396
  • [5] Multi-apodization with cross-correlation combined with generalized sidelobe canceller applied to ultrasound imaging
    Wang, Ping
    Shen, Yue
    Chen, Jinghan
    Li, Qianwen
    Tong, Lin
    Li, Xitao
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (03) : 1713 - 1731
  • [6] Clutter Suppression Using Phase Apodization with Cross-correlation in Ultrasound Imaging
    Shin, Junseob
    Yen, Jesse T.
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 785 - 788
  • [7] Sidelobe suppression in ultrasound imaging using dual apodization with cross-correlation
    Seo, Chi Hyung
    Yen, Jesse T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (10) : 2198 - 2210
  • [8] Synergistic Enhancements of Ultrasound Image Contrast With a Combination of Phase Aberration Correction and Dual Apodization With Cross-Correlation
    Shin, Junseob
    Yen, Jesse T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (09) : 2089 - 2101
  • [9] Fresnel Beamforming and Dual Apodization with Cross-Correlation for Curvilinear Arrays in Low-cost Portable Ultrasound System
    Nguyen, M.
    Shin, J.
    Yen, J.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2213 - 2216
  • [10] Passive cavitation mapping using dual apodization with cross-correlation in ultrasound therapy monitoring
    Lu, Shukuan
    Yu, Xianbo
    Li, Renyan
    Zong, Yujin
    Wan, Mingxi
    ULTRASONICS SONOCHEMISTRY, 2019, 54 : 18 - 31