The evaluation of electrolyzed water, sodium dichloroisocyanurate, and peracetic acid with hydrogen peroxide for the disinfection of patient room surfaces

被引:3
作者
Solomon, Sadie [1 ,2 ]
Stachel, Anna [1 ]
Kelly, Anne [1 ]
Mraz, Joe [3 ]
Aguilar, Peter [3 ]
Gardner, Julia [2 ]
Mede, Judith [1 ]
Horrocks, Amy [2 ]
Sterling, Stephanie [1 ,4 ]
Aguero-Rosenfeld, Maria [5 ,6 ]
Phillips, Michael [1 ,4 ,7 ]
机构
[1] NYU Langone Hlth, Dept Infect Prevent & Control, New York, NY 10016 USA
[2] NYU Langone Hlth, Hosp Operat, New York, NY 10016 USA
[3] NYU Langone Hlth, Bldg Serv Dept, New York, NY 10016 USA
[4] NYU, Dept Med, Div Infect Dis, Grossman Sch Med, New York, NY USA
[5] NYU, Dept Pathol, Grossman Sch Med, New York, NY USA
[6] NYU Langone Hlth, Clin Labs, New York, NY 10016 USA
[7] NYU Langone Hlth, 545 First Ave, Greenberg Hall, SC1-132, New York, NY 10016 USA
关键词
Environmental surveillance; Patient room disinfection; Sporicidal disinfectant; Microbial sampling; EFFICACY; ENVIRONMENT; STANDARDS; BACTERIA; HYGIENE;
D O I
10.1016/j.ajic.2022.06.021
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Sporicidal disinfectants are necessary to control Clostridioides difficile and Candida auris. Novel application methods such as electrostatic sprayers may increase disinfection effectiveness. We employed a standardized protocol to assess 3 sporicidal disinfectants: electrolyzed water (EW), sodium dichloroisocya-nurate (NaDCC) and peracetic acid/hydrogen peroxide (PAA/H2O2).Methods: The study was conducted at 2 New York City hospitals (1,082 total beds) over an 18-month period. The 3 chemicals were applied by housekeeping personnel following the hospital protocol; the use of electro-static sprayers was incorporated into EW and NaDCC. In randomly selected rooms, 5 surfaces were sampled for microbial colony counts after cleaning. Data analyses were performed using negative binomial logistic regression.Results: We collected 774 samples. NaDCC-disinfected surfaces had a lower mean colony count (14 colony forming units [CFU]) compared to PAA/H2O2 (18 CFU, P = .36) and EW (37 CFU, P < .001). PAA/H2O2 and EW had more samples with any growth (both P < .05) compared to NaDCC. NaDCC applied with wipes and an electrostatic sprayer had the lowest number of samples with no growth and <2.5 CFU/cm2 (difference not significant).Conclusions: The use of NaDCC for surface disinfection resulted in the lowest bacterial colony counts on patient room high touch surfaces in our study.(c) 2022 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 30 条
[1]   Candida auris in Healthcare Facilities, New York, USA, 2013-2017 [J].
Adams, Eleanor ;
Quinn, Monica ;
Tsay, Sharon ;
Poirot, Eugenie ;
Chaturvedi, Sudha ;
Southwick, Karen ;
Greenko, Jane ;
Fernandez, Rafael ;
Kallen, Alex ;
Vallabhaneni, Snigdha ;
Haley, Valerie ;
Hutton, Brad ;
Blog, Debra ;
Lutterloh, Emily ;
Zucker, Howard .
EMERGING INFECTIOUS DISEASES, 2018, 24 (10) :1816-1824
[2]   How clean is clean? Proposed methods for hospital cleaning assessment [J].
Al-Hamad, A. ;
Maxwell, S. .
JOURNAL OF HOSPITAL INFECTION, 2008, 70 (04) :328-334
[3]  
[Anonymous], 2021, SAFETY DATA SHEET OX
[4]  
[Anonymous], 2020, CDC 4 ENV CLEANING P
[5]  
[Anonymous], 2021, SAFETY DATA SHEET PU
[6]  
BD Diagnostics, 2013, BD TRYP SOY AG 2 5 S
[7]   Sanitizer Efficacy against Murine Norovirus, a Surrogate for Human Norovirus, on Stainless Steel Surfaces when Using Three Application Methods [J].
Bolton, Stephanie L. ;
Kotwal, Grishma ;
Harrison, Mark A. ;
Law, S. Edward ;
Harrison, Judy A. ;
Cannon, Jennifer L. .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2013, 79 (04) :1368-1377
[8]   Prospective cluster controlled crossover trial to compare the impact of an improved hydrogen peroxide disinfectant and a quaternary ammonium-based disinfectant on surface contamination and health care outcomes [J].
Boyce, John M. ;
Guercia, Kerri A. ;
Sullivan, Linda ;
Havill, Nancy L. ;
Fekieta, Renee ;
Kozakiewicz, Janet ;
Goffman, David .
AMERICAN JOURNAL OF INFECTION CONTROL, 2017, 45 (09) :1006-1010
[9]   Improving Cleaning of the Environment Surrounding Patients in 36 Acute Care Hospitals [J].
Carling, Philip C. ;
Parry, Michael M. ;
Rupp, Mark E. ;
Po, John L. ;
Dick, Brian ;
Von Beheren, Sandra .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2008, 29 (11) :1035-1041
[10]  
Centers for Disease Control and Prevention, 2021, INF PREV CONTR CAN A