The impact of biliary stents on the diagnostic yield of endoscopic ultrasound-guided fine needle aspiration for solid pancreatic lesions: A single-center retrospective study and meta-analysis
被引:1
|
作者:
Endo, Go
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, JapanUniv Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Endo, Go
[1
]
Ishigaki, Kazunaga
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Univ Tokyo Hosp, Dept Chemotherapy, Tokyo, JapanUniv Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Ishigaki, Kazunaga
[1
,2
]
Hamada, Tsuyoshi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, JapanUniv Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Hamada, Tsuyoshi
[1
]
Nakai, Yousuke
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Univ Tokyo Hosp, Dept Endoscopy & Endoscop Surg, 7-3-1 Hongo Bunkyo Ku, Tokyo 1138655, JapanUniv Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Nakai, Yousuke
[1
,3
]
Ishida, Kota
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, JapanUniv Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Ishida, Kota
[1
]
Kurihara, Kohei
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, JapanUniv Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Kurihara, Kohei
[1
]
论文数: 引用数:
h-index:
机构:
Tange, Shuichi
[1
]
论文数: 引用数:
h-index:
机构:
Takaoka, Shinya
[1
]
论文数: 引用数:
h-index:
机构:
Tokito, Yurie
[1
]
论文数: 引用数:
h-index:
机构:
Suzuki, Yukari
[1
]
论文数: 引用数:
h-index:
机构:
Oyama, Hiroki
[1
]
论文数: 引用数:
h-index:
机构:
Kanai, Sachiko
[1
,3
]
Suzuki, Tatsunori
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, JapanUniv Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Suzuki, Tatsunori
[1
]
Sato, Tatsuya
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, JapanUniv Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Sato, Tatsuya
[1
]
Hakuta, Ryunosuke
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, JapanUniv Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Hakuta, Ryunosuke
[1
]
Saito, Tomotaka
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, JapanUniv Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Saito, Tomotaka
[1
]
Takahara, Naminatsu
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, JapanUniv Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Takahara, Naminatsu
[1
]
Fujishiro, Mitsuhiro
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, JapanUniv Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
Fujishiro, Mitsuhiro
[1
]
机构:
[1] Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
[2] Univ Tokyo Hosp, Dept Chemotherapy, Tokyo, Japan
[3] Univ Tokyo Hosp, Dept Endoscopy & Endoscop Surg, 7-3-1 Hongo Bunkyo Ku, Tokyo 1138655, Japan
BackgroundEndoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is widely used for the pathological diagnosis of solid pancreatic lesions but in cases with obstructive jaundice, transpapillary sampling can be performed during endoscopic retrograde cholangiopancreatography with transpapillary biliary stent placement. Thus, it is still controversial whether EUS-FNA should be performed prior to endoscopic retrograde cholangiopancreatography with biliary stent placement or only after negative transpapillary sampling. MethodsThe accuracy, sensitivity, and specificity of EUS-FNA for solid pancreatic lesions with or without indwelling biliary stents were retrospectively studied in patients undergoing EUS-FNA between January 2017 and December 2021. We also conducted a meta-analysis including our data to compare the accuracy and sensitivity of EUS-FNA with or without biliary stents. ResultsA total of 509 patients (40 with biliary stents and 469 without biliary stents) were included. The accuracy (77.5% vs. 94.5%, p < 0.001) and sensitivity (71.0% vs. 91.7%, p < 0.001) were lower in EUS-FNA with biliary stents. A meta-analysis confirmed that accuracy (odds ratio [OR] of 0.43, 95% confidence interval [CI] 0.29-0.62, p < 0.001) and sensitivity (OR of 0.46, 95% CI 0.33-0.64, p < 0.001) were lower in EUS-FNA with biliary stents. There were no statistically significant differences between plastic stents and self-expandable metallic stents for accuracy or sensitivity. ConclusionsThe presence of biliary stents had a negative impact on the diagnostic performance of EUS-FNA, and EUS-FNA prior to endoscopic retrograde cholangiopancreatography with biliary stent placement should be considered in cases with obstructive jaundice.
机构:
Univ Oklahoma, Hlth Sci Ctr, Div Digest Dis & Nutr, Oklahoma City, OK 73117 USAUniv Oklahoma, Hlth Sci Ctr, Div Digest Dis & Nutr, Oklahoma City, OK 73117 USA
Madhoun, M. F.
Wani, S. B.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Colorado, Div Gastroenterol & Hepatol, Aurora, CO USAUniv Oklahoma, Hlth Sci Ctr, Div Digest Dis & Nutr, Oklahoma City, OK 73117 USA
Wani, S. B.
Rastogi, A.
论文数: 0引用数: 0
h-index: 0
机构:
Kansas City Vet Affairs Med Ctr, Div Gastroenterol & Hepatol, Kansas City, MO USAUniv Oklahoma, Hlth Sci Ctr, Div Digest Dis & Nutr, Oklahoma City, OK 73117 USA
Rastogi, A.
Early, D.
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Sch Med, Div Gastroenterol & Hepatol, St Louis, MO USAUniv Oklahoma, Hlth Sci Ctr, Div Digest Dis & Nutr, Oklahoma City, OK 73117 USA
Early, D.
Gaddam, S.
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Sch Med, Div Gastroenterol & Hepatol, St Louis, MO USAUniv Oklahoma, Hlth Sci Ctr, Div Digest Dis & Nutr, Oklahoma City, OK 73117 USA
Gaddam, S.
Tierney, W. M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Oklahoma, Hlth Sci Ctr, Div Digest Dis & Nutr, Oklahoma City, OK 73117 USAUniv Oklahoma, Hlth Sci Ctr, Div Digest Dis & Nutr, Oklahoma City, OK 73117 USA
Tierney, W. M.
Maple, J. T.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Oklahoma, Hlth Sci Ctr, Div Digest Dis & Nutr, Oklahoma City, OK 73117 USAUniv Oklahoma, Hlth Sci Ctr, Div Digest Dis & Nutr, Oklahoma City, OK 73117 USA